Literature DB >> 21973052

Evaluation of air-Q™ intubating laryngeal airway as a conduit for tracheal intubation in infants--a pilot study.

Renu Sinha1, Bikash Ranjan Ray.   

Abstract

BACKGROUND: Air-Q™ intubating laryngeal airway (ILA) has been used successfully as a conduit for tracheal intubation in pediatric difficult airway. However, its use as an airway device and conduit for intubation in infants is not yet evaluated. AIMS: The primary objective was to evaluate ILA as a conduit for tracheal intubation in infants, and secondary objectives were to evaluate ILA in terms of ease of insertion and ventilation, oropharyngeal leak pressure (OLP), glottic view, and complications.
METHODS: Twenty infants with normal airway were included. After induction of general anesthesia and neuromuscular blockade, ILA (size 1.0/1.5) was inserted. Fiberoptic bronchoscope (FOB)-guided intubation and removal of ILA with the stabilizing stylet was attempted.
RESULTS: The mean age and weight of the infants were 7.5 ± 2.3 months and 7.3 ± 1.8 kg. The ILA sizes 1.0 and 1.5 were inserted in 10 infants each according to the weight of the infants. The mean OLP was 18.5 ± 1.8 cm H₂O, and mean time for insertion of ILA was 13.3 ± 3.9 s. Glottic view was grade I in 6, grade II in 1, grade III in 4, and grade IV in nine infants. Tracheal intubation was successful in 19/20 infants. The mean endotracheal tube (ETT) insertion time and mean total time (ILA insertion to the confirmation of ETT placement) were 95.6 ± 32.3 s and 306.42 ± 120.2 s respectively.
CONCLUSION: The ILA is a safe and easy-to-use supraglottic airway device for intubation with FOB in infants with normal airway. Insertion and removal of ILA are easy with satisfactory oropharyngeal seal and ventilation.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 21973052     DOI: 10.1111/j.1460-9592.2011.03710.x

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  9 in total

1.  Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients.

Authors:  Karim K Girgis; Maha M I Youssef; Nashwa S ElZayyat
Journal:  Saudi J Anaesth       Date:  2014-10

Review 2.  Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis.

Authors:  Eun Jin Ahn; Geun Joo Choi; Hyun Kang; Chong Wha Baek; Yong Hun Jung; Young Cheol Woo; Si Ra Bang
Journal:  Biomed Res Int       Date:  2016-06-23       Impact factor: 3.411

3.  A two-stage approach to induction and intubation of two infants with Pierre Robin Sequence using a LMA Classic™ and Air-Q®: two cases report.

Authors:  T Wesley Templeton; Yvon F Bryan
Journal:  Korean J Anesthesiol       Date:  2016-07-01

Review 4.  Anesthesiological risks in mucopolysaccharidoses.

Authors:  Alessandra Moretto; Maria Grazia Bosatra; Laura Marchesini; Simonetta Tesoro
Journal:  Ital J Pediatr       Date:  2018-11-16       Impact factor: 2.638

5.  Comparison of Air-QⓇ insertion techniques in pediatric patients with fiber-optic bronchoscopic assessment: a prospective randomized control trial.

Authors:  Manasa Gaddam; Sameer Sethi; Aditi Jain; Vikas Saini
Journal:  Korean J Anesthesiol       Date:  2019-06-04

6.  Supraglottic Airway Devices for Elective Pediatric Anesthesia: I-gel versus Air-Q, Which is the Best?

Authors:  Rami Mounir Wahba; Milad Zekry Ragaei; Ayman Anis Metry; George Mikhael Nakhla
Journal:  Anesth Essays Res       Date:  2021-03-22

7.  Pediatric airway management.

Authors:  Jeff Harless; Ramesh Ramaiah; Sanjay M Bhananker
Journal:  Int J Crit Illn Inj Sci       Date:  2014-01

Review 8.  Small is the new big: An overview of newer supraglottic airways for children.

Authors:  Rakhee Goyal
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2015 Oct-Dec

9.  Pediatric supraglottic airway devices in clinical practice: A prospective observational study.

Authors:  Maren Kleine-Brueggeney; Anne Gottfried; Sabine Nabecker; Robert Greif; Malte Book; Lorenz Theiler
Journal:  BMC Anesthesiol       Date:  2017-09-02       Impact factor: 2.217

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.