Literature DB >> 24683072

The use of electrical cardiometry for continuous cardiac output monitoring in preterm neonates: a validation study.

R Song1, W Rich1, J H Kim1, N N Finer1, A C Katheria2.   

Abstract

BACKGROUND: Electrical cardiometry (EC) is a continuous noninvasive method for measuring cardiac output (CO), but there are limited data on premature infants. We evaluated the utility of EC monitoring by comparing the results obtained using EC to measurements of CO and systemic blood flow using echocardiography (ECHO).
METHODS: In this prospective observational study, 40 preterm neonates underwent 108-paired EC and ECHO measurements.
RESULTS: There were correlations between EC-CO and left ventricular output (LVO, p < 0.005) and right ventricular output (RVO, p < 0.005) but not with superior vena cava (r = 0.093, p = 0.177). Both RVO and LVO correlated with EC with and without a hemodynamically significant ductus arteriosus (p = 0.001 and 0.008, respectively). The level of agreement was decreased in infants ventilated by high-frequency oscillation ventilators (HFOV). The bias in HFOV was also positive compared with the negative biases found in other modes of ventilation.
CONCLUSION: Given the correlation of EC with LVO, RVO, and lack of confounding effects of the ductus, our results suggest that EC has promise for trending CO in the preterm infant. However, given the limitations with mode of ventilation and the lack of correlation at low LVO values, further study is needed before this technology can be for routine use. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2014        PMID: 24683072     DOI: 10.1055/s-0034-1371707

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  18 in total

Review 1.  Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis.

Authors:  Koichi Suehiro; Alexandre Joosten; Linda Suk-Ling Murphy; Olivier Desebbe; Brenton Alexander; Sang-Hyun Kim; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

2.  Does obesity affect the non-invasive measurement of cardiac output performed by electrical cardiometry in children and adolescents?

Authors:  Luis Altamirano-Diaz; Eva Welisch; Ralf Rauch; Michael Miller; Teresa Sohee Park; Kambiz Norozi
Journal:  J Clin Monit Comput       Date:  2017-02-17       Impact factor: 2.502

3.  Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.

Authors:  M Sanders; S Servaas; C Slagt
Journal:  J Clin Monit Comput       Date:  2019-06-07       Impact factor: 2.502

4.  Thoracic fluid content by electric bioimpedance correlates with respiratory distress in newborns.

Authors:  G Paviotti; A De Cunto; V Moressa; C Bettiol; S Demarini
Journal:  J Perinatol       Date:  2017-07-27       Impact factor: 2.521

5.  Stroke volume and cardiac output evaluation by electrical cardiometry: accuracy and reference nomograms in hemodynamically stable preterm neonates.

Authors:  A Boet; G Jourdain; S Demontoux; D De Luca
Journal:  J Perinatol       Date:  2016-04-21       Impact factor: 2.521

6.  Hemodynamic reference for neonates of different age and weight: a pilot study with electrical cardiometry.

Authors:  K-H Hsu; T-W Wu; Y-C Wang; W-H Lim; C-C Lee; R Lien
Journal:  J Perinatol       Date:  2016-02-18       Impact factor: 2.521

7.  Electrical velocimetry for non-invasive monitoring of the closure of the ductus arteriosus in preterm infants.

Authors:  Ana Rodríguez Sánchez de la Blanca; M Sánchez Luna; N González Pacheco; M Arriaga Redondo; N Navarro Patiño
Journal:  Eur J Pediatr       Date:  2017-12-08       Impact factor: 3.183

8.  Umbilical Cord Milking Versus Delayed Cord Clamping in Preterm Infants.

Authors:  Anup C Katheria; Giang Truong; Larry Cousins; Bryan Oshiro; Neil N Finer
Journal:  Pediatrics       Date:  2015-07       Impact factor: 7.124

Review 9.  Challenges in Treating Low Blood Pressure in Preterm Infants.

Authors:  Eugene M Dempsey
Journal:  Children (Basel)       Date:  2015-06-15

Review 10.  Advances in Diagnosis and Management of Hemodynamic Instability in Neonatal Shock.

Authors:  Yogen Singh; Anup C Katheria; Farha Vora
Journal:  Front Pediatr       Date:  2018-01-19       Impact factor: 3.418

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.