Literature DB >> 25655597

Effect of pupil dilation on biometry measurements with partial coherence interferometry and its effect on IOL power formula calculation.

Alvaro Rodriguez-Raton1, Marianela Jimenez-Alvarez, Lucia Arteche-Limousin, Estibaliz Mediavilla-Peña, Iñaki Larrucea-Martinez.   

Abstract

PURPOSE: To determine if there are any differences between eye parameters measured by the IOLMaster (Carl Zeiss Meditec AG, Jena, Germany) biometer before and after dilating the pupil. The effect of those changes on intraocular lens (IOL) power calculation is also analyzed.
METHODS: A prospective observational study was carried out including 107 right eyes of 107 patients with cataract and no other ocular morbidity. An IOLMaster baseline measurement included axial length (AL), mean keratometry (K), and anterior chamber depth (ACD) (corneal epithelium to lens). A second measurement was taken 45 minutes after instillation of topical tropicamide and phenylephrine. Biometric variation was analyzed and prediction for IOL power based on the Haigis and the Sanders/Retzlaff/Kraff Theoretical (SRK/T) formulas was calculated for both measurements.
RESULTS: The ACD increased significantly after dilation (+0.12 ± 0.12 mm; p<0.01). The AL and K variation was not significant: +0.00 ± 0.02 mm (p = 0.62) and +0.01 ± 0.22 D (p = 0.57), respectively. Pupil dilation did not affect IOL power calculation based on SRK/T formula either targeting emmetropia (-0.02 ± 0.26, p = 0.30) or the lowest myopic residual refraction (-0.03 ± 0.34, p = 0.30). However, using the Haigis formula significantly changed calculations for emmetropia (0.07 ± 0.34, p = 0.03) and for the lowest myopic refraction (0.10 ± 0.40, p = 0.01).
CONCLUSIONS: Pupil pharmacologic dilation produces a significant increase in ACD when measured by the IOLMaster. This change results in a different IOL power prediction according to the Haigis formula, which calculates the effective lens position taking into account the ACD.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25655597     DOI: 10.5301/ejo.5000568

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  11 in total

1.  Evaluation of impact of posterior phakic IOL implantation on biometry and effectiveness of concomitant use of anterior segment OCT on IOL power calculation for cataract surgery.

Authors:  Masayuki Ouchi
Journal:  J Cataract Refract Surg       Date:  2021-09-01       Impact factor: 3.528

2.  Effect of pupillary dilation on Haigis formula-calculated intraocular lens power measurement by using optical biometry.

Authors:  Bharkbhum Khambhiphant; Suganlaya Sasiwilasagorn; Nattida Chatbunchachai; Krit Pongpirul
Journal:  Clin Ophthalmol       Date:  2016-07-27

3.  Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery.

Authors:  Yubo Wu; Songyu Liu; Rongfeng Liao
Journal:  BMC Ophthalmol       Date:  2017-04-08       Impact factor: 2.209

4.  Influence of pupil dilation on the Barrett universal II (new generation), Haigis (4th generation), and SRK/T (3rd generation) intraocular lens calculation formulas: a retrospective study.

Authors:  Takeshi Teshigawara; Akira Meguro; Nobuhisa Mizuki
Journal:  BMC Ophthalmol       Date:  2020-07-20       Impact factor: 2.209

5.  Influence of pupil dilation on predicted postoperative refraction and recommended IOL to obtain target postoperative refraction calculated by using third- and fourth-generation calculation formulas.

Authors:  Takeshi Teshigawara; Akira Meguro; Nobuhisa Mizuki
Journal:  Clin Ophthalmol       Date:  2018-10-02

6.  Lens anatomy parameters with intraoperative spectral-domain optical coherence tomography in cataractous eyes.

Authors:  Jorge Selem Haddad; Karolinne Maia Rocha; Kaileen Yeh; George Oral Waring
Journal:  Clin Ophthalmol       Date:  2019-02-04

7.  Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients.

Authors:  Jinhai Huang; Yuyu Zhao; Giacomo Savini; Guanshun Yu; Jinjin Yu; Zhongxing Chen; Ruixue Tu; Yune Zhao
Journal:  J Ophthalmol       Date:  2020-05-15       Impact factor: 1.909

8.  Effect of Cycloplegia on Corneal Biometrics and Refractive State.

Authors:  Abbas Bagheri; Mohadeseh Feizi; Aliakbar Shafii; Amir Faramarzi; Mehdi Tavakoli; Shahin Yazdani
Journal:  J Ophthalmic Vis Res       Date:  2018 Apr-Jun

9.  Accuracy of Intraocular Lens Power Calculation Using Anterior Chamber Depth from Two Devices with Barrett Universal II Formula.

Authors:  Hannah Muniz Castro; Audrey X Tai; Samuel J Sampson; Matthew Wade; Marjan Farid; Sumit Garg
Journal:  J Ophthalmol       Date:  2019-09-23       Impact factor: 1.909

10.  The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study.

Authors:  Hamed Momeni-Moghaddam; Nasim Maddah; James S Wolffsohn; Mohammad Etezad-Razavi; Siamak Zarei-Ghanavati; Amir Akhavan Rezayat; Majid Moshirfar
Journal:  Ophthalmol Ther       Date:  2019-05-03
View more