Literature DB >> 31054123

The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study.

Hamed Momeni-Moghaddam1,2, Nasim Maddah2, James S Wolffsohn3, Mohammad Etezad-Razavi4, Siamak Zarei-Ghanavati4, Amir Akhavan Rezayat4, Majid Moshirfar5,6,7.   

Abstract

INTRODUCTION: To evaluate the effects of cycloplegia on the biometric components and anterior segment parameters of the eye.
METHODS: In this cross-sectional study, changes to axial length (AL), anterior chamber depth (ACD) lens thickness, anterior chamber angle (ACA) and volume, corneal thickness in the pupil center (PC), corneal curvature (CC) and white-to-white (WTW) following cycloplegia induced by tropicamide 1% in 42 eyes of patients aged 23-58 years were assessed. Biometric components and anterior segment parameters were measured using an IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany) and a Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany), respectively.
RESULTS: Significant statistical changes in ACD (increased by 0.06 ± 0.05 mm; p < 0.001), anterior chamber volume (increased by 15.19 ± 10.32 mm3; p < 0.001), ACA (decreased by 2.18 ± 10.20°; p = 0.029) and lens thickness (decreased by 0.02 ± 0.03 mm; p < 0.001) were observed post-cycloplegia, while the changes in CC, corneal thickness in the PC, WTW and AL were not statistically different (p > 0.05). Also, a significant inferior displacement of the PC along the vertical axes was seen (p = 0.020).
CONCLUSION: Cycloplegia resulted in a deeper ACD and thinner lens thickness. These changes should be considered in determining intraocular lens (IOL) power to prevent refractive surprises in cataract surgery and also in the phakic IOL implantation.

Entities:  

Keywords:  Anterior segment; Biometry; Crystalline lens; Cycloplegia; Ocular components

Year:  2019        PMID: 31054123      PMCID: PMC6692795          DOI: 10.1007/s40123-019-0187-5

Source DB:  PubMed          Journal:  Ophthalmol Ther


Introduction

Nowadays, cycloplegic agents such as tropicamide, homatropine and cyclopentolate have diagnostic and therapeutic applications. These clinical applications include fundus examination, anterior segment assessment, cycloplegic refraction, treatment of uveitis, amblyopia treatment via pharmacological penalization [1], and myopia control in children [2]. Detailed evaluation of the anterior segment is important for corneal refractive surgery, diagnosis and follow-up in patients with glaucoma, intraocular lens (IOL) calculation, and in determining effective lens position in cataract surgery and phakic IOL implantation (pIOL) [1, 3, 4]. Accurate measurement of axial length (AL), anterior chamber depth (ACD) and corneal curvature (CC) is essential for the calculation of IOL power according to different formulas [5, 6]. In addition, white-to-white (WTW) and lens thickness (LT) are necessary items for formulas such as the Holladay II IOL power prediction formula [6]. For example, overestimation of ACD may result in corneal endothelial cell damage [3, 4]. Also, accurate cycloplegic refraction, CC assessment and measurement of central corneal thickness (CCT) are essential in pre- and postoperative assessment of corneal refractive surgery [7]. Assessing ACD is important to determine whether there is enough room for the pIOLs, and the angle dimensions are important especially for an anterior chamber angle (ACA) fixated lens [8]. It is evident that a shallow ACD and/or narrow angle may increase the risk of iris pigment chaffing, particularly when posterior chamber hyperopic pIOLs are implanted [9]. Although several studies have investigated the effects of cycloplegia on the anterior segment parameters and biometry components of the eyes, there are some controversies about the changes in these parameters following cycloplegia [1, 4, 5, 10–12]; a summary of the literature review is presented in Table 1.
Table 1

Comparison of mean change in the biometry components and anterior segment parameters following cycloplegia

