Literature DB >> 31175501

Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.

M Sanders1, S Servaas1, C Slagt2.   

Abstract

Cardiac output monitoring is used in critically ill and high-risk surgical patients. Intermittent pulmonary artery thermodilution and transpulmonary thermodilution, considered the gold standard, are invasive and linked to complications. Therefore, many non-invasive cardiac output devices have been developed and studied. One of those is electrical cardiometry. The results of validation studies are conflicting, which emphasize the need for definitive validation of accuracy and precision. We performed a database search of PubMed, Embase, Web of Science and the Cochrane Library of Clinical Trials to identify studies comparing cardiac output measurement by electrical cardiometry and a reference method. Pooled bias, limits of agreement (LoA) and mean percentage error (MPE) were calculated using a random-effects model. A pooled MPE of less than 30% was considered clinically acceptable. A total of 13 studies in adults (620 patients) and 11 studies in pediatrics (603 patients) were included. For adults, pooled bias was 0.03 L min-1 [95% CI - 0.23; 0.29], LoA - 2.78 to 2.84 L min-1 and MPE 48.0%. For pediatrics, pooled bias was - 0.02 L min-1 [95% CI - 0.09; 0.05], LoA - 1.22 to 1.18 L min-1 and MPE 42.0%. Inter-study heterogeneity was high for both adults (I2 = 93%, p < 0.0001) and pediatrics (I2 = 86%, p < 0.0001). Despite the low bias for both adults and pediatrics, the MPE was not clinically acceptable. Electrical cardiometry cannot replace thermodilution and transthoracic echocardiography for the measurement of absolute cardiac output values. Future research should explore it's clinical use and indications.

Entities:  

Keywords:  Bioimpedance; Cardiac output; Electrical cardiometry; Electrical velocimetry; Hemodynamic monitoring; Meta-analysis; Non-invasive; Systematic review

Mesh:

Year:  2019        PMID: 31175501      PMCID: PMC7205855          DOI: 10.1007/s10877-019-00330-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  88 in total

Review 1.  Measuring inconsistency in meta-analyses.

Authors:  Julian P T Higgins; Simon G Thompson; Jonathan J Deeks; Douglas G Altman
Journal:  BMJ       Date:  2003-09-06

2.  A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery.

Authors:  O Broch; J Renner; M Gruenewald; P Meybohm; J Schöttler; A Caliebe; M Steinfath; M Malbrain; B Bein
Journal:  Anaesthesia       Date:  2012-02-11       Impact factor: 6.955

3.  The use of electrical cardiometry for continuous cardiac output monitoring in preterm neonates: a validation study.

Authors:  R Song; W Rich; J H Kim; N N Finer; A C Katheria
Journal:  Am J Perinatol       Date:  2014-03-28       Impact factor: 1.862

4.  Agreement between methods of measurement with multiple observations per individual.

Authors:  J Martin Bland; Douglas G Altman
Journal:  J Biopharm Stat       Date:  2007       Impact factor: 1.051

5.  Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients.

Authors:  Wieland Raue; Marc Swierzy; Gerold Koplin; Wolfgang Schwenk
Journal:  Eur J Anaesthesiol       Date:  2009-12       Impact factor: 4.330

6.  Assessment of trending ability of cardiac output monitors by polar plot methodology.

Authors:  Lester A Critchley; Xiao X Yang; Anna Lee
Journal:  J Cardiothorac Vasc Anesth       Date:  2011-03-17       Impact factor: 2.628

7.  Stroke volume and cardiac output evaluation by electrical cardiometry: accuracy and reference nomograms in hemodynamically stable preterm neonates.

Authors:  A Boet; G Jourdain; S Demontoux; D De Luca
Journal:  J Perinatol       Date:  2016-04-21       Impact factor: 2.521

8.  Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery.

Authors:  Oswin Grollmuss; Serge Demontoux; André Capderou; Alain Serraf; Emre Belli
Journal:  Intensive Care Med       Date:  2012-03-30       Impact factor: 17.440

9.  Evaluation of the Aesculon cardiac output monitor by subxiphoidal Doppler flow measurement in children with congenital heart defects.

