Literature DB >> 31135357

Debiasing-Based Noise Suppression for Ultrafast Ultrasound Microvessel Imaging.

Chengwu Huang, Pengfei Song, Ping Gong, Joshua D Trzasko, Armando Manduca, Shigao Chen.   

Abstract

Ultrasound microvessel imaging (UMI) based on the combination of singular value decomposition (SVD) clutter filtering and ultrafast plane wave imaging has recently demonstrated significantly improved Doppler sensitivity, especially to small vessels that are invisible to conventional Doppler imaging. Practical implementation of UMI is hindered by the high computational cost associated with SVD and low blood signal-to-noise ratio (SNR) in deep regions of the tissue due to the lack of transmit focusing of plane waves. Concerning the high computational cost, an accelerated SVD clutter filtering method based on randomized SVD (rSVD) and randomized spatial downsampling (rSD) was recently proposed by our group, which showed the feasibility of real-time implementation of UMI. Concerning the low blood flow SNR in deep imaging regions, here we propose a noise suppression method based on noise debiasing that can be easily applied to the accelerated SVD method to bridge the gap between real-time implementation and high imaging quality. The proposed method experimentally measures the noise-induced bias by collecting the noise signal using the identical imaging sequence as regular UMI, but with the ultrasound transmission turned off. The estimated bias can then be subtracted from the original power Doppler (PD) image to obtain effective noise suppression. The feasibility of the proposed method was validated under different ultrasound imaging parameters [including transmitting voltages and time-gain compensation (TGC) settings] with a phantom experiment. The noise-debiased images showed an increase of up to 15.3 and 13.4 dB in SNR as compared to original PD images on the blood flow phantom and an in vivo human kidney data set, respectively. The proposed noise suppression method has negligible computational cost and can be conveniently combined with the previously proposed accelerated SVD clutter filtering technique to achieve high quality, real-time UMI imaging.

Entities:  

Year:  2019        PMID: 31135357      PMCID: PMC6743739          DOI: 10.1109/TUFFC.2019.2918180

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  19 in total

Review 1.  Eigen-based clutter filter design for ultrasound color flow imaging: a review.

Authors:  Alfred Yu; Lasse Lovstakken
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-05       Impact factor: 2.725

2.  Ultrafast compound Doppler imaging: providing full blood flow characterization.

Authors:  Jeremy Bercoff; Gabriel Montaldo; Thanasis Loupas; David Savery; Fabien Mézière; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-01       Impact factor: 2.725

3.  Functional ultrasound imaging of the brain.

Authors:  Emilie Macé; Gabriel Montaldo; Ivan Cohen; Michel Baulac; Mathias Fink; Mickael Tanter
Journal:  Nat Methods       Date:  2011-07-03       Impact factor: 28.547

4.  Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity.

Authors:  Charlie Demené; Thomas Deffieux; Mathieu Pernot; Bruno-Félix Osmanski; Valérie Biran; Jean-Luc Gennisson; Lim-Anna Sieu; Antoine Bergel; Stéphanie Franqui; Jean-Michel Correas; Ivan Cohen; Olivier Baud; Mickael Tanter
Journal:  IEEE Trans Med Imaging       Date:  2015-04-30       Impact factor: 10.048

5.  Real-time imaging of brain activity in freely moving rats using functional ultrasound.

Authors:  Alan Urban; Clara Dussaux; Guillaume Martel; Clément Brunner; Emilie Mace; Gabriel Montaldo
Journal:  Nat Methods       Date:  2015-07-20       Impact factor: 28.547

6.  Coherent flow power Doppler (CFPD): flow detection using spatial coherence beamforming.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-06       Impact factor: 2.725

Review 7.  Ultrafast imaging in biomedical ultrasound.

Authors:  Mickael Tanter; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-01       Impact factor: 2.725

8.  Functional ultrasound imaging of the brain: theory and basic principles.

Authors:  Emilie Mace; Gabriel Montaldo; Bruno-Felix Osmanski; Ivan Cohen; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-03       Impact factor: 2.725

9.  3-D ultrafast Doppler imaging applied to the noninvasive mapping of blood vessels in vivo.