StudyCountryAgentDeviceAge range (mean) (years)N (P, E)Mean changes in:
CCT (µm)KRm (D)ACA (°)ACD (mm)ACV(mm3)AL(mm)LT (mm)WTW (mm)
Cheung et al. [13]China (Hong Kong)Cyclopentolate hydrochloride 1%IOLMaster7–15 (10.5)(24, –)0.05*0.00
Bhatia et al. [14]OmanTropicamide 1%A-Scan(24.7)(–, 76)0.25*0.03*−0.21*
Palamar et al. [10]TurkeyCyclopentolate hydrochloride 1%Pentacam6–16 (10.06)(50, –) (right eye data)−19.46*−0.27−0.640.16*17.52*
Huang et al. [5]ChinaTropicamide 0.5% and phenylephrine hydrochloride 0.5%IOLMaster (Lenstar LS900)18–37 (22.1)(43, 43)−0.02 (−0.06)0.06* (0.09*)0.00 (0.00)0.43* (0.10*)
Arici et al. [11]TurkeyCyclopentolate hydrochloride 1%IOLMaster18–28 (23)(25, 25)0.15*0.010.28*
Arriola-Villalobos et al. [6]SpainTropicamide 1%Lenstar LS 90056–90 (74.71)(72, 72)1.120.030.04*0.000.00−0.08
Cheng et al. [2]TaiwanTropicamide 0.4%IOLMaster3–18 (9.1)(114, 114)−0.03*0.07*0.01*
Guler et al. [4]TurkeyCyclopentolate hydrochloride 1%Galilei5–15 (10.27)(50, –) (right eye data)4.645.21*0.10*30.42*
Khambhiphant et al. [15]ThailandTropicamide 1%IOLMaster21–79 (52.39)(195, 384)0.11*0.00
Rodriguez-Raton et al. [16]SpainTropicamide 0.5% and phenylephrine hydrochloride 0.5%IOLMaster56–89 (74.65)(107, 107)0.010.12*0.00
Arriola-Villalobos et al. [17]SpainTropicamide 1%IOLMaster 70057–92 (75.17)(81, 81)2.40*−0.000.04*0.00−0.01*0.03*
Niyaz et al. [3]TurkeyCyclopentolate hydrochloride 1%Galilei3–14 (7.76)(93, –)0.13*31.00*
Ozyol et al. [12]TurkeyCyclopentolate hydrochloride 1%IOLMaster 70024–39 (30.1)(38, 38)3.00*0.13*0.00−0.09*0.00
Ozyol et al. [12]TurkeyCyclopentolate hydrochloride 1%IOLMaster 70047–64 (56.6)(42, 42)1.000.08*0.00−0.02*0.05*

CCT central corneal thickness, KRm mean keratometry reading, ACA anterior chamber angle, ACD anterior chamber depth, ACV anterior chamber volume, AL axial length, LT lens thickness, WTW white-to-white, N number, P patient, E eye

*Significant statistics

Comparison of mean change in the biometry components and anterior segment parameters following cycloplegia CCT central corneal thickness, KRm mean keratometry reading, ACA anterior chamber angle, ACD anterior chamber depth, ACV anterior chamber volume, AL axial length, LT lens thickness, WTW white-to-white, N number, P patient, E eye *Significant statistics This study was designed to assess these variations following induced temporary paralysis of the ciliary muscle and iris sphincter by the cycloplegic agent, tropicamide 1%.

