Literature DB >> 31067926

Investigation of the repeatability and reproducibility of hydrophone measurements of medical ultrasound fields.

Eleanor Martin1, Bradley Treeby1.   

Abstract

Accurate measurements of acoustic pressure are required for characterisation of ultrasonic transducers and for experimental validation of models of ultrasound propagation. Errors in measured pressure can arise from a variety of sources, including variations in the properties of the source and measurement equipment, calibration uncertainty, and processing of measured data. In this study, the repeatability of measurements made with four probe and membrane hydrophones was examined. The pressures measured by these hydrophones in three different ultrasound fields, with both linear and nonlinear, pulsed and steady state driving conditions, were compared to assess the reproducibility of measurements. The coefficient of variation of the focal peak positive pressure was less than 2% for all hydrophones across five repeated measurements. When comparing hydrophones, pressures measured in a spherically focused 1.1 MHz field were within 7% for all except 1 case, and within 10% for a broadband 5 MHz pulse from a diagnostic linear array. Larger differences of up to 55% were observed between measurements of a tightly focused 3.3 MHz field, which were reduced for some hydrophones by the application of spatial averaging corrections. Overall, the major source of these differences was spatial averaging and uncertainty in the complex frequency response of the hydrophones.

Mesh:

Year:  2019        PMID: 31067926     DOI: 10.1121/1.5093306

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  12 in total

1.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Membrane Hydrophones: Theory Versus Experiment.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-24       Impact factor: 2.725

2.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

3.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part II: Validation for ARFI and Pulsed Doppler Waveforms.

Authors:  Keith A Wear; Anant Shah; Aoife M Ivory; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

4.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part I: Theory and Impact on Diagnostic Safety Indexes.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

5.  Correction for Spatial Averaging Artifacts in Hydrophone Measurements of High-Intensity Therapeutic Ultrasound: An Inverse Filter Approach.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-24       Impact factor: 2.725

6.  Hydrophone Spatial Averaging Artifacts for ARFI Beams from Array Transducers.

Authors:  Keith Wear; Anant Shah; Aoife M Ivory; Christian Baker
Journal:  IEEE Int Ultrason Symp       Date:  2020

7.  Correction for Spatial Averaging Artifacts for Circularly-Symmetric Pressure Beams Measured with Membrane Hydrophones.

Authors:  Keith Wear; Anant Shah; Christian Baker
Journal:  IEEE Int Ultrason Symp       Date:  2020

8.  Spatiotemporal Deconvolution of Hydrophone Response for Linear and Nonlinear Beams-Part I: Theory, Spatial-Averaging Correction Formulas, and Criteria for Sensitive Element Size.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

9.  Spatiotemporal Deconvolution of Hydrophone Response for Linear and Nonlinear Beams-Part II: Experimental Validation.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

10.  Synchronous temperature variation monitoring during ultrasound imaging and/or treatment pulse application: a phantom study.

Authors:  Hermes A S Kamimura; Niloufar Saharkhiz; Stephen A Lee; Elisa E Konofagou
Journal:  IEEE Open J Ultrason Ferroelectr Freq Control       Date:  2021-06-03
View more