| Literature DB >> 31142292 |
Lingling Niu1,2,3,4, Huamao Miao1,2,3,4, Tian Han1,2,3,4, Lan Ding1,2,3,4, Xiaoying Wang1,2,3,4, Xingtao Zhou5,6,7,8.
Abstract
BACKGROUND: High myopia with shallow anterior chamber depth (ACD less than 2.8 mm) is not rare. This observational study aims to evaluate visual outcomes after implantation of the Visian Implantable Collamer Lens with a central hole (ICL V4c) in these patients.Entities:
Keywords: Anterior chamber depth; High myopia; ICL V4c
Mesh:
Year: 2019 PMID: 31142292 PMCID: PMC6542118 DOI: 10.1186/s12886-019-1132-z
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Preoperative Patient Demographic Data in Eyes Undergoing Implantation of ICL V4c
| Characteristics | Mean ± SD ( | Range (Minimum, Maximum) |
|---|---|---|
| Age (y) | 32.45 ± 6.85 | 20, 42 |
| Follow-up (moths) | 15.35 ± 4.90 | 12, 25 |
| CDVA (Decimal) | 0.86 ± 0.31 | 0.1, 1.2 |
| Spherical refractive error (D) | −13.31 ± 4.34 | −6.50, − 25.50 |
| Cylindrical refractive error (D) | −1.50 ± 1.01 | −4.00, 0 |
| Spherical equivalent (D) | − 14.03 ± 4.46 | − 7.50, − 25.75 |
| ACD (mm) | 2.74 ± 0.04 | 2.65, 2.79 |
| WTW (mm) | 11.67 ± 0.33 | 11.0, 12.9 |
| IOP (mmHg) | 15.76 ± 2.68 | 9.7, 20.9 |
| ECD (cells/mm2) | 3235.08 ± 478.07 | 2379, 4132 |
| Axial length(mm) | 28.30 ± 2.01 | 24.18, 32.84 |
CDVA = Corrected distance visual acuity; D = Diopter; ACD = Anterior chamber depth; WTW = White-to-white; IOP = Intraocular pressure; ECD = Endothelial cell count
Data are mean ± SD unless otherwise indicated
Fig. 1Clinical outcomes of 51 myopia eyes with shallow anterior chamber depth (ACD) after implantation of ICL with a central hole (ICL V4c). Changes of corrected distance visual acuity (CDVA) (a), distribution of postoperative spherical equivalent refraction (b), cumulative percentage of the eyes attaining specified cumulative levels of uncorrected distance visual acuity (UDVA) (c), attempted spherical equivalent refraction change versus the achieved spherical equivalent refraction change (d) at the last follow-up were plotted. Stability of postoperative spherical equivalent refraction was evaluated up to 12 months after surgery (e)
Clinical Outcomes in Eyes Undergoing Implantation of ICL V4c At The Last Visit
| Characteristics | Mean ± SD (51 eyes) | Range (Minimum, Maximum) |
|---|---|---|
| UDVA (Decimal) | 0.89 ± 0.30 | 0.12, 1.2 |
| CDVA (Decimal) | 1.00 ± 0.27 | 0.4, 1.5 |
| Spherical equivalent (D) | −0.67 ± 1.29 | − 6.00, 0.75 |
| Implanted ICL size (mm) | 12.58 ± 0.31 | 12.1, 13.7 |
| IOP (mmHg) | 15.15 ± 2.57 | 9.7, 20.4 |
| ECD (cells/mm2) | 2963.64 ± 396.17 | 2358, 3651 |
| Axial length(mm) | 28.33 ± 2.15 | 24.19, 33.15 |
| Vault (mm) | 380.00 ± 152.84 | 90, 700 |
CDVA = Corrected distance visual acuity; UDVA = Uncorrected distance visual acuity; IOP = Intraocular pressure; ECD = Endothelial cell density; Data are mean ± SD unless otherwise indicated
Fig. 2Locations of the ICL V4c in the eyes with vaults less than 200 μm at the last follow-ups. Images were captured by ultrasound biomicroscopy (UBM). The haptic of ICL V4c was on the ciliary processes in three eyes (a) and were at the posterior segment of the ciliary process in the forth eye (a representative image shown in b)