Methods

In this cross-sectional study, 42 eyes of 42 patients with an age range of 23–58 years were assessed. All steps of this study followed the tenets of the Declaration of Helsinki. In addition, the study was approved by the ethics committee of Mashhad University of Medical Sciences. Inclusion criteria were clear central corneas and crystalline lens with no ocular and systemic diseases. Exclusion criteria included history of corneal excimer laser refractive surgery, keratoconus, pellucid marginal degeneration, high myopia 6 D or higher and history of ocular trauma. The refractive status [sphere, cylinder, axis and spherical equivalent (SE)], anterior segment parameters and the ocular biometry were determined using a Topcon auto-kerato-refractometer (Topcon Corp., Tokyo, Japan), Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) and IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany), respectively. The evaluations were repeated after producing the cycloplegic effect. For this purpose, one drop of tropicamide 1% was instilled every 5 min for three applications, and the measurements were repeated 30 min after the last drop. The assessed anterior segment parameters determined using the Pentacam included external ACD (measured from the epithelium), ACA and anterior chamber volume (ACV), corneal thickness at the pupil center (PC) associated with geometric positions of the PC along the horizontal (x) and vertical (y) axes with respect to the corneal apex as the reference point and the corneal diameter (WTW). Ocular biometric parameters included AL, ACD measured from the epithelium and LT. Mean keratometry reading (KRm), and the magnitude and axis of corneal astigmatism (CA) were determined using all three devices, the auto-kerato-refractometer, the Pentacam and the IOLMaster 700. The vector analysis method was used to determine the astigmatic difference between the two states, in which the sphero-cylindrical refraction and CA were transformed to a Jackson crossed-cylinder format, and the refractive data (C: cylinder; α: cylinder axis) were used to calculate J0 and J45, where J0 = (−C/2) cos (2α), and J45 = (−C/2) sin (2α). To compute the astigmatic difference in the two states, the difference between J0 and J45 of the first- and second-state astigmatism was calculated separately. To better understand astigmatic changes, the values of power vector were transformed to the conventional format by applying the following formula: All measurements were done under the supervision of an experienced optometrist who did not have access to the pre-cycloplegic data, in order to prevent any bias or error. All measurements were performed between 6 and 8 p.m. Assessment of the normality of data using the Kolmogorov–Smirnov test showed no normal distribution. Data were analyzed in SPSS 22 software (IBM Corp., Armonk, NY, USA) using the Wilcoxon signed-rank, Kruskal–Wallis and Mann–Whitney U tests. The significance level was considered to be 0.05.

Results

In this study, 42 eyes of 42 patients (28 female and 14 male) were evaluated. The mean age was 35.2 ± 9.4, with a range of 23–58 years. Table 2 presents the refractive status before and after cycloplegia.
Table 2

Mean and standard deviation (SD) of the sphere, cylinder power/axis and spherical equivalent (SE) before and after cycloplegia (n = 42 eyes)

VariablesMean ± SD (95% CI)Wilcoxon signed-rank test
Before cycloplegiaAfter cycloplegia
Sphere (D)−3.23 ± 3.68 (−4.37, −2.08)−2.90 ± 3.68 (−4.05, −1.75)< 0.001
Cylinder (D)−1.44 ± 1.15 (−1.80, −1.08)−1.32 ± 1.12 (−1.67, −0.96)0.139
Axis (°)95.22 ± 64.24 (74.94, 115.50)86.51 ± 65.81 (65.74, 107.29)0.604
SE (D)−2.33 ± 1.82 (−2.90, −1.76)−2.11 ± 1.82 (−2.68, −1.54)< 0.001
Mean and standard deviation (SD) of the sphere, cylinder power/axis and spherical equivalent (SE) before and after cycloplegia (n = 42 eyes) The mean difference seen in the sphere, cylinder, axis and SE was 0.32 ± 0.26 D, 0.11 ± 0.44 D, 8.70° ± 53.82° and 0.22 ± 0.20 D, respectively. Only a significant hyperopic shift was observed in the spherical component (p < 0.001) and SE (p < 0.001), while the magnitude and axis of the refractive cylinder did not change significantly following cycloplegia. Regarding the anterior segment parameters obtained using the Pentacam, cycloplegia induced statistically significant changes in external ACD (p < 0.001), ACV (p < 0.001), ACA (p = 0.029) and the PC along the y-axis (p = 0.020). The ACD and ACV increased, while the ACA decreased post-cycloplegia, with a mean difference of 0.10 ± 0.05 mm, 15.19 ± 10.32 mm3 and −2.18 ± 10.20°, respectively. The PC showed no significant change the x-axis, while a statistically significant change of 0.06 ± 0.17 mm along the y-axis and in the negative direction was observed in comparisons of the locations before and after cycloplegia (Table 3).
Table 3

