Literature DB >> 31240377

Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes.

Kazumasa Yamamura1, Yukihide Minoda2, Ryo Sugama1, Yoichi Ohta1, Suguru Nakamura1, Hideki Ueyama1, Hiroaki Nakamura1.   

Abstract

PURPOSE: The accuracy of patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) is still controversial, especially in the tibial prosthesis. It was hypothesized that the design modification of PSI improved the tibial prosthetic alignment and reduced the associated complications. The aim of this study was to compare the accuracy of a conventional PSI with that of a newly designed PSI for total knee arthroplasty (TKA) using a new three-dimensional (3D) measurement method.
METHODS: Thirty TKAs each using the conventional and newly designed PSIs were studied. The postoperative 3D-computed tomography (3D CT) image was superimposed on the preoperative 3D CT plan. The absolute differences in the tibial prosthetic alignment between the preoperative and postoperative 3D CT images were directly measured in the coronal, sagittal, and axial planes. Knees in which the difference in the prosthetic alignment was > 3° were considered deviations.
RESULTS: The new PSI showed less mean absolute differences and lower rate of deviations than the conventional PSI in the coronal and axial planes (p = 0.045 and p = 0.004, respectively). The deviations (> 3°) of the tibial prosthesis using the conventional PSI were 27, 30, and 63% and of those using the new PSI were 0, 20, and 20% in the coronal, sagittal, and axial planes, respectively.
CONCLUSIONS: This is the first report to evaluate the effect of improvement in PSI design on the postoperative alignment using 3D method, and it clearly showed that the modification significantly improved the accuracy of alignment and reduced the deviations. LEVEL OF EVIDENCE: Therapeutic study, case-control study, Level III.

Entities:  

Keywords:  Patient-specific instrumentation; Prosthetic alignment; Three-dimensional evaluation; Total knee arthroplasty

Year:  2019        PMID: 31240377     DOI: 10.1007/s00167-019-05571-7

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  33 in total

1.  The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction.

Authors:  M T Hirschmann; P Konala; F Amsler; F Iranpour; N F Friederich; J P Cobb
Journal:  J Bone Joint Surg Br       Date:  2011-05

2.  Tibial rotational alignment was significantly improved by use of a CT-navigated control device in total knee arthroplasty.

Authors:  Shinichi Kuriyama; Katsufumi Hyakuna; Satoshi Inoue; Yasuyuki Tamaki; Hiromu Ito; Shuichi Matsuda
Journal:  J Arthroplasty       Date:  2014-06-28       Impact factor: 4.757

3.  Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty.

Authors:  Shigetoshi Okamoto; Hideki Mizu-uchi; Ken Okazaki; Satoshi Hamai; Yasutaka Tashiro; Hiroyuki Nakahara; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-09       Impact factor: 4.342

4.  Computer-assisted total knee arthroplasty using patient-specific templating.

Authors:  M A Hafez; K L Chelule; B B Seedhom; K P Sherman
Journal:  Clin Orthop Relat Res       Date:  2006-03       Impact factor: 4.176

5.  Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.

Authors:  Werner Anderl; Leo Pauzenberger; Roman Kölblinger; Gabriele Kiesselbach; Georg Brandl; Brenda Laky; Bernhard Kriegleder; Philipp Heuberer; Eva Schwameis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-19       Impact factor: 4.342

6.  A multi-planar CT-based comparative analysis of patient-specific cutting guides with conventional instrumentation in total knee arthroplasty.

Authors:  Kanniraj Marimuthu; Darren B Chen; Ian A Harris; Emma Wheatley; Carl J Bryant; Samuel J MacDessi
Journal:  J Arthroplasty       Date:  2013-12-19       Impact factor: 4.757

7.  Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients.

Authors:  Stephen M Howell; Kyle Kuznik; Maury L Hull; Robert A Siston
Journal:  Orthopedics       Date:  2008-09       Impact factor: 1.390

8.  Patient-specific instrumentation improves tibial component rotation in TKA.

Authors:  Alcindo Silva; Ricardo Sampaio; Elisabete Pinto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-29       Impact factor: 4.342

9.  Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial.

Authors:  B Boonen; M G M Schotanus; B Kerens; W van der Weegen; R A M van Drumpt; N P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-09       Impact factor: 4.342

10.  Preliminary experience with the patient-specific templating total knee arthroplasty.

Authors:  Bert Boonen; Martijn G M Schotanus; Nanne P Kort
Journal:  Acta Orthop       Date:  2012-08-10       Impact factor: 3.717

View more
  4 in total

1.  Evaluation of the accuracy of resected bone thickness based on patient-specific instrumentation during total knee arthroplasty.

Authors:  Kazumasa Yamamura; Fumiaki Inori; Sadahiko Konishi
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-06       Impact factor: 3.067

2.  Finite element analysis of the tibial component alignment in a transverse plane in total knee arthroplasty.

Authors:  Roman Popescu; Stefan Cristea; Valentin Oleksik; Adrian Marius Pascu; Emil George Haritinian
Journal:  J Appl Biomed       Date:  2021-09-20       Impact factor: 1.797

3.  Patient-specific instrumentation combined with a new tool for gap balancing is useful in total knee replacement: a 3-year follow-up of a retrospective study.

Authors:  Ting Deng; Tangyou Liu; Qing Lei; Lihong Cai; Song Chen
Journal:  J Orthop Surg Res       Date:  2021-05-12       Impact factor: 2.359

4.  Surgeon Dominated Design Can Improve the Accuracy of Patient-Specific Instruments in Kinematically Aligned TKA.

Authors:  Liang Wen; Zhiwei Wang; Desi Ma; Tiebing Qu
Journal:  J Pers Med       Date:  2022-07-22
  4 in total