| Literature DB >> 31159533 |
Manasa Gaddam1, Sameer Sethi1, Aditi Jain1, Vikas Saini1.
Abstract
BACKGROUND: Air-QⓇ laryngeal mask airway (LMA) is a second-generation supraglottic airway device (SAD) providing adequate airway control despite the unfavorable airway anatomy in children. Several studies have assessed it as a conduit for tracheal intubation and compared its efficacy with that of other SADs, but there are no studies comparing the laryngeal view with midline and rotational insertion techniques of Air-Q. Therefore, this study compared the fiber-optic bronchoscopic (FOB) assessment of the Air-Q position using these two insertion techniques.Entities:
Keywords: Air-QⓇ; Complications; Insertion techniques; Laryngeal mask airway; Laryngeal view; Supraglottic airway
Year: 2019 PMID: 31159533 PMCID: PMC6900414 DOI: 10.4097/kja.d.18.00367
Source DB: PubMed Journal: Korean J Anesthesiol ISSN: 2005-6419
Fig. 1.Air-QⓇ laryngeal mask airway.
Demographic Data
| Characteristics | Classic midline technique | Rotational technique | P value |
|---|---|---|---|
| Age (yr) | 7.6 ± 2.3 | 7.4 ± 1.9 | 0.675 |
| Weight (kg) | 17.5 ± 3.3 | 18.3 ± 3.5 | 0.529 |
| Sex (M/F) | 19/21 | 29/11 | 0.653 |
| Air-Q sizes (1.5/2) | 15/25 | 14/26 | 0.816 |
Values are presented as mean ± SD or numbers, analyzed using the independent t-test. The values presented in ratios were analyzed using the chi square test.
Fig. 2.CONSORT flow diagram showing 80 children randomly allocated into classic midline and rotational technique groups.
Characteristics of the Device
| Classic midline technique | Rotational technique | P value | |
|---|---|---|---|
| FOB Grade 1 | 19 | 29 | 0.045[ |
| FOB Grade 2 | 13 | 10 | |
| FOB Grade 3 | 6 | 1 | |
| FOB Grade 4 | 0 | 0 | |
| FOB Grade 5 | 2 | 0 | |
| FOB Grading 1 + 2 (Optimal position) | 32 | 39 | 0.044[ |
| Time taken to insert the device (s) | 10.2 ± 2.1 | 7.2 ± 1.5 | < 0.001[ |
| Number of attempts | |||
| 1st attempt | 32 (80) | 38 (95) | 0.105[ |
| 2nd attempt | 6 (15) | 2 (5) | |
| Alternate approach used | 2 (5) | 0 | |
| Ease of insertion | |||
| Easy | 32 (80) | 38 (95) | 0.105[ |
| Moderate | 6 (15) | 2 (5) | |
| Difficult | 2 (5) | ||
| OPLP | 22.6 ± 1.8 | 23.3 ± 1.4 | 0.720[ |
Values are presented as mean ± SD or numbers (%). P < 0.05 = Significant;
Chi square test,
Unpaired t-test,
Fischer exact test.
FOB: fiberoptic bronchoscopy, OPLP: oropharyngeal leak pressure.
Complications after Removal of Device
| Classic midline technique | Rotational technique | P value | |
|---|---|---|---|
| Blood on the device | 2/40 (5) | 1/40 (2.5) | 0.640 |
| Larynogospasm | 2/40 (5) | 0/40 | 0.152 |
| Desaturation | 0 | 0 |
Values are presented as numbers (%), analyzed using the Fischer exact test.