Mean and standard deviation (SD) of anterior segment parameters using the Pentacam before and after cycloplegia (n = 42 eyes)

VariablesMean ± SD (95% CI)Wilcoxon signed-rank test
Pre-cycloplegiaPost-cycloplegia
ACD (mm)3.63 ± 0.34 (3.52, 3.74)3.73 ± 0.35 (3.62, 3.84)< 0.001
ACA (°)40.08 ± 6.70 (37.99, 42.17)37.89 ± 10.69 (34.56, 41.22)0.029
ACV (mm3)180.69 ± 34.64 (169.89, 191.48)195.88 ± 33.20 (185.53, 206.22)< 0.001
Pachy. @ pupil center (µm)526.33 ± 38.82 (514.23, 538.43)527.42 ± 41.15 (514.60, 540.25)0.066
PCx (mm)−0.01 ± 0.18 (−0.07, 0.03)0.00 ± 0.20 (−0.05, 0.06)0.101
PCy (mm)0.01 ± 0.13 (−0.02, 0.06)−0.04 ± 0.15 (−0.09, 0.00)0.020
WTW (mm)11.94 ± 0.42 (11.80, 12.07)11.98 ± 0.52 (11.82, 12.15)0.123

ACD anterior chamber depth, ACA anterior chamber angle, ACV anterior chamber volume, PCx/PCy geometric positions of the pupil center along the coordinate axes, WTW white-to-white

Mean and standard deviation (SD) of anterior segment parameters using the Pentacam before and after cycloplegia (n = 42 eyes) ACD anterior chamber depth, ACA anterior chamber angle, ACV anterior chamber volume, PCx/PCy geometric positions of the pupil center along the coordinate axes, WTW white-to-white Table 4 shows the mean and standard deviation of the ocular biometry components obtained from the IOLMaster 700 before and after cycloplegia. The mean changes in AL, ACD and LT were 0.0 ± 0.01, 0.06 ± 0.05 and −0.02 ± 0.03 mm, respectively, with no significant change in AL, while ACD significantly increased and LT decreased following cycloplegia.
Table 4

Mean and standard deviation (SD) of ocular biometry components using the IOLMaster 700 before and after cycloplegia (n = 42 eyes)

VariablesMean ± SD (95% CI)Wilcoxon signed-rank test
Pre-cycloplegiaPost-cycloplegia
AL (mm)24.91 ± 1.45 (24.46, 25.36)24.91 ± 1.45 (24.45, 25.36)0.376
ACD (mm)3.60 ± 0.32 (3.49, 3.70)3.66 ± 0.34 (3.55, 3.77)< 0.001
LT (mm)3.76 ± 0.28 (3.67, 3.85)3.74 ± 0.28 (3.65, 3.83)< 0.001

AL axial length, ACD anterior chamber depth, LT lens thickness

Mean and standard deviation (SD) of ocular biometry components using the IOLMaster 700 before and after cycloplegia (n = 42 eyes) AL axial length, ACD anterior chamber depth, LT lens thickness Comparison of the changes in ocular biometry and anterior segment parameters separately in the two age groups, < 40 and ≥ 40 years, only showed a significant difference in LT changes (p = 0.016) (Table 5).
Table 5

Mean and standard deviation (SD) of changes in the ocular biometry and anterior segment parameters separately in two age groups (n = 42 eyes)

Age group component< 40 years (n = 30 eyes)≥ 40 years (n = 12 eyes)Mann–Whitney U test
Mean ± SD (95% CI)Mean ± SD (95% CI)
AL change (mm)0.00 ± 0.01 (0.00, 0.00)0.00 ± 0.00 (0.00, 0.00)0.068
ACD change (mm)0.07 ± 0.03 (0.06, 0.08)0.03 ± 0.08 (−0.01, 0.09)0.945
LT change (mm)−0.03 ± 0.02 (−0.04, −0.02)0.00 ± 0.03 (−0.02, 0.02)0.016
ACA change (°)−2.41 ± 11.43 (−6.68, 1.85)−1.61 ± 6.53 (−5.77, 2.53)0.417
ACV change (mm3)16.03 ± 10.23 (12.21, 19.85)13.08 ± 10.70 (6.28, 19.88)0.731

