BACKGROUND AND OBJECTIVE: To evaluate the noninvasive electrical velocimetry (Aesculon) monitor for cardiac output (CO) by subxiphoidal Doppler flow measurement in children. METHODS: CO was determined at the end of diagnostic or interventional cardiac catheterization for congenital heart defects. Standard ECG surface electrodes were attached in a vertical direction to the patients' left middle and lower neck, and lower thorax at the level of the heart and xiphoid process. Aesculon CO data were compared with a simultaneously measured CO by the subxiphoidal Doppler flow measurement technique. For each patient, measurements were repeated three times within 5 min. Whitney U-test, simple regression and Bland-Altman analysis were performed to compare CO values obtained by the two techniques. Data are given as range (median). RESULTS: A total of 36 children aged 5.7 (0.5-16.0) years were investigated. CO values obtained by Aesculon monitor [0.55-5.58 (2.62) l min] and subxiphoidal Doppler flow measurements [0.62-6.27 (3.05) l min] differed significantly between both methods (P = 0.04). Simple regression analysis revealed moderate correlation between CO values obtained from the two techniques (r = 0.5544, P < 0.001). Bias between the two methods was 0.31 l min with a precision of 1.92 l min. CONCLUSION: We conclude that electrical velocimetry using the Aesculon monitor does not reliably reflect absolute CO values as compared with subxiphoidal Doppler flow measurement.
BACKGROUND AND OBJECTIVE: To evaluate the noninvasive electrical velocimetry (Aesculon) monitor for cardiac output (CO) by subxiphoidal Doppler flow measurement in children. METHODS: CO was determined at the end of diagnostic or interventional cardiac catheterization for congenital heart defects. Standard ECG surface electrodes were attached in a vertical direction to the patients' left middle and lower neck, and lower thorax at the level of the heart and xiphoid process. Aesculon CO data were compared with a simultaneously measured CO by the subxiphoidal Doppler flow measurement technique. For each patient, measurements were repeated three times within 5 min. Whitney U-test, simple regression and Bland-Altman analysis were performed to compare CO values obtained by the two techniques. Data are given as range (median). RESULTS: A total of 36 children aged 5.7 (0.5-16.0) years were investigated. CO values obtained by Aesculon monitor [0.55-5.58 (2.62) l min] and subxiphoidal Doppler flow measurements [0.62-6.27 (3.05) l min] differed significantly between both methods (P = 0.04). Simple regression analysis revealed moderate correlation between CO values obtained from the two techniques (r = 0.5544, P < 0.001). Bias between the two methods was 0.31 l min with a precision of 1.92 l min. CONCLUSION: We conclude that electrical velocimetry using the Aesculon monitor does not reliably reflect absolute CO values as compared with subxiphoidal Doppler flow measurement.
Authors: Frederik Trinkmann; Manuel Berger; Ursula Hoffmann; Martin Borggrefe; Jens J Kaden; Joachim Saur Journal: Clin Res Cardiol Date: 2011-07-01 Impact factor: 5.460
Authors: Frederik Trinkmann; Manuel Berger; Christina Doesch; Theano Papavassiliu; Stefan O Schoenberg; Martin Borggrefe; Jens J Kaden; Joachim Saur Journal: J Clin Monit Comput Date: 2015-06-27 Impact factor: 2.502
Authors: Martin Ernst Blohm; Jana Hartwich; Denise Obrecht; Jan Felix Kersten; Dominique Singer Journal: J Clin Monit Comput Date: 2016-04-12 Impact factor: 2.502
Authors: Garry M Steil; Olive S Eckstein; Julie Caplow; Michael S D Agus; Brian K Walsh; Jackson Wong Journal: J Clin Monit Comput Date: 2011-06-21 Impact factor: 2.502