Literature DB >> 12870582

An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments.

Steve B Jiang1, Cynthia Pope, Khaled M Al Jarrah, Jong H Kung, Thomas Bortfeld, George T Y Chen.   

Abstract

Respiration-induced tumour motion can potentially compromise the use of intensity-modulated radiotherapy (IMRT) as a dose escalation tool for lung tumour treatment. We have experimentally investigated the intra-fractional organ motion effects in lung IMRT treatments delivered by multi-leaf collimator (MLC). An in-house made motor-driven platform, which moves sinusoidally with an amplitude of 1 cm and a period of 4 s, was used to mimic tumour motion. Tumour motion was simulated along cranial-caudal direction while MLC leaves moved across the patient from left to right, as in most clinical cases. The dose to a point near the centre of the tumour mass was measured according to geometric and dosimetric parameters from two five-field lung IMRT plans. For each field, measurement was done for two dose rates (300 and 500 MU min(-1)), three MLC delivery modes (sliding window, step-and-shoot with 10 and 20 intensity levels) and eight equally spaced starting phases of tumour motion. The dose to the measurement point delivered from all five fields was derived for both a single fraction and 30 fractions by randomly sampling from measured dose values of each field at different initial phases. It was found that the mean dose to a moving tumour differs slightly (<2-3%) from that to a static tumour. The variation in breathing phase at the start of dose delivery results in a maximum variation around the mean dose of greater than 30% for one field. The full width at half maximum for the probability distribution of the point dose is up to 8% for all five fields in a single fraction, but less than 1-2% after 30 fractions. In general, lower dose rate can reduce the motion-caused dose variation and therefore might be preferable for lung IMRT when no motion mitigation techniques are used. From the two IMRT cases we studied where tumour motion is perpendicular to MLC leaf motion, the dose variation was found to be insensitive to the MLC delivery mode.

Entities:  

Mesh:

Year:  2003        PMID: 12870582     DOI: 10.1088/0031-9155/48/12/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  74 in total

1.  Robust optimization of intensity modulated proton therapy.

Authors:  Wei Liu; Xiaodong Zhang; Yupeng Li; Radhe Mohan
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Interplay effect modeling in stereotactic body radiotherapy treatment of liver cancer using volumetric modulated arc therapy.

Authors:  Deepak Thaper; Arun S Oinam; Rose Kamal; Gaganpreet Singh; Bhumika Handa; Vivek Kumar; Hanuman P Yadav
Journal:  Phys Eng Sci Med       Date:  2021-02-04

3.  Development of a novel post-processing treatment planning platform for 4D radiotherapy.

Authors:  Lan Lin; Chengyu Shi; Yaxi Liu; Gregory Swanson; Nikos Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2008-04

4.  Robust treatment planning with conditional value at risk chance constraints in intensity-modulated proton therapy.

Authors:  Yu An; Jianming Liang; Steven E Schild; Martin Bues; Wei Liu
Journal:  Med Phys       Date:  2017-01-03       Impact factor: 4.071

Review 5.  A review of intensity-modulated radiation therapy.

Authors:  Laurie E Gaspar; Meisong Ding
Journal:  Curr Oncol Rep       Date:  2008-07       Impact factor: 5.075

Review 6.  Robustness Analysis for External Beam Radiation Therapy Treatment Plans: Describing Uncertainty Scenarios and Reporting Their Dosimetric Consequences.

Authors:  Adam D Yock; Radhe Mohan; Stella Flampouri; Walter Bosch; Paige A Taylor; David Gladstone; Siyong Kim; Jason Sohn; Robert Wallace; Ying Xiao; Jeff Buchsbaum
Journal:  Pract Radiat Oncol       Date:  2018-12-15

7.  Patient-specific quantification of respiratory motion-induced dose uncertainty for step-and-shoot IMRT of lung cancer.

Authors:  Heng Li; Peter Park; Wei Liu; Jason Matney; Zhongxing Liao; Peter Balter; Yupeng Li; Xiaodong Zhang; Xiaoqiang Li; X Ronald Zhu
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

8.  Quantifying the interplay effect in prostate IMRT delivery using a convolution-based method.

Authors:  Haisen S Li; Indrin J Chetty; Timothy D Solberg
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

9.  Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients.

Authors:  Tokihiro Yamamoto; Ulrich Langner; Billy W Loo; John Shen; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-25       Impact factor: 7.038

10.  Evaluation of tumor motion effects on dose distribution for hypofractionated intensity-modulated radiotherapy of non-small-cell lung cancer.

Authors:  Hyejoo Kang; Ellen D Yorke; Jie Yang; Chen-Shou Chui; Kenneth E Rosenzweig; Howard I Amols
Journal:  J Appl Clin Med Phys       Date:  2010-06-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.