| Literature DB >> 31067688 |
Shohei Yano1, Mohammad Javad Koohsari2,3, Ai Shibata4, Kaori Ishii5, Levi Frehlich6, Gavin R McCormack7, Koichiro Oka8.
Abstract
Background. Comparability of accelerometers in epidemiological studies is important for public health researchers. This study aimed to compare physical activity (light, LPA; moderate, MPA; and moderate-to-vigorous, MVPA) and sedentary behavior (SB) data collected using two Omron triaxial accelerometer generations (Active style Pro, ASP) among a sample of Japanese workers in a free-living environment. Methods. Thirty active and sedentary workers (24-62 years) wore two types of ASP accelerometers, the HJA-350IT (350IT) and the HJA-750C (750C), simultaneously for seven consecutive days to represent a typical week. The accelerometers estimated daily average step counts and time spent per day in LPA, MPA, and MVPA. If a participant had data for ≥4 days (>10 h/day) it was considered valid. The difference and agreement between the two ASPs were analyzed using a paired t-test, intra-class correlation coefficients (ICC), and a Bland-Altman analysis in total and for each type of worker. Results. Among all workers, the 750C measured significantly (p < 0.05) less SB, MPA, MVPA, and more LPA compared with the 350IT. The agreements in ICC were high (ICC ≥ 0.94). Conclusions. Compared with the 350IT, the newer generation 750C ASP accelerometer may not provide equivalent estimates of activity time, regardless of the type of physical activity.Entities:
Keywords: accelerometry; monitoring; motion sensors; objective assessment
Mesh:
Year: 2019 PMID: 31067688 PMCID: PMC6539210 DOI: 10.3390/ijerph16091597
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Participants’ characteristics.
| Variable | Total | Active Workers | Sedentary Workers |
|---|---|---|---|
| 26 (16) | 14 (8) | 12 (8) | |
| Height, cm | 166.4 ± 8.0 | 166.9 ± 8.4 | 165.8 ± 7.7 |
| Weight, kg | 61.4 ± 11.9 | 62.9 ± 12.8 | 59.7 ± 11.0 |
| Age, year | 42.7 ± 8.8 | 40.1 ± 8.5 | 45.8 ± 8.6 |
| BMI, kg/m² | 22.1 ± 3.4 | 22.5 ± 3.8 | 21.6 ± 2.8 |
Note: Values are expressed as a mean ± standard deviation; There were no significant differences between active and sedentary workers; BMI = body mass index.
Mean of accelerometer outcomes between 750C and 350IT devices.
| Accelerometer Outcomes | 350IT | 750C | Difference (95% CI) |
| ICC (95% CI) |
|---|---|---|---|---|---|
| Total | |||||
| Wearing time (min/day) | 834.0 ± 93.4 | 834.2 ± 92.0 | −0.2 (−3.1, 2.6) | 0.88 | 0.997 (0.990, 0.999) ** |
| SB (min/day) | 457.0 ± 121.0 | 450.5 ± 122.6 | 6.5 (1.4, 11.5) | <0.05 | 0.994 (0.981, 0.998) ** |
| LPA (min/day) | 303.8 ± 70.5 | 313.0 ± 71.3 | −9.2 (−13.5, −4.8) | <0.01 | 0.983 (0.834, 0.996) ** |
| MPA (min/day) | 71.8 ± 26.9 | 69.4 ± 26.2 | 2.4 (0.9, 3.8) | <0.01 | 0.970 (0.790, 0.992) ** |
| VPA (min/day) | 1.4 ± 1.9 | 1.3 ± 1.8 | 0.1 (−0.1, 0.3) | 0.20 | 0.974 (0.901, 0.992) ** |
| MVPA (min/day) | 73.2 ± 27.4 | 70.7 ± 26.6 | 2.5 (1.0, 4.0) | <0.01 | 0.969 (0.746, 0.992) ** |
| Step counts (steps/day) | 9127.2 ± 2903.4 | 9192.9 ± 2818.8 | −65.7 (−176.5, 45.1) | 0.23 | 0.993 (0.980, 0.998) ** |
| Active workers | |||||
| Wearing time (min/day) | 820.1 ± 88.2 | 822.4 ± 87.0 | −2.3 (−6.3, 1.7) | 0.24 | 0.998 (0.992, 0.999) ** |
| SB (min/day) | 399.6 ± 87.8 | 396.5 ± 89.0 | 3.1 (−2.5, 8.7) | 0.26 | 0.991 (0.950, 0.998) ** |
