Literature DB >> 31725374

A Spatial Coherence Beamformer Design for Power Doppler Imaging.

Kathryn Ozgun, Jaime Tierney, Brett Byram.   

Abstract

Acoustic clutter is a primary source of image degradation in ultrasound imaging. In the context of flow imaging, tissue and acoustic clutter signals are often much larger in magnitude than the blood signal, which limits the sensitivity of conventional power Doppler in SNR-limited environments. This has motivated the development of coherence-based beamformers, including Coherent Flow Power Doppler (CFPD), which have demonstrated efficacy in mitigating sources of diffuse clutter. However, CFPD uses a measure of normalized coherence, which incurs a non-linear relationship between image intensity and the magnitude of the blood echo. As a result, CFPD is not a robust approach to study gradation of blood signal energy, which depicts the fractional moving blood volume. We propose the application of mutual intensity, rather than normalized coherence, to retain the clutter suppression capability inherent in coherence beamforming, while preserving the underlying signal energy. Feasibility of this approach was shown via Field II simulations, phantoms, and in vivo human liver data. In addition, we derive an adaptive statistical threshold for the suppression of residual noise signals. Overall, this beamformer design shows promise as an alternative technique to depict flow volume gradation in cluttered imaging environments.

Entities:  

Mesh:

Year:  2019        PMID: 31725374      PMCID: PMC7265983          DOI: 10.1109/TMI.2019.2953657

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  34 in total

1.  Debiasing-Based Noise Suppression for Ultrafast Ultrasound Microvessel Imaging.

Authors:  Chengwu Huang; Pengfei Song; Ping Gong; Joshua D Trzasko; Armando Manduca; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-05-22       Impact factor: 2.725

Review 2.  Settings and artefacts relevant in colour/power Doppler ultrasound in rheumatology.

Authors:  S T Torp-Pedersen; L Terslev
Journal:  Ann Rheum Dis       Date:  2007-11-29       Impact factor: 19.103

3.  The random phase transducer: a new technique for incoherent processing-basic principles and theory.

Authors:  M Fink; R Mallart; F Cancre
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1990       Impact factor: 2.725

4.  Measurement of blood perfusion in tissue using Doppler ultrasound.

Authors:  S O Dymling; H W Persson; C H Hertz
Journal:  Ultrasound Med Biol       Date:  1991       Impact factor: 2.998

5.  Ultrafast compound Doppler imaging: providing full blood flow characterization.

Authors:  Jeremy Bercoff; Gabriel Montaldo; Thanasis Loupas; David Savery; Fabien Mézière; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-01       Impact factor: 2.725

6.  Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity.

Authors:  Charlie Demené; Thomas Deffieux; Mathieu Pernot; Bruno-Félix Osmanski; Valérie Biran; Jean-Luc Gennisson; Lim-Anna Sieu; Antoine Bergel; Stéphanie Franqui; Jean-Michel Correas; Ivan Cohen; Olivier Baud; Mickael Tanter
Journal:  IEEE Trans Med Imaging       Date:  2015-04-30       Impact factor: 10.048

7.  Equivalence of time and aperture domain additive noise in ultrasound coherence.

Authors:  Nick B Bottenus; Gregg E Trahey
Journal:  J Acoust Soc Am       Date:  2015-01       Impact factor: 1.840

8.  Combining Slow Flow Techniques With Adaptive Demodulation for Improved Perfusion Ultrasound Imaging Without Contrast.

Authors:  Jaime Tierney; Kristy Walsh; Helen Griffith; Jennifer Baker; Daniel B Brown; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-02-07       Impact factor: 2.725

9.  Lower-limb vascular imaging with acoustic radiation force elastography: demonstration of in vivo feasibility.

Authors:  Douglas Dumont; Jeremy Dahl; Elizabeth Miller; Jason Allen; Brian Fahey; Gregg Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-05       Impact factor: 2.725

10.  Advanced hepatocellular carcinoma: CT perfusion of liver and tumor tissue--initial experience.

Authors:  Dushyant V Sahani; Nagaraj-Setty Holalkere; Peter R Mueller; Andrew X Zhu
Journal:  Radiology       Date:  2007-06       Impact factor: 11.105

View more
  5 in total

1.  Adaptive and Robust Vessel Quantification in Contrast-Free Ultrafast Ultrasound Microvessel Imaging.

Authors:  Shanshan Tang; Chengwu Huang; Ping Gong; U-Wai Lok; Chenyun Zhou; Lulu Yang; Kate M Knoll; Kathryn A Robinson; Shannon P Sheedy; Joel G Fletcher; David H Bruining; John M Knudsen; Shigao Chen
Journal:  Ultrasound Med Biol       Date:  2022-07-23       Impact factor: 3.694

Review 2.  Spatial Coherence in Medical Ultrasound: A Review.

Authors:  James Long; Gregg Trahey; Nick Bottenus
Journal:  Ultrasound Med Biol       Date:  2022-03-11       Impact factor: 3.694

3.  Spatiotemporal Coherence to Quantify Sources of Image Degradation in Ultrasonic Imaging.

Authors:  Emelina P Vienneau; Kathryn A Ozgun; Brett C Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

4.  Multidimensional Clutter Filtering of Aperture Domain Data for Improved Blood Flow Sensitivity.

Authors:  Kathryn A Ozgun; Brett C Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-07-26       Impact factor: 3.267

5.  Simultaneous Noise Suppression and Incoherent Artifact Reduction in Ultrafast Ultrasound Vascular Imaging.

Authors:  Chengwu Huang; Pengfei Song; Joshua D Trzasko; Ping Gong; U-Wai Lok; Shanshan Tang; Armando Manduca; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-05-25       Impact factor: 3.267

  5 in total