Literature DB >> 31041522

Outcomes after locked plating of displaced patella fractures: a prospective case series.

Alexander Ellwein1,2, Helmut Lill3, Rony-Orijit DeyHazra3, Tomas Smith4, Jan Christoph Katthagen5.   

Abstract

PURPOSE: Tension band wiring remains a common treatment for patella fractures, but complication rates are high, with unsatisfactory results. The purpose of this observation study was to evaluate clinical results and complication rates of a novel patella locking plate fixation.
METHODS: Twenty patients (mean age, 59.2 ± 18 years) with displaced patella fractures were prospectively enrolled. Range of motion, knee scores (Tegner, Lysholm, Kujala), complications, and revision surgeries were assessed six weeks, six months, 12 months, and 24 months after surgery. Results were compared to the situation before trauma in regards to the time of follow-up using a paired sample t test.
RESULTS: According to the OTA classification, the fractures were classified as follows: one A1, four C1, six C2, and nine C3. Range of motion improved from 121° after six weeks to 140°, 141°, and 143° within the follow-up period. While the Tegner, Lysholm, and Kujala scores were 4.1/97/97, respectively, before trauma, they improved from 2.6/80/89 to 3.6/94/89, 3.7/95/94, and 4.1/97/97 within the follow-up period. Three patients had a complication (15%): one fracture dislocation, one reactive bursitis, and one renewed fracture. Four patients reported discomfort or anterior knee pain especially when kneeling on the implant.
CONCLUSIONS: The patella locking plate is a safe and effective treatment for patella fractures, including comminuted fractures. Function can be restored within six months after surgery, and the complication rate is low. Nonetheless, the implant can cause discomfort or anterior knee pain especially when kneeling, which can necessitate an implant removal.

Entities:  

Keywords:  Complication; Locking plate; Patella fracture; SuturePlate; Tension band wiring

Mesh:

Year:  2019        PMID: 31041522     DOI: 10.1007/s00264-019-04337-7

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  38 in total

1.  The Use of Mesh Plates for Difficult Fractures of the Patella.

Authors:  David Volgas; Tina K Dreger
Journal:  J Knee Surg       Date:  2017-02-13       Impact factor: 2.757

2.  Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures.

Authors:  Simone Wurm; Peter Augat; Volker Bühren
Journal:  J Orthop Trauma       Date:  2015-09       Impact factor: 2.512

3.  Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures.

Authors:  Simon Thelen; Johannes Schneppendahl; Eva Jopen; Christian Eichler; Jürgen Koebke; Eckhard Schönau; Mohssen Hakimi; Joachim Windolf; Michael Wild
Journal:  Injury       Date:  2012-05-17       Impact factor: 2.586

4.  Open fractures of the patella: long-term functional outcome.

Authors:  J B Catalano; W M Iannacone; S Marczyk; R M Dalsey; L S Deutsch; C T Born; W G Delong
Journal:  J Trauma       Date:  1995-09

5.  [Patella dislocation].

Authors:  S Oestern; D Varoga; S Lippross; M Kaschwich; J Finn; B Buddrus; A Seekamp
Journal:  Unfallchirurg       Date:  2011-04       Impact factor: 1.000

6.  Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures.

Authors:  Simon Thelen; Johannes Schneppendahl; Ralf Baumgärtner; Christian Eichler; Jürgen Koebke; Marcel Betsch; Mohssen Hakimi; Joachim Windolf; Michael Wild
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-11       Impact factor: 4.342

7.  Fixed-angle plate osteosynthesis of the patella - an alternative to tension wiring?

Authors:  M Wild; C Eichler; S Thelen; P Jungbluth; J Windolf; M Hakimi
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-01-21       Impact factor: 2.063

8.  Efficacy of various forms of fixation of transverse fractures of the patella.

Authors:  M J Weber; C J Janecki; P McLeod; C L Nelson; J A Thompson
Journal:  J Bone Joint Surg Am       Date:  1980-03       Impact factor: 5.284

9.  The computed tomographic evaluation of patellofemoral joint in patellar fractures treated with open reduction and internal fixation.

