INTRODUCTION: Operative treatment of patella fractures is frequently associated with implant failure and secondary dislocation which can be attributed to the employed hardware. Therefore, a 2.7 mm fixed-angle plate designed for the treatment of patella fractures was tested biomechanically against the currently preferred methods of fixation. It was hypothesized that under simulated cyclic loading fixed-angle plating would be superior to modified anterior tension wiring or cannulated lag screws with anterior tension wiring.
MATERIALS AND METHODS: Eighteen human cadaver knees, matched by bone mineral density and age, were divided into three groups of six. After setting a transverse patella fracture each group received one of the osteosyntheses mentioned above. Repetitive testing over 100 cycles was performed at non-destructive loads by simulating knee motion from 90° flexion to full extension.
RESULTS: Anterior tension wiring as well as lag screws with tension wiring showed significant fracture displacement after the initial cycle already. Both constructs, lag screws plus wiring (3.7 ± 2.7 mm) as well as tension wiring alone (7.1 ± 2.2 mm) displayed fracture displacement of >2 mm which is clinically regarded as failure. Those patellae stabilized with fixed-angle plates showed no significant fracture gap widening after completion of 100 cycles (0.7 ± 0.5 mm). The differences between the fixed-angle plate group and the other two groups were statistically significant (p<0.05).
CONCLUSION: In contrast to modified anterior tension wiring and cannulated lag screws with anterior tension wiring the bilateral fixed-angle plate was the only fixation device to stabilize transverse patella fractures securely and sustainably.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22608600     DOI: 10.1016/j.injury.2012.04.020

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  22 in total

1.  [Plate osteosynthesis after patellar fracture - the technique and initial results of a prospective study].

Authors:  A Ellwein; H Lill; G Jensen; A Gruner; J C Katthagen
Journal:  Unfallchirurg       Date:  2017-09       Impact factor: 1.000

2.  Outcomes after locked plating of displaced patella fractures: a prospective case series.

Authors:  Alexander Ellwein; Helmut Lill; Rony-Orijit DeyHazra; Tomas Smith; Jan Christoph Katthagen
Journal:  Int Orthop       Date:  2019-04-30       Impact factor: 3.075

3.  Patella fracture fixation with suture and wire: you reap what you sew.

Authors:  Kenneth Egol; Daniel Howard; Alexa Monroy; Alexander Crespo; Nirmal Tejwani; Roy Davidovitch
Journal:  Iowa Orthop J       Date:  2014

4.  3D reduction combined with the modified Kirschner-wire tension band for the treatment of comminuted patella fracture.

Authors:  Feng Gao; Min Yi; JiaXin Liu; Xiang Zhang; Zhou Xiang; Xin Duan
Journal:  Arch Orthop Trauma Surg       Date:  2022-03-07       Impact factor: 3.067

5.  A New Antirotation Strategy of K-Wire Tension Band Therapy for Patellar Fracture.

Authors:  Fengpo Sun; Yawen Zhang; Quan Ji; Tongyi Zhang; Yi Zhu; Ze Zhang; Ruining Han; Liangyuan Wen
Journal:  Front Surg       Date:  2022-05-10

6.  Functional outcome and economic burden of operative management of patellar fractures: the pivotal role of onerous implants.

Authors:  M Reul; M Verschaeve; T Mennes; S Nijs; H Hoekstra
Journal:  Eur J Trauma Emerg Surg       Date:  2017-09-30       Impact factor: 3.693

7.  Cannulated Screw Prominence in Tension Band Wiring of Patella Fractures Increases Fracture Gapping: A Cadaver Study.

Authors:  Matthew C Avery; Sally Jo; Andrew Chang; William M Ricci; Christopher McAndrew; Anna N Miller; Simon Tang
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

8.  Outcome Analysis of Fixed Angle Locking Plate in Patella Fractures: A Single Centre Experience from North India.

Authors:  Saurabh Singh; Rishabh Surana; Alok Rai; Divyansh Sharma
Journal:  Indian J Orthop       Date:  2020-11-09       Impact factor: 1.251

9.  Suturing methods in prolapse surgery: a biomechanical analysis.

Authors:  J Hachenberg; A Sauerwald; A Prescher; C Eichler; H Brunke; S Ludwig; M Scaal
Journal:  Int Urogynecol J       Date:  2020-12-02       Impact factor: 2.894

10.  Influence of patella height after patella fracture on clinical outcome: a 13-year period.

Authors:  Pesch Sebastian; Zyskowski Michael; Greve Frederik; Müller Michael; Wurm Marcus; Crönlein Moritz; Biberthaler Peter; Kirchhoff Chlodwig
Journal:  Arch Orthop Trauma Surg       Date:  2021-04-06       Impact factor: 2.928

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.