Authors:  Jean Provost; Clement Papadacci; Charlie Demene; Jean-Luc Gennisson; Mickael Tanter; Mathieu Pernot
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-08       Impact factor: 2.725

10.  Functional ultrasound imaging of intrinsic connectivity in the living rat brain with high spatiotemporal resolution.

Authors:  Bruno-Félix Osmanski; Sophie Pezet; Ana Ricobaraza; Zsolt Lenkei; Mickael Tanter
Journal:  Nat Commun       Date:  2014-10-03       Impact factor: 14.919

View more
  16 in total

1.  Experimental Validation of Perfusion Imaging With HOSVD Clutter Filters.

Authors:  Yang Zhu; MinWoo Kim; Cameron Hoerig; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-21       Impact factor: 2.725

2.  Real time SVD-based clutter filtering using randomized singular value decomposition and spatial downsampling for micro-vessel imaging on a Verasonics ultrasound system.

Authors:  U-Wai Lok; Pengfei Song; Joshua D Trzasko; Ron Daigle; Eric A Borisch; Chengwu Huang; Ping Gong; Shanshan Tang; Wenwu Ling; Shigao Chen
Journal:  Ultrasonics       Date:  2020-04-25       Impact factor: 2.890

3.  Ultrasound Attenuation Estimation in Harmonic Imaging for Robust Fatty Liver Detection.

Authors:  Ping Gong; Chenyun Zhou; Pengfei Song; Chengwu Huang; U-Wai Lok; Shanshan Tang; Kymberly Watt; Matthew Callstrom; Shigao Chen
Journal:  Ultrasound Med Biol       Date:  2020-08-06       Impact factor: 2.998

4.  A Spatial Coherence Beamformer Design for Power Doppler Imaging.

Authors:  Kathryn Ozgun; Jaime Tierney; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2019-11-14       Impact factor: 10.048

Review 5.  Novel Uses of Ultrasound to Assess Kidney Mechanical Properties.

Authors:  Matthew W Urban; Andrew D Rule; Thomas D Atwell; Shigao Chen
Journal:  Kidney360       Date:  2021-07-01

Review 6.  Use of Ultrasound to Assess Hemodynamics in Acutely Ill Patients.

Authors:  Sami Safadi; Sarah Murthi; Kianoush B Kashani
Journal:  Kidney360       Date:  2021-06-02

7.  Adaptive and Robust Vessel Quantification in Contrast-Free Ultrafast Ultrasound Microvessel Imaging.

Authors:  Shanshan Tang; Chengwu Huang; Ping Gong; U-Wai Lok; Chenyun Zhou; Lulu Yang; Kate M Knoll; Kathryn A Robinson; Shannon P Sheedy; Joel G Fletcher; David H Bruining; John M Knudsen; Shigao Chen
Journal:  Ultrasound Med Biol       Date:  2022-07-23       Impact factor: 3.694

8.  Quantitative Inflammation Assessment for Crohn Disease Using Ultrasensitive Ultrasound Microvessel Imaging: A Pilot Study.

Authors:  Ping Gong; Pengfei Song; Amy B Kolbe; Shannon P Sheedy; Chengwu Huang; Wenwu Ling; Yue Yu; Chenyun Zhou; U Wai Lok; Shanshan Tang; David H Bruining; John M Knudsen; Shigao Chen
Journal:  J Ultrasound Med       Date:  2020-04-16       Impact factor: 2.153

9.  Super-resolution ultrasound localization microscopy based on a high frame-rate clinical ultrasound scanner: an in-human feasibility study.

Authors:  Chengwu Huang; Wei Zhang; Ping Gong; U-Wai Lok; Shanshan Tang; Tinghui Yin; Xirui Zhang; Lei Zhu; Maodong Sang; Pengfei Song; Rongqin Zheng; Shigao Chen
Journal:  Phys Med Biol       Date:  2021-04-08       Impact factor: 3.609

10.  Improved Ultrasound Microvessel Imaging Using Deconvolution with Total Variation Regularization.

Authors:  U-Wai Lok; Joshua D Trzasko; Chengwu Huang; Shanshan Tang; Ping Gong; Yohan Kim; Fabrice Lucien; Matthew R Lowerison; Pengfei Song; Shigao Chen
Journal:  Ultrasound Med Biol       Date:  2021-01-16       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.