Literature DB >> 32324548

Experimental Validation of Perfusion Imaging With HOSVD Clutter Filters.

Yang Zhu, MinWoo Kim, Cameron Hoerig, Michael F Insana.   

Abstract

Novel pulsed-Doppler methods for perfusion imaging are validated using dialysis cartridges as perfusion phantoms. Techniques that were demonstrated qualitatively at 24 MHz, in vivo, are here examined quantitatively at 5 and 12.5 MHz using phantoms with the blood-mimicking fluid flow within cellulose microfibers. One goal is to explore a variety of flow states to optimize measurement sensitivity and flow accuracy. The results show that 2-3-s echo acquisitions at roughly 10 frames/s yield the highest sensitivity to flows of 1-4 mL/min. A second goal is to examine methods for setting the parameters of higher order singular value decomposition (HOSVD) clutter filters. For stationary or moving clutter, the velocity of the blood-mimicking fluid in the microfibers is consistently estimated within measurement uncertainty (mean coefficient of variation = 0.26). Power Doppler signals were equivalent for stationary and moving clutter after clutter filtering, increasing approximately 3 dB/mL/min of blood-mimicking fluid flow for 0 ≤ q ≤ 4 mL/min. Comparisons between phantom and preclinical images show that peripheral perfusion imaging can be reliably achieved without contrast enhancement.

Entities:  

Mesh:

Year:  2020        PMID: 32324548      PMCID: PMC7501588          DOI: 10.1109/TUFFC.2020.2989109

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  21 in total

1.  Performance of ultrasound echo decomposition using singular spectrum analysis.

Authors:  W C de Albuquerque Pereira; C D Maciel
Journal:  Ultrasound Med Biol       Date:  2001-09       Impact factor: 2.998

2.  Adaptive clutter filtering via blind source separation for two-dimensional ultrasonic blood velocity measurement.

Authors:  Caterina M Gallippi; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2002-10       Impact factor: 1.578

3.  Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity.

Authors:  Charlie Demené; Thomas Deffieux; Mathieu Pernot; Bruno-Félix Osmanski; Valérie Biran; Jean-Luc Gennisson; Lim-Anna Sieu; Antoine Bergel; Stéphanie Franqui; Jean-Michel Correas; Ivan Cohen; Olivier Baud; Mickael Tanter
Journal:  IEEE Trans Med Imaging       Date:  2015-04-30       Impact factor: 10.048

4.  Expanding Acquisition and Clutter Filter Dimensions for Improved Perfusion Sensitivity.

Authors:  MinWoo Kim; Craig K Abbey; Jamila Hedhli; Lawrence W Dobrucki; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-06-26       Impact factor: 2.725

Review 5.  Microvascular imaging: techniques and opportunities for clinical physiological measurements.

Authors:  John Allen; Kevin Howell
Journal:  Physiol Meas       Date:  2014-06-09       Impact factor: 2.833

6.  Visualization of Small-Diameter Vessels by Reduction of Incoherent Reverberation With Coherent Flow Power Doppler.

Authors:  You Leo Li; Dongwoon Hyun; Lotfi Abou-Elkacem; Juergen Karl Willmann; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11       Impact factor: 2.725

7.  The singular value filter: a general filter design strategy for PCA-based signal separation in medical ultrasound imaging.

Authors:  F William Mauldin; Dan Lin; John A Hossack
Journal:  IEEE Trans Med Imaging       Date:  2011-06-20       Impact factor: 10.048

Review 8.  Comparison of global estimates of prevalence and risk factors for peripheral artery disease in 2000 and 2010: a systematic review and analysis.

Authors:  F Gerald R Fowkes; Diana Rudan; Igor Rudan; Victor Aboyans; Julie O Denenberg; Mary M McDermott; Paul E Norman; Uchechukwe K A Sampson; Linda J Williams; George A Mensah; Michael H Criqui
Journal:  Lancet       Date:  2013-08-01       Impact factor: 79.321

9.  Perfusion Assessment in Critical Limb Ischemia: Principles for Understanding and the Development of Evidence and Evaluation of Devices: A Scientific Statement From the American Heart Association.

Authors:  Sanjay Misra; Mehdi H Shishehbor; Edwin A Takahashi; Herbert D Aronow; Luke P Brewster; Matthew C Bunte; Esther S H Kim; Jonathan R Lindner; Kathleen Rich
Journal:  Circulation       Date:  2019-08-12       Impact factor: 29.690

Review 10.  2016 AHA/ACC Guideline on the Management of Patients With Lower Extremity Peripheral Artery Disease: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines.

Authors:  Marie D Gerhard-Herman; Heather L Gornik; Coletta Barrett; Neal R Barshes; Matthew A Corriere; Douglas E Drachman; Lee A Fleisher; Francis Gerry R Fowkes; Naomi M Hamburg; Scott Kinlay; Robert Lookstein; Sanjay Misra; Leila Mureebe; Jeffrey W Olin; Rajan A G Patel; Judith G Regensteiner; Andres Schanzer; Mehdi H Shishehbor; Kerry J Stewart; Diane Treat-Jacobson; M Eileen Walsh
Journal:  Circulation       Date:  2016-11-13       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.