Literature DB >> 33526054

A precise navigation device for fixation of patella fractures with modified K-wire tension band:a comparative retrospective study.

Fuming Wang1,2, Haolan Xiong3, Xiaotao Long2, Yang Li2, Xiaohua Chen2, Gang Wang4.   

Abstract

BACKGROUND: Traditionally, the technique of modified tension band wires (MTBW) has been the most commonly used surgical procedure. The purpose of this study is to design a precise navigation device that can obtain a standard position of K-wires for (MTBW) and to compare the precise MTBW (P-MTBW) by a navigation device with the conventional MTBW (C-MTBW) by hands in a retrospective study.
METHODS: The device was designed by solidworks2012 software (USA), which could provide a precise guidance for obtaining parallel K-wires. Besides, it could set the distance between two K-wires and the level of K-wires below patellar anterior surface. From June 2014 to August 2018, a total of 112 patients were employed in this retrospective study. The patients were divided into P-MTBW group and C-MTBW group according to the surgical technique with or without the precise navigation device. We needed to record and analyze the operation time and the number of fluoroscopy, postoperative internal fixation imaging, knee function and complications.
RESULTS: There were 54 patients in P-MTBW group and 58 patients in C-MTBW group. There were statistically significant differences (P < 0.001) in the operation time between P-MTBW group (39.5 ± 4.7; range, 32-49 min) and C-MTBW group (53.7 ± 6.8; range, 42-71 min). The number of intraoperative fluoroscopy was significantly less (P < 0.001) in P-MTBW group (4.2 ± 1.4) versus that of C-MTBW group (8.3 ± 2.7). According to Iowa knee score, there was no significant difference (P = 0.268 at 1 year) in function between the two groups. According to our own evaluation criteria for MTBW, anyone in the P-MTBW group was excellent and 26 patients were excellent, 20 patients were good, and 2 patients were fair in the C-MTBW group.
CONCLUSION: The navigation device can reduce operation time and intraoperative fluoroscopy frequency. P-MTBW fixation is an accurate and effective surgical procedure for patella fractures.

Entities:  

Keywords:  Modified K-wire tension band; Navigation device; Patella fractures

Mesh:

Year:  2021        PMID: 33526054      PMCID: PMC7851942          DOI: 10.1186/s13018-021-02235-6

Source DB:  PubMed          Journal:  J Orthop Surg Res        ISSN: 1749-799X            Impact factor:   2.359


  17 in total

1.  Factors affecting the outcomes of modified tension band wiring techniques in transverse patellar fractures.

Authors:  Kai-Lan Hsu; Wei-Lun Chang; Chyun-Yu Yang; Ming-Long Yeh; Chih-Wei Chang
Journal:  Injury       Date:  2017-10-09       Impact factor: 2.586

2.  Comparison of the biomechanical effects of pertrochanteric fixator and dynamic hip screw on an intertrochanteric femoral fracture using the finite element method.

Authors:  Sermet Inal; Ferruh Taspinar; Eyyup Gulbandilar; Kadir Gok
Journal:  Int J Med Robot       Date:  2014-04-29       Impact factor: 2.547

Review 3.  Patellar fractures in adults.

Authors:  J Stuart Melvin; Samir Mehta
Journal:  J Am Acad Orthop Surg       Date:  2011-04       Impact factor: 3.020

4.  Comparison of the cable pin system with conventional open surgery for transverse patella fractures.

Authors:  Ningfang Mao; Deding Liu; Haijian Ni; Hao Tang; Qiulin Zhang
Journal:  Clin Orthop Relat Res       Date:  2013-03-26       Impact factor: 4.176

5.  Transverse fractures of the patella.

Authors:  P A Lotke; M L Ecker
Journal:  Clin Orthop Relat Res       Date:  1981 Jul-Aug       Impact factor: 4.176

6.  Efficacy of various forms of fixation of transverse fractures of the patella.

Authors:  M J Weber; C J Janecki; P McLeod; C L Nelson; J A Thompson
Journal:  J Bone Joint Surg Am       Date:  1980-03       Impact factor: 5.284

7.  Clinical results of treatment using a modified K-wire tension band versus a cannulated screw tension band in transverse patella fractures: A strobe-compliant retrospective observational study.

Authors:  Honglue Tan; Pengyi Dai; Yanhao Yuan
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

8.  Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation.

Authors:  Tien-Yu Yang; Tsan-Wen Huang; Po-Yao Chuang; Kuo-Chin Huang
Journal:  BMC Musculoskelet Disord       Date:  2018-05-24       Impact factor: 2.362

9.  Where should Kirschner wires be placed when fixing patella fracture with modified tension-band wiring? A finite element analysis.

Authors:  Ming Ling; Shi Zhan; Dajun Jiang; Hai Hu; Changqing Zhang
Journal:  J Orthop Surg Res       Date:  2019-01-11       Impact factor: 2.359

10.  Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures.

Authors:  Tao Lin; Junbin Liu; Baojun Xiao; Dehao Fu; Shuhua Yang
Journal:  BMC Musculoskelet Disord       Date:  2015-10-06       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.