AL axial length, ACD anterior chamber depth, LT lens thickness, ACA anterior chamber angle, ACV anterior chamber volume

Mean and standard deviation (SD) of changes in the ocular biometry and anterior segment parameters separately in two age groups (n = 42 eyes) AL axial length, ACD anterior chamber depth, LT lens thickness, ACA anterior chamber angle, ACV anterior chamber volume Table 6 presents the mean and standard deviation of the mean KRm and CA using these three devices. A comparison of the mean KRm and CA (magnitude and axis) obtained using these three devices separately pre- and post-cycloplegia showed no significant difference using the Kruskal–Wallis test (p > 0.05). Also, the paired comparison of these variables was not significantly different separately for each device before and after use of tropicamide using the Wilcoxon signed-rank test (p > 0.05).
Table 6

Mean and standard deviation (SD) of mean keratometry (KRm), magnitude and axis of corneal astigmatism (CA) using the Topcon auto-kerato-refractometer, the Pentacam HR and the IOLMaster 700 (n = 42 eyes)

VariablesMean ± SD (95% CI)Kruskal–Wallis test
Topcon auto-kerato-refractometerPentacam HRIOLMaster 700
Mean KRm (D)
 Pre-cycloplegia43.49 ± 2.38 (42.68, 44.30)43.13 ± 3.17 (42.14, 44.12)43.63 ± 2.82 (42.75, 44.51)0.558
 Post-cycloplegia43.46 ± 2.37 (42.65, 44.26)43.15 ± 3.09 (42.19, 44.12)43.69 ± 2.87 (42.78, 44.59)0.566
Wilcoxon signed-rank test0.1390.3620.145
CA (D)
 Pre-cycloplegia1.46 ± 1.04 (1.11, 1.81)1.53 ± 0.98 (1.22, 1.84)1.55 ± 1.03 (1.23, 1.87)0.803
 Post-cycloplegia1.45 ± 1.05 (1.09, 1.80)1.52 ± 0.99 (1.21, 1.83)1.55 ± 1.10 (1.20, 1.90)0.825
Wilcoxon signed-rank test0.8250.7450.148
CA axis (°)
 Pre-cycloplegia92.69 ± 74.15 (67.61, 117.78)94.14 ± 29.25 (85.02, 103.26)77.52 ± 72.02 (55.07, 99.96)0.278
 Post-cycloplegia100.39 ± 73.09 (75.66, 125.12)92.40 ± 31.33 (82.63, 102.16)86.68 ± 72.85 (63.68, 09.68)0.683
Wilcoxon signed-rank test0.7450.1070.251
Mean and standard deviation (SD) of mean keratometry (KRm), magnitude and axis of corneal astigmatism (CA) using the Topcon auto-kerato-refractometer, the Pentacam HR and the IOLMaster 700 (n = 42 eyes) A comparison of ACD measured using the Pentacam HR and IOLMaster 700 showed no significant difference in mean ACD between the two devices using the Mann–Whitney U test separately for before (p = 0.697) and after (p = 0.381) cycloplegia.