Authors:  Maren Tomaske; Walter Knirsch; Oliver Kretschmar; Christian Balmer; Katja Woitzek; Achim Schmitz; Urs Bauersfeld; Markus Weiss
Journal:  Eur J Anaesthesiol       Date:  2009-05       Impact factor: 4.330

10.  Clinical review: Goal-directed therapy-what is the evidence in surgical patients? The effect on different risk groups.

Authors:  Maurizio Cecconi; Carlos Corredor; Nishkantha Arulkumaran; Gihan Abuella; Jonathan Ball; R Michael Grounds; Mark Hamilton; Andrew Rhodes
Journal:  Crit Care       Date:  2013-03-05       Impact factor: 9.097

View more
  15 in total

Review 1.  [Hemodynamic monitoring in pediatric anesthesia].

Authors:  Andreas Otte; Ehrenfried Schindler; Claudia Neumann
Journal:  Anaesthesiologie       Date:  2022-05-23

2.  Improved Exercise Tolerance, Oxygen Delivery, and Oxygen Utilization After Transcatheter Aortic Valve Implantation for Severe Aortic Stenosis.

Authors:  Mélanie Suppan; Gleicy Barcelos; Stéphane Luise; John Diaper; Angela Frei; Christoph Ellenberger; Dionysios Adamopoulos; Stéphane Noble; Marc Licker
Journal:  CJC Open       Date:  2020-06-17

3.  Bioreactance-derived haemodynamic parameters in the transitional phase in preterm neonates: a longitudinal study.

Authors:  Lizelle Van Wyk; Johan Smith; John Lawrenson; Carl J Lombard; Willem Pieter de Boode
Journal:  J Clin Monit Comput       Date:  2021-05-13       Impact factor: 1.977

4.  The role of the maximal first derivative of the radial pulse wave (Rad dP/dtmax) in monitoring cardiac function.

Authors:  Hao Guo; Jing Zhou; Zhi Wang; Li-Kun Liu; Shu-Zhen Yu; Hong-Wei Cai
Journal:  J Thorac Dis       Date:  2020-05       Impact factor: 2.895

5.  Continuous Non-Invasive Cardiac Output: Myth or Reality.

Authors:  João Manoel Rossi Neto
Journal:  Arq Bras Cardiol       Date:  2019-09-02       Impact factor: 2.000

Review 6.  Non-invasive Cardiac Output Monitoring in Neonates.

Authors:  Roisin O'Neill; Eugene M Dempsey; Aisling A Garvey; Christoph E Schwarz
Journal:  Front Pediatr       Date:  2021-01-28       Impact factor: 3.418

7.  Development of in-airway laser absorption spectroscopy for respiratory based measurements of cardiac output.

Authors:  Nicholas M J Smith; John Couper; Graham Richmond; Dominic Sandhu; Gus Hancock; Peter A Robbins; Grant A D Ritchie
Journal:  Sci Rep       Date:  2021-03-04       Impact factor: 4.379

8.  Electrocardiometry for Hemodynamic Categorization and Assessment of Fluid Responsiveness in Pediatric Septic Shock: A Pilot Observational Study.

Authors:  Swathi S Rao; A V Lalitha; Mounika Reddy; Santu Ghosh
Journal:  Indian J Crit Care Med       Date:  2021-02

9.  Case Report: Anesthetic Management and Electrical Cardiometry as Intensive Hemodynamic Monitoring During Cheiloplasty in an Infant With Enzyme-Replaced Pompe Disease and Preserved Preoperative Cardiac Function.

Authors:  Meng-Chen Liu; Ming-Tse Wang; Philip Kuo-Ting Chen; Dau-Ming Niu; Yu-Hsuan Fan Chiang; Ming-Hui Hsieh; Hsiao-Chien Tsai
Journal:  Front Pediatr       Date:  2021-12-13       Impact factor: 3.418

10.  The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children-A prospective observational study.

Authors:  Frank Weber; Bharat K Rashmi; Gülhan Karaoz-Bulut; Jaap Dogger; Iris J de Heer; Christopher Prasser
Journal:  Paediatr Anaesth       Date:  2020-08-29       Impact factor: 2.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.