M Wild1, C Eichler, S Thelen, P Jungbluth, J Windolf, M Hakimi. 1. Heinrich Heine University Hospital Düsseldorf, Department of Trauma and Hand Surgery, Moorenstrasse 5, D-40225 Düsseldorf, Germany. post@michaelwild.de
Abstract
BACKGROUND: The goal of this study is carry out a biomechanical evaluation of the stability of a bilateral, polyaxial, fixed-angle 2.7 mm plate system specifically designed for use on the patella. The results of this approach are then compared to the two currently most commonly used surgical techniques for patella fractures: modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring. METHODS: A transient biomechanical analysis determining material failure points of all osteosyntheses were conducted on 21 identical left polyurethane foam patellae, which were osteotomized horizontally. Evaluated were load (N), displacement (mm) and run-time (s) as well as elastic modulus (MPa), tensile strength (MPa) and strain at failure (%). FINDINGS: With a maximum load capacity of 2396 (SD 492) N, the fixed-angle plate proved to be significantly stronger than the cannulated lag screws with anterior tension wiring (1015 (SD 246) N) and the modified anterior tension wiring (625 (SD 84.9) N). The fixed-angle plate displayed significantly greater stiffness and lower fracture gap dehiscence than the other osteosyntheses. Additionally, osteosynthesis deformation was found to be lower for the fixed-angle plate. INTERPRETATION: A bilateral fixed-angle plate was the most rigid and stable osteosynthesis for horizontal patella fractures with the least amount of fracture gap dehiscence. Further biomechanical trials performed under cycling loading with fresh cadaver specimen should be done to figure out if a fixed-angle plate may be an alternative in the surgical treatment of patella fractures. Copyright 2009 Elsevier Ltd. All rights reserved.
BACKGROUND: The goal of this study is carry out a biomechanical evaluation of the stability of a bilateral, polyaxial, fixed-angle 2.7 mm plate system specifically designed for use on the patella. The results of this approach are then compared to the two currently most commonly used surgical techniques for patella fractures: modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring. METHODS: A transient biomechanical analysis determining material failure points of all osteosyntheses were conducted on 21 identical left polyurethane foam patellae, which were osteotomized horizontally. Evaluated were load (N), displacement (mm) and run-time (s) as well as elastic modulus (MPa), tensile strength (MPa) and strain at failure (%). FINDINGS: With a maximum load capacity of 2396 (SD 492) N, the fixed-angle plate proved to be significantly stronger than the cannulated lag screws with anterior tension wiring (1015 (SD 246) N) and the modified anterior tension wiring (625 (SD 84.9) N). The fixed-angle plate displayed significantly greater stiffness and lower fracture gap dehiscence than the other osteosyntheses. Additionally, osteosynthesis deformation was found to be lower for the fixed-angle plate. INTERPRETATION: