Literature DB >> 31111961

Objective assessment of the effects of tumor motion in radiation therapy.

Yijun Ding1, Harrison H Barrett1,2, Matthew A Kupinski1, Yevgeniy Vinogradskiy3, Moyed Miften3, Bernard L Jones3.   

Abstract

PURPOSE: Internal organ motion reduces the accuracy and efficacy of radiation therapy. However, there is a lack of tools to objectively (based on a medical or scientific task) assess the dosimetric consequences of motion, especially on an individual basis. We propose to use therapy operating characteristic (TOC) analysis to quantify the effects of motion on treatment efficacy for individual patients. We demonstrate the application of this tool with pancreatic stereotactic body radiation therapy (SBRT) clinical data and explore the origin of motion sensitivity.
METHODS: The technique is described as follows. (a) Use tumor-motion data measured from patients to calculate the motion-convolved dose of the gross tumor volume (GTV) and the organs at risk (OARs). (b) Calculate tumor control probability (TCP) and normal tissue complication probability (NTCP) from the motion-convolved dose-volume histograms. (c) Construct TOC curves from TCP and NTCP models. (d) Calculate the area under the TOC curve (AUTOC) and use it as a figure of merit for treatment efficacy. We used tumor motion data measured from patients to calculate the relation between AUTOC and motion magnitude for 25 pancreatic SBRT treatment plans. Furthermore, to explore the driving factor of motion sensitivity of a given plan, we compared the dose distribution of motion-sensitive plans and motion-robust plans and studied the dependence of motion sensitivity to motion directions.
RESULTS: Our technique is able to recognize treatment plans that are sensitive to motion. Under the presence of motion, the treatment efficacy of some plans changes from providing high tumor control and low risks of complications to providing no tumor control and high risks of side effects. Several treatment plans experience falloffs in AUTOC at a smaller magnitude of motion than other plans. In our dataset, a potential indicator of a motion-sensitive treatment plan is that the duodenum is in proximity to the tumor in the SI direction.
CONCLUSIONS: The TOC framework can serve as a tool to quantify the effects of internal organ motion in radiation therapy. With pancreatic SBRT clinical data, we applied this tool to study the change in treatment efficacy induced by motion for individual treatment plans. This framework could potentially be used clinically to understand the effects of motion in an individual patient and to design a patient-specific motion management plan. This framework could also be used in research to evaluate different components of the treatment process, such as motion-management techniques, treatment-planning algorithms, and treatment margins.
© 2019 American Association of Physicists in Medicine.

Entities:  

Keywords:  NTCP; TCP; TOC; treatment efficacy; tumor motion

Mesh:

Year:  2019        PMID: 31111961      PMCID: PMC6625917          DOI: 10.1002/mp.13601

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  60 in total

1.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy.

Authors:  M van Herk; P Remeijer; C Rasch; J V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-07-01       Impact factor: 7.038

2.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability.

Authors:  J C Stroom; H C de Boer; H Huizenga; A G Visser
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-03-01       Impact factor: 7.038

3.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation.

Authors:  Thomas Bortfeld; Kimmo Jokivarsi; Michael Goitein; Jong Kung; Steve B Jiang
Journal:  Phys Med Biol       Date:  2002-07-07       Impact factor: 3.609

4.  An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments.

Authors:  Steve B Jiang; Cynthia Pope; Khaled M Al Jarrah; Jong H Kung; Thomas Bortfeld; George T Y Chen
Journal:  Phys Med Biol       Date:  2003-06-21       Impact factor: 3.609

5.  BIOPLAN: software for the biological evaluation of. Radiotherapy treatment plans.

Authors:  B Sanchez-Nieto; A E Nahum
Journal:  Med Dosim       Date:  2000       Impact factor: 1.482

6.  Optimization of the dose level for a given treatment plan to maximize the complication-free tumor cure.

Authors:  B K Lind; P Mavroidis; S Hyödynmaa; C Kappas
Journal:  Acta Oncol       Date:  1999       Impact factor: 4.089

7.  Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions.

Authors:  Kei Kitamura; Hiroki Shirato; Yvette Seppenwoolde; Rikiya Onimaru; Makoto Oda; Katsuhisa Fujita; Shinichi Shimizu; Nobuo Shinohara; Toru Harabayashi; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-08-01       Impact factor: 7.038

8.  Quantifying the effect of intrafraction motion during breast IMRT planning and dose delivery.

Authors:  R George; P J Keall; V R Kini; S S Vedam; J V Siebers; Q Wu; M H Lauterbach; D W Arthur; R Mohan
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

9.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

10.  Interfractional and intrafractional accuracy during radiotherapy of gynecologic carcinomas: a comprehensive evaluation using the ExacTrac system.

Authors:  Elisabeth Weiss; Hilke Vorwerk; Susanne Richter; Clemens F Hess
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

View more
  1 in total

1.  Study on Motion Management of Pancreatic Cancer Treated by CyberKnife.

Authors:  Shenghua Jing; Changchen Jiang; Xiaoqin Ji; Xiangnan Qiu; Jing Li; Xiangdong Sun; Xixu Zhu
Journal:  Front Oncol       Date:  2021-12-02       Impact factor: 6.244

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.