Literature DB >> 12164582

Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation.

Thomas Bortfeld1, Kimmo Jokivarsi, Michael Goitein, Jong Kung, Steve B Jiang.   

Abstract

There has been some concern that organ motion, especially intra-fraction organ motion due to breathing, can negate the potential merit of intensity-modulated radiotherapy (IMRT). We wanted to find out whether this concern is justified. Specifically, we wanted to investigate whether IMRT delivery techniques with moving parts, e.g., with a multileaf collimator (MLC), are particularly sensitive to organ motion due to the interplay between organ motion and leaf motion. We also wanted to know if, and by how much, fractionation of the treatment can reduce the effects. We performed a statistical analysis and calculated the expected dose values and dose variances for volume elements of organs that move during the delivery of the IMRT. We looked at the overall influence of organ motion during the course of a fractionated treatment. A linear-quadratic model was used to consider fractionation effects. Furthermore, we developed software to simulate motion effects for IMRT delivery with an MLC, with compensators, and with a scanning beam. For the simulation we assumed a sinusoidal motion in an isocentric plane. We found that the expected dose value is independent of the treatment technique. It is just a weighted average over the path of motion of the dose distribution without motion. If the treatment is delivered in several fractions, the distribution of the dose around the expected value is close to a Gaussian. For a typical treatment with 30 fractions, the standard deviation is generally within 1% of the expected value for MLC delivery if one assumes a typical motion amplitude of 5 mm (1 cm peak to peak). The standard deviation is generally even smaller for the compensator but bigger for scanning beam delivery. For the latter it can be reduced through multiple deliveries ('paintings') of the same field. In conclusion, the main effect of organ motion in IMRT is an averaging of the dose distribution without motion over the path of the motion. This is the same as for treatments with conventional beams. Additional effects that are specific to the IMRT delivery technique appear to be relatively small, except for the scanning beam.

Mesh:

Year:  2002        PMID: 12164582     DOI: 10.1088/0031-9155/47/13/302

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  121 in total

1.  A phantom model demonstration of tomotherapy dose painting delivery, including managed respiratory motion without motion management.

Authors:  Michael W Kissick; Xiaohu Mo; Keisha C McCall; Leah K Schubert; David C Westerly; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2010-04-30       Impact factor: 3.609

2.  Interplay effect modeling in stereotactic body radiotherapy treatment of liver cancer using volumetric modulated arc therapy.

Authors:  Deepak Thaper; Arun S Oinam; Rose Kamal; Gaganpreet Singh; Bhumika Handa; Vivek Kumar; Hanuman P Yadav
Journal:  Phys Eng Sci Med       Date:  2021-02-04

Review 3.  Intensity-Modulated Radiotherapy versus 3-Dimensional Conformal Radiotherapy Strategies for Locally Advanced Non-Small-Cell Lung Cancer.

Authors:  Uğur Selek; Yasemin Bölükbaşı; James W Welsh; Erkan Topkan
Journal:  Balkan Med J       Date:  2014-09-13       Impact factor: 2.021

4.  Development of a novel post-processing treatment planning platform for 4D radiotherapy.

Authors:  Lan Lin; Chengyu Shi; Yaxi Liu; Gregory Swanson; Nikos Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2008-04

5.  Four-dimensional Monte Carlo simulations demonstrating how the extent of intensity-modulation impacts motion effects in proton therapy lung treatments.

Authors:  Stephen Dowdell; Clemens Grassberger; Harald Paganetti
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

6.  Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer.

Authors:  Chenbin Liu; Steven E Schild; Joe Y Chang; Zhongxing Liao; Shawn Korte; Jiajian Shen; Xiaoning Ding; Yanle Hu; Yixiu Kang; Sameer R Keole; Terence T Sio; William W Wong; Narayan Sahoo; Martin Bues; Wei Liu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-02-14       Impact factor: 7.038

7.  New approach in lung cancer radiotherapy offers better normal tissue sparing.

Authors:  Ivaylo B Mihaylov
Journal:  Radiother Oncol       Date:  2016-09-28       Impact factor: 6.280

8.  Tumor trailing strategy for intensity-modulated radiation therapy of moving targets.

Authors:  Alexei Trofimov; Christian Vrancic; Timothy C Y Chan; Gregory C Sharp; Thomas Bortfeld
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

9.  Quantifying the interplay effect in prostate IMRT delivery using a convolution-based method.

Authors:  Haisen S Li; Indrin J Chetty; Timothy D Solberg
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

10.  Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients.

Authors:  Tokihiro Yamamoto; Ulrich Langner; Billy W Loo; John Shen; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-25       Impact factor: 7.038

View more