Discussion

The results of this study showed significant increase in ACD and ACV, while ACA and LT decreased significantly after producing cycloplegia using tropicamide 1%. Another point was significant displacement of the PC along the vertical axes in the negative direction or inferiorly. As reported, ACD is an important factor in IOL power calculation and diagnosis of primary angle closure glaucoma (PACG), so imprecise measurement may lead to undesirable refractive errors after cataract surgery, reprieve PACG diagnosis and corneal endothelial cell damage following pIOL [1, 3, 14]. The results of this study show a significant increase in ACD and ACV and a decrease in LT following cycloplegia. The results confirm previous studies that reported a significant increase in ACD and ACV after instillation of cycloplegic and mydriatic drops [1, 3, 4, 10]. Rodriguez-Raton et al. [16] found that ACD and IOL, calculated based on the Haigis formula (ACD is used in this formula), were significantly changed after application of tropicamide and phenylephrine, whereas the IOL calculation based on the SRK/T formula was not affected. Similar to the present findings, several studies reported a reduction in LT after cycloplegia [14, 17, 18]. Ocular accommodation increases LT and moves the lens forward [19], while temporary paralysis of the ciliary muscle leads to an increase in ACD by reducing the crystalline lens curvature (flattening) and backward displacement of its geometrical center [7, 12]. Higashiyama et al. [18] reported a significant correlation between the changes in LT and ACD. In contrast to the current study, Arriola-Villalobos et al. [6] reported that changes in LT were not significant after instillation of tropicamide 1% despite a significant increase in ACD. This discrepancy may be attributed to the difference in subject age between these two studies (74.7 ± 7.5 years vs. 35.2 ± 9.4 years in the present study). Although a decrease in the elasticity of the crystalline lens capsule in elderly populations may affect the response to the cycloplegic agents [12], a similar reduction in LT following cycloplegia by tropicamide 1% has been found in an elderly patients (75.2 ± 7.5 years) [17]. The unremarkable effect of cycloplegia on AL in the present study confirms previous studies that showed no significant change in this parameter following mydriasis and/or cycloplegia [7, 11, 13, 15, 20]. On the contrary, there are studies that reported statistically, but not clinically, significant changes in AL following cycloplegia induced by homatropine 2% and cyclopentolate 1% [14]. Similar findings of a significant increase in AL were reported after application of 0.4% tropicamide [2] and in hyperopic eyes, although a considerable reduction was obtained in myopic eyes [21]. Contrary to our research results, Chang et al. [7], Arici et al. [11] and Arriola-Villalobos et al. [17] noted significant widening of WTW after the application of a cycloplegic, although these changes appear to be unverifiable. In the present study, the change in corneal thickness in the PC was not significant, which is in line with previous reports [1, 6, 18]. In contrast to the present findings, however, a significant increase in CCT was cited in the measurement of the effects of cycloplegia on anterior segment parameters with anterior segment optical coherence tomography (AS-OCT) and a Pentacam; this change was attributed to the possible role of reflex tearing and not corneal swelling during measurements [7]. Also, some studies have reported a decrease in CCT in pre-presbyopic eyes [12] and in children after cycloplegia [10]. Some studies reported no significant change in mean KRm following cycloplegia, [6, 10, 20], while others showed a statistically remarkable flattening effect [2, 7]. This flattening was justified based on the paralysis of the ciliary muscle following cycloplegic agents which reduce its force on the sclera spur and lead to the corneal flattening [2]. Assessing the changes in the front and back CC following application of miotic (pilocarpine hydrochloride 2%) and mydriatic (tropicamide/phenylephrine hydrochloride) agents showed significant steepening only in the back surface and significant flattening in both front and back surfaces, respectively [22]. Chang et al. [7] illustrated that flattening in the posterior CC was more in corneas with steeper posterior curvatures. The current study showed no significant change in the mean KRm using the Topcon auto-kerato-refractometer, Pentacam HR and IOLMaster 700 after cycloplegia. With regard to ACA, the present study found a significant narrowing of the angle following cycloplegia, which is in contrast to the results of studies by Niyaz et al. and Guler et al., who reported significant widening of ACA [3, 4], confirming the findings of Arici et al. [1]. As the ACA value is one of the most important factors for diagnosis and follow-up of glaucoma, the effect of cycloplegia on ACA should be considered during examination of patients. Assessing the changes in different ocular biometry and anterior segment parameters before 40 years and above of 40 years affirmed the previous study showing that the changes in LT decrease with age [23]. One limitation of this study was the evaluation of only myopic eyes; therefore, assessing these changes in hyperopic eyes and in a wide range of ages, including children, adults and the elderly, is proposed for future research. Another study limitation is the absence of a control group. In conclusion, cycloplegia resulted in a deeper ACD and thinner LT. These changes should be considered in determining IOL power to prevent refractive surprises in cataract surgery and pIOL implantation.
  23 in total

