Literature DB >> 31145920

A flow-through cell counting assay for point-of-care enumeration of CD4 T-cells.

Simon Bystryak1, Rajiv P Bandwar2, Rasa Santockyte2.   

Abstract

CD4 T-cell count is a priority for staging HIV disease and guiding clinical management as part of HIV care. Conventional CD4 T-cell enumeration methods based on flow cytometry are expensive, require well-trained personnel, and are challenging to use in rural, resource-scarce areas. A simple CD4 T-cell count test that can be used at point-of care, the Flow-Through cell Counting Assay (FTCA), is described in this article. The FTCA is based on the use of: 1) a special membrane that selectively retains white blood cells (WBCs); 2) a sample delivery system; and 3) optical signal detection. To show the feasibility of the FTCA, a proof-of-concept prototype of the FTCA cassette and digital camera or handheld reflectance meter were used for obtaining quantitative assay results within 30 min. The results show that the FTCA allows for quantitative enumeration of CD4 T-cells in the clinically relevant range of CD4 T-cell concentrations. The advantages of the FTCA technology, including simplicity, short analysis time, and portability, suggest that FTCA has great potential for use in clinical practice and wide applicability for other cell-based diagnostic tests.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  CD4 count; Flow-through assay; HIV; Leukoreduction filter; Point-of-care

Mesh:

Year:  2019        PMID: 31145920      PMCID: PMC6626576          DOI: 10.1016/j.jviromet.2019.05.012

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  35 in total

1.  Effect of point-of-care CD4 cell count tests on retention of patients and rates of antiretroviral therapy initiation in primary health clinics: an observational cohort study.

Authors:  Ilesh V Jani; Nádia E Sitoe; Eunice R Alfai; Patrina L Chongo; Jorge I Quevedo; Beatriz M Rocha; Jonathan D Lehe; Trevor F Peter
Journal:  Lancet       Date:  2011-09-25       Impact factor: 79.321

2.  Determination of CD4 antigen density on cells: role of antibody valency, avidity, clones, and conjugation.

Authors:  K A Davis; B Abrams; S B Iyer; R A Hoffman; J E Bishop
Journal:  Cytometry       Date:  1998-10-01

3.  Rapid, label-free CD4 testing using a smartphone compatible device.

Authors:  Manoj Kumar Kanakasabapathy; Hardik J Pandya; Mohamed Shehata Draz; Manjyot Kaur Chug; Magesh Sadasivam; Shreya Kumar; Behzad Etemad; Vinish Yogesh; Mohammadali Safavieh; Waseem Asghar; Jonathan Z Li; Athe M Tsibris; Daniel R Kuritzkes; Hadi Shafiee
Journal:  Lab Chip       Date:  2017-08-22       Impact factor: 6.799

4.  A flow-through cell counting assay for point-of-care enumeration of CD4 T-cells.

Authors:  Simon Bystryak; Rajiv P Bandwar; Rasa Santockyte
Journal:  J Virol Methods       Date:  2019-05-28       Impact factor: 2.014

5.  Laboratory-based performance evaluation of PIMA CD4+ T-lymphocyte count point-of-care by lay-counselors in Kenya.

Authors:  Clement Zeh; Charles E Rose; Seth Inzaule; Mitesh A Desai; Fredrick Otieno; Felix Humwa; Benta Akoth; Paul Omolo; Robert T Chen; Yenew Kebede; Taraz Samandari
Journal:  J Immunol Methods       Date:  2017-05-18       Impact factor: 2.303

6.  Near patient CD4 count in a hospitalized HIV patient population.

Authors:  Monique Givens; Amanda Weaver; Sarah Bickman; Cathy Logan; Emilia V Noormahomed; Sam Patel; Robert T Schooley; Constance A Benson; Michael J Lochhead
Journal:  Cytometry B Clin Cytom       Date:  2015-05-27       Impact factor: 3.058

Review 7.  CD4 counting technologies for HIV therapy monitoring in resource-poor settings--state-of-the-art and emerging microtechnologies.

Authors:  Macdara T Glynn; David J Kinahan; Jens Ducrée
Journal:  Lab Chip       Date:  2013-07-21       Impact factor: 6.799

Review 8.  The evolving role of CD4 cell counts in HIV care.

Authors:  Nathan Ford; Graeme Meintjes; Marco Vitoria; Greg Greene; Tom Chiller
Journal:  Curr Opin HIV AIDS       Date:  2017-03       Impact factor: 4.283

Review 9.  CD4 enumeration technologies: a systematic review of test performance for determining eligibility for antiretroviral therapy.

Authors:  Rosanna W Peeling; Kimberly A Sollis; Sarah Glover; Suzanne M Crowe; Alan L Landay; Ben Cheng; David Barnett; Thomas N Denny; Thomas J Spira; Wendy S Stevens; Siobhan Crowley; Shaffiq Essajee; Marco Vitoria; Nathan Ford
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

10.  Is it still worthwhile to perform quarterly cd4+ t lymphocyte cell counts on hiv-1 infected stable patients?

Authors:  Antonio Di Biagio; Marta Ameri; Davide Sirello; Giovanni Cenderello; Enrico Di Bella; Lucia Taramasso; Barbara Giannini; Mauro Giacomini; Claudio Viscoli; Giovanni Cassola; Marcello Montefiori
Journal:  BMC Infect Dis       Date:  2017-02-06       Impact factor: 3.090

View more
  4 in total

1.  A flow-through cell counting assay for point-of-care enumeration of CD4 T-cells.

Authors:  Simon Bystryak; Rajiv P Bandwar; Rasa Santockyte
Journal:  J Virol Methods       Date:  2019-05-28       Impact factor: 2.014

2.  Establishment and Clinical Application of a Method for Detecting T Lymphocyte Subsets by Cellular Immunochip Technology.

Authors:  Chen Chen; Yan-Mei Liu; Shu-Xia Xuan; Mei-Fang Zhou; Peng Zhou; Bin Cheng; Jin-Duan Lin; Wei-Guo Yin; Lin-Hai Li
Journal:  J Inflamm Res       Date:  2021-12-31

3.  Microparticle-tagged image-based cell counting (ImmunoSpin) for CD4 + T cells.

Authors:  Sang-Hyun Hwang; John Jeongseok Yang; Yoon-Hee Oh; Dae-Hyun Ko; Heungsup Sung; Young-Uk Cho; Seongsoo Jang; Chan-Jeoung Park; Heung-Bum Oh
Journal:  Mikrochim Acta       Date:  2021-11-25       Impact factor: 5.833

4.  An inkjet-printed polysaccharide matrix for on-chip sample preparation in point-of-care cell counting chambers.

Authors:  Xichen Zhang; Dorothee Wasserberg; Christian Breukers; Bridgette J Connell; Pauline J Schipper; Joost van Dalum; Ellen Baeten; Dorine van den Blink; Andries C Bloem; Monique Nijhuis; Annemarie M J Wensing; Leon W M M Terstappen; Markus Beck
Journal:  RSC Adv       Date:  2020-05-12       Impact factor: 3.361

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.