Authors:  I T Benli; S Akalin; E F Mumcu; M Citak; M Kiliç; E Paşaoğlu
Journal:  Kobe J Med Sci       Date:  1992-08

10.  Socioeconomic factors and individual lifestyles influencing the incidence of patella fractures: a national population-based survey in China.

Authors:  Yanbin Zhu; Song Liu; Wei Chen; Lin Wang; Xiaolin Zhang; Yingze Zhang
Journal:  Int Orthop       Date:  2018-05-19       Impact factor: 3.075

View more
  10 in total

1.  [Comparative study on the effectiveness of improved and traditional Kirschner wire tension band fixation in treatment of type C patellar fractures].

Authors:  Jian Zhang; Shengyu Wan; Zeli Zhong; Jun Zeng; Chao Wu; Lun Tan; Xu Lin
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-08-15

Review 2.  [Progress in the surgical treatment of the patellar fracture].

Authors:  Guanglei Li; Ping Liu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-08-15

3.  Epidemiology, classification and treatment of patella fractures: an observational study of 3194 fractures from the Swedish Fracture Register.

Authors:  Mark Kruse; Olof Wolf; Sebastian Mukka; Anders Brüggemann
Journal:  Eur J Trauma Emerg Surg       Date:  2022-05-30       Impact factor: 3.693

Review 4.  [Change in the treatment of patellar fractures].

Authors:  Markus T Berninger; Karl-Heinz Frosch
Journal:  Unfallchirurgie (Heidelb)       Date:  2022-04-11

5.  Comminuted AO-C3 fractures of the patella: good outcome using anatomically contoured locking plate fixation.

Authors:  Stefan Buschbeck; Kristina Götz; Alexander Klug; Stefan Barzen; Yves Gramlich; Reinhard Hoffmann
Journal:  Int Orthop       Date:  2022-03-29       Impact factor: 3.479

6.  Plate osteosynthesis in patellar fractures: a systematic review and meta-analysis.

Authors:  Balgovind S Raja; Aakash Jain; Souvik Paul; Arghya Kundu Choudhury; Roop Bhushan Kalia
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-10-19

7.  Reoperation and Complication Rates Following Patellar Fracture Repair with Plates: A Retrospective Analysis with Patient-Reported Outcomes at More than 1 Year of Follow-up.

Authors:  Jake X Checketts; Jared Scott; Keith Fishbeck; Thomas Hart; William Pham; Azad Dadgar; Mark Calder; Brent L Norris
Journal:  JB JS Open Access       Date:  2022-05-12

8.  Influence of patella height after patella fracture on clinical outcome: a 13-year period.

Authors:  Pesch Sebastian; Zyskowski Michael; Greve Frederik; Müller Michael; Wurm Marcus; Crönlein Moritz; Biberthaler Peter; Kirchhoff Chlodwig
Journal:  Arch Orthop Trauma Surg       Date:  2021-04-06       Impact factor: 2.928

9.  A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study.

Authors:  Fuming Wang; Haolan Xiong; Xiaotao Long; Yang Li; Xiaohua Chen; Gang Wang
Journal:  J Orthop Surg Res       Date:  2021-02-01       Impact factor: 2.359

10.  [Current treatment standard for patella fractures in Germany].

Authors:  Kai Fehske; Markus T Berninger; Lena Alm; Reinhard Hoffmann; Johannes Zellner; Clemens Kösters; Stefan Barzen; Michael J Raschke; Kaywan Izadpanah; Elmar Herbst; Christoph Domnick; Jan Philipp Schüttrumpf; Matthias Krause
Journal:  Unfallchirurg       Date:  2020-12-17       Impact factor: 1.000

  10 in total