Literature DB >> 23670110

CD4 counting technologies for HIV therapy monitoring in resource-poor settings--state-of-the-art and emerging microtechnologies.

Macdara T Glynn1, David J Kinahan, Jens Ducrée.   

Abstract

Modern advancements in pharmaceuticals have provided individuals who have been infected with the human immunodeficiency virus (HIV) with the possibility of significantly extending their survival rates. When administered sufficiently soon after infection, antiretroviral therapy (ART) allows medical practitioners to control onset of the symptoms of the associated acquired immune deficiency syndrome (AIDS). Active monitoring of the immune system in both HIV patients and individuals who are regarded as "at-risk" is critical in the decision making process for when to start a patient on ART. A reliable and common method for such monitoring is to observe any decline in the number of CD4 expressing T-helper cells in the blood of a patient. However, the technology, expertise, infrastructure and costs to carry out such a diagnostic cannot be handled by medical services in resource-poor regions where HIV is endemic. Addressing this shortfall, commercialized point-of-care (POC) CD4 cell count systems are now available in such regions. A number of newer devices will also soon be on the market, some the result of recent maturing of charity-funded initiatives. Many of the current and imminent devices are enabled by microfluidic solutions, and this review will critically survey and analyze these POC technologies for CD4 counting, both on-market and near-to-market deployment. Additionally, promising technologies under development that may usher in a new generation of devices will be presented.

Entities:  

Mesh:

Year:  2013        PMID: 23670110     DOI: 10.1039/c3lc50213a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  12 in total

1.  A flow-through cell counting assay for point-of-care enumeration of CD4 T-cells.

Authors:  Simon Bystryak; Rajiv P Bandwar; Rasa Santockyte
Journal:  J Virol Methods       Date:  2019-05-28       Impact factor: 2.014

2.  Near patient CD4 count in a hospitalized HIV patient population.

Authors:  Monique Givens; Amanda Weaver; Sarah Bickman; Cathy Logan; Emilia V Noormahomed; Sam Patel; Robert T Schooley; Constance A Benson; Michael J Lochhead
Journal:  Cytometry B Clin Cytom       Date:  2015-05-27       Impact factor: 3.058

3.  Integrating Cell Phone Imaging with Magnetic Levitation (i-LEV) for Label-Free Blood Analysis at the Point-of-Living.

Authors:  Murat Baday; Semih Calamak; Naside Gozde Durmus; Ronald W Davis; Lars M Steinmetz; Utkan Demirci
Journal:  Small       Date:  2015-11-02       Impact factor: 13.281

Review 4.  Point-of-care diagnostics to improve maternal and neonatal health in low-resource settings.

Authors:  Catherine E Majors; Chelsey A Smith; Mary E Natoli; Kathryn A Kundrod; Rebecca Richards-Kortum
Journal:  Lab Chip       Date:  2017-10-11       Impact factor: 6.799

5.  Laboratory and field evaluation of the Partec CyFlow miniPOC for absolute and relative CD4 T-cell enumeration.

Authors:  Djibril Wade; Papa Alassane Diaw; Géraldine Daneau; Abdoul Aziz Diallo; Souleymane Mboup; Tandakha Ndiaye Dieye; Luc Kestens
Journal:  PLoS One       Date:  2015-02-17       Impact factor: 3.240

6.  Reliable and accurate CD4+ T cell count and percent by the portable flow cytometer CyFlow MiniPOC and "CD4 Easy Count Kit-Dry", as revealed by the comparison with the gold standard dual platform technology.

Authors:  Milena Nasi; Sara De Biasi; Elena Bianchini; Lara Gibellini; Marcello Pinti; Tiziana Scacchetti; Tommaso Trenti; Vanni Borghi; Cristina Mussini; Andrea Cossarizza
Journal:  PLoS One       Date:  2015-01-26       Impact factor: 3.240

7.  A portable optical reader and wall projector towards enumeration of bio-conjugated beads or cells.

Authors:  Macdara T Glynn; David J Kinahan; Niamh A McArdle; Jane L Kendlin; Triona M O'Connell; Jens Ducrée
Journal:  PLoS One       Date:  2017-12-21       Impact factor: 3.240

8.  Performance of FACSPresto Point-of-Care Instrument for CD4-T Cell Enumeration in Human Immunodeficiency Virus (HIV)-Infected Patients Attending Care and Treatment Clinics in Belgium and Tanzania.

Authors:  Géraldine Daneau; Said Aboud; Irena Prat; Willy Urassa; Luc Kestens
Journal:  PLoS One       Date:  2017-01-27       Impact factor: 3.240

Review 9.  CD-Based Microfluidics for Primary Care in Extreme Point-of-Care Settings.

Authors:  Suzanne Smith; Dario Mager; Alexandra Perebikovsky; Ehsan Shamloo; David Kinahan; Rohit Mishra; Saraí M Torres Delgado; Horacio Kido; Satadal Saha; Jens Ducrée; Marc Madou; Kevin Land; Jan G Korvink
Journal:  Micromachines (Basel)       Date:  2016-01-29       Impact factor: 2.891

Review 10.  Point of Care Diagnostics for HIV in Resource Limited Settings: An Overview.

Authors:  Sello Lebohang Manoto; Masixole Lugongolo; Ureshnie Govender; Patience Mthunzi-Kufa
Journal:  Medicina (Kaunas)       Date:  2018-03-13       Impact factor: 2.430

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.