| LPA (min/day) | 337.3 ± 69.6 | 346.7 ± 68.6 | −9.3 (−14.7, −3.9) | <0.01 | 0.958 (0.806, 0.989) ** |
| MPA (min/day) | 81.1 ± 22.1 | 77.4 ± 21.6 | 3.7 (1.3, 6.1) | <0.01 | 0.996 (0.988, 0.999) ** |
| VPA (min/day) | 2.1 ± 2.3 | 1.8 ± 2.2 | 0.3 (0, 0.5) | <0.05 | 0.944 (0.826, 0.983) ** |
| MVPA (min/day) | 83.2 ± 22.3 | 79.2 ± 21.9 | 4.0 (1.6, 6.3) | <0.01 | 0.996 (0.988, 0.999) ** |
| Step counts (steps/day) | 10,079.7 ± 2585.3 | 10128.6± 2474.1 | −48.9 (−222.6, 124.8) | 0.55 | 0.996 (0.987, 0.999) ** |
| Sedentary workers | |||||
| Wearing time (min/day) | 850.2 ± 100.6 | 848.0 ± 99.5 | 2.2 (−2.0, 6.5) | 0.27 | 0.998 (0.992, 0.999) ** |
| SB (min/day) | 524.0 ± 122.9 | 513.5 ± 129.5 | 10.5 (1.2, 19.7) | <0.05 | 0.991 (0.950, 0.998) ** |
| LPA (min/day) | 264.8 ± 49.9 | 273.7 ± 53.6 | −8.9 (−17.1, −0.8) | <0.05 | 0.958 (0.806, 0.989) ** |
| MPA (min/day) | 60.9 ± 28.8 | 60.1 ± 28.9 | 0.8 (−0.7, 2.4) | 0.27 | 0.996 (0.988, 0.999) ** |
| VPA (min/day) | 0.5 ± 0.9 | 0.6 ± 1.0 | −0.1 (−0.3, 0.1) | 0.37 | 0.944 (0.826, 0.983) ** |
| MVPA (min/day) | 61.5 ± 28.9 | 60.7 ± 29.0 | 0.7 (−0.8, 2.3) | 0.32 | 0.996 (0.988, 0.999) ** |
| Step counts (steps/day) | 8015.9 ± 2959.4 | 8101.2 ± 2900.1 | −85.3 (−245.2, 74.5) | 0.27 | 0.996 (0.987, 0.999) ** |
**p < 0.001. Note: CI = confidence interval, ICC = intra-class correlation coefficients, SB = sedentary behavior, LPA = light physical activity, MPA = moderate physical activity, VPA = vigorous physical activity, MVPA = moderate-to-vigorous physical activity. Values are expressed as the mean ± standard deviation.
Mean of difference and limits of agreement between 750C and 350IT devices.
| Accelerometer Outcomes | Mean Difference | Limits of Agreement |
|
| |
|---|---|---|---|---|---|
| Lower | Upper | ||||
| Total | |||||
| SB (min/day) | 6.5 | 19.2 | −6.2 | −0.13 | 0.53 |
| LPA (min/day) | −9.2 | −27.2 | 8.8 | −0.07 | 0.72 |
| MPA (min/day) | 2.4 | 7.1 | −2.3 | 0.19 | 0.35 |
| VPA (min/day) | 0.1 | 0.3 | −0.1 | 0.35 | 0.08 |
| MVPA (min/day) | 2.5 | 7.4 | −2.4 | 0.19 | 0.34 |
| Step counts (steps/day) | −65.7 | −194.5 | 63.1 | 0.31 | 0.12 |
| Active workers | |||||
| SB (min/day) | 3.1 | 9.2 | −3.0 | −0.12 | 0.68 |
| LPA (min/day) | −9.3 | 27.5 | 8.9 | 0.10 | 0.72 |
| MPA (min/day) | 3.7 | 11.0 | −3.6 | 0.13 | 0.66 |
| VPA (min/day) | 0.3 | 0.9 | −0.3 | 0.37 | 0.20 |
| MVPA (min/day) | 4.0 | 11.8 | −3.8 | 0.10 | 0.74 |
| Step counts (steps/day) | −48.9 | −144.7 | 46.9 | 0.37 | 0.19 |
| Sedentary workers | |||||
| SB (min/day) | 10.5 | 31.1 | −10.1 | −0.46 | 0.13 |
| LPA (min/day) | −8.9 | −26.3 | 8.5 | −0.29 | 0.36 |
| MPA (min/day) | 0.8 | 2.4 | −0.8 | −0.04 | 0.90 |
| VPA (min/day) | −0.1 | −0.3 | 0.1 | −0.36 | 0.25 |
| MVPA (min/day) | 0.7 | 2.1 | −0.7 | −0.06 | 0.86 |
| Step counts (steps/day) | −85.3 | −252.5 | 81.9 | 0.24 | 0.46 |
Note: SB = sedentary behavior, LPA = light physical activity, MPA = moderate physical activity, VPA = vigorous physical activity, MVPA = moderate-to-vigorous physical activity, r = Pearson’s correlation coefficient. Proportional bias indicated in statistical analysis. The mean difference was calculated as follows: 350IT-750C, the upper limits of the agreement were calculated as follows: mean difference + 1.96 standard deviation of the different scores. The lower limits of the agreement were calculated as follows: mean difference – 1.96 standard deviation of the different scores.