1.  Effect of pharmacologic pupil dilation on OLCR optical biometry measurements for IOL predictions.

Authors:  Pedro Arriola-Villalobos; David Díaz-Valle; Nuria Garzòn; Jorge Ruiz-Medrano; Cristina Fernández-Perez; Nicolás Alejandre-Alba; Julián García-Feijoò
Journal:  Eur J Ophthalmol       Date:  2013-06-17       Impact factor: 2.597

2.  Effect of cycloplegia on axial length and anterior chamber depth measurements in children.

Authors:  Sin Wan Cheung; Rufina Chan; Roy Cs Cheng; Pauline Cho
Journal:  Clin Exp Optom       Date:  2009-08-31       Impact factor: 2.742

3.  The effect of cycloplegia on the lenstar and the IOLMaster biometry.

Authors:  Jinhai Huang; Colm McAlinden; Binbin Su; Konrad Pesudovs; Yifan Feng; Yanjun Hua; Feng Yang; Chao Pan; Huyong Zhou; Qinmei Wang
Journal:  Optom Vis Sci       Date:  2012-12       Impact factor: 1.973

4.  Accommodative changes in anterior chamber depth in patients with high myopia.

Authors:  Boris E Malyugin; Alexander A Shpak; Dmitry F Pokrovskiy
Journal:  J Cataract Refract Surg       Date:  2012-08       Impact factor: 3.351

5.  The effect of topical 1% cyclopentolate on IOLMaster biometry.

Authors:  Ceyhun Arici; Adem Turk; Osman Melih Ceylan; Mehmet Kola
Journal:  Optom Vis Sci       Date:  2014-11       Impact factor: 1.973

6.  Effect of tropicamide and homatropine eye drops on a-scan parameters of the phakic normal eyes.

Authors:  Jagdish Bhatia
Journal:  Oman Med J       Date:  2011-01

7.  Influences of cyclopentolate hydrochloride on anterior segment parameters with Pentacam in children.

Authors:  Melis Palamar; Sait Egrilmez; Onder Uretmen; Ayse Yagci; Suheyla Kose
Journal:  Acta Ophthalmol       Date:  2011-02-21       Impact factor: 3.761

8.  Changes in the shape of the anterior and posterior corneal surfaces caused by mydriasis and miosis: detailed analysis.

Authors:  Kahori Saitoh; Kenji Yoshida; Yasuhiro Hamatsu; Yutaka Tazawa
Journal:  J Cataract Refract Surg       Date:  2004-05       Impact factor: 3.351

9.  Short-term refractive change and ocular parameter changes after cycloplegia.

Authors:  Han-Chih Cheng; Yi-Ting Hsieh
Journal:  Optom Vis Sci       Date:  2014-09       Impact factor: 1.973

10.  The change in ocular refractive components after cycloplegia in children.

Authors:  Lei Gao; Xuying Zhuo; Alvin K H Kwok; Ning Yu; Lusheng Ma; Jinghua Wang
Journal:  Jpn J Ophthalmol       Date:  2002 May-Jun       Impact factor: 2.447

View more
  2 in total

1.  Effects of Cyclopentolate Hydrochloride Dosage on Anterior Segment Parameters in Young Adults (Measured with Pentacam).

Authors:  Waleed M Alghamdi; Saif H Alrasheed; Vishakh Nair; Muhammed S Alluwimi
Journal:  Clin Ophthalmol       Date:  2021-03-01

2.  Comparison of Simulated and True Keratometry Measurements Using Swept-Source Optical Coherence Tomography and Dual Scheimpflug-Placido Imaging.

Authors:  Elizabeth A Urias; Efstathia Polychronopoulou; Rahul T Pandit
Journal:  J Ophthalmol       Date:  2021-09-16       Impact factor: 1.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.