Changes in the shape of the anterior and posterior corneal surfaces caused by mydriasis and miosis: detailed analysis.

Kahori Saitoh1, Kenji Yoshida, Yasuhiro Hamatsu, Yutaka Tazawa.   

Abstract

PURPOSE: To evaluate changes in the anterior and posterior corneal shape, corneal thickness, and anterior chamber depth (ACD) caused by mydriasis or miosis using scanning-slit corneal topography.
SETTING: Department of Ophthalmology, Iwate Medical University School of Medicine, Iwate, Morioka, Japan.
METHODS: Twenty-eight eyes of 28 healthy volunteers with refractive errors of -6.00 to +0.25 diopters were studied. One eye of each subject had instillation of tropicamide-phenylephrine hydrochloride (Mydrin P) to obtain mydriasis and of pilocarpine hydrochloride 2% (Sanpilo) to obtain miosis. To assess the corneal shape, the best-fit sphere (BFS), axial power, and tangential power were measured for the anterior and posterior corneal surfaces before and after mydriasis and before and after miosis using scanning-slit corneal topography (Orbscan version 3.0, Orbtek, Inc.). The pupil size, corneal thickness, and ACD were also examined before and after mydriasis and before and after miosis.
RESULTS: The mean age of the patients was 31.1 years +/- 5.6 (SD) (range 20 to 46 years). The anterior BFS changed from a mean of 8.04 +/- 0.3 mm at the time of mydriasis to a mean of 8.00 +/- 0.3 mm at the time of miosis. The posterior BFS changed from 6.53 +/- 0.3 mm to 6.46 +/- 0.3 mm, respectively. Thus, the anterior and posterior cornea became significantly steeper after miosis (P<.01). The ACD was significantly more shallow after miosis than after mydriasis. However, there was no significant difference in corneal thickness after mydriasis or miosis.
CONCLUSIONS: The anterior and posterior corneal shapes changed as a result of mydriasis and miosis, and the refractive power of the cornea significantly increased after miosis. To date, changes in refractive power from changes in pupil size have been attributed to a change in the refractive power of the crystalline lens; however, it is now thought that changes in corneal refractive power also occur.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15130639     DOI: 10.1016/j.jcrs.2003.10.040

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

Review 1.  [PresbyLASIK: treatment approaches with the excimer laser].

Authors:  K A Becker; A Jaksche; F G Holz
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

2.  Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses.

Authors:  Tomo Nishi; Futoshi Taketani; Tetsuo Ueda; Nahoko Ogata
Journal:  Clin Ophthalmol       Date:  2013-11-01

3.  Effect of Cycloplegia on Keratometric and Biometric Parameters in Keratoconus.

Authors:  Nihat Polat; Abuzer Gunduz
Journal:  J Ophthalmol       Date:  2016-12-12       Impact factor: 1.909

4.  Influence of pupil dilation on predicted postoperative refraction and recommended IOL to obtain target postoperative refraction calculated by using third- and fourth-generation calculation formulas.

Authors:  Takeshi Teshigawara; Akira Meguro; Nobuhisa Mizuki
Journal:  Clin Ophthalmol       Date:  2018-10-02

5.  Effect of pupil dilation on biometric measurements and intraocular lens power calculations in schoolchildren.

Authors:  Xiaogang Wang; Jing Dong; Maolong Tang; Xiaoliang Wang; Haitao Wang; Suhua Zhang
Journal:  PLoS One       Date:  2018-09-13       Impact factor: 3.240

6.  The Effect of Topical Cyclopentolate on Anterior Segment Parameters in Patients with Keratoconus

Authors:  Ahmet Kırgız; Sevil Karaman Erdur; Semih Çakmak; Funda Dikkaya; Rukiye Aydın
Journal:  Turk J Ophthalmol       Date:  2020-03-05

7.  Effect of Cycloplegia on Corneal Biometrics and Refractive State.

Authors:  Abbas Bagheri; Mohadeseh Feizi; Aliakbar Shafii; Amir Faramarzi; Mehdi Tavakoli; Shahin Yazdani
Journal:  J Ophthalmic Vis Res       Date:  2018 Apr-Jun

8.  The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study.

Authors:  Hamed Momeni-Moghaddam; Nasim Maddah; James S Wolffsohn; Mohammad Etezad-Razavi; Siamak Zarei-Ghanavati; Amir Akhavan Rezayat; Majid Moshirfar
Journal:  Ophthalmol Ther       Date:  2019-05-03

9.  Effect of Tropicamide on crystalline Lens rise in low-to-moderate myopic eyes.

Authors:  Zhuoyi Chen; Tao Li; Meiyan Li; Ye Xu; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2020-08-10       Impact factor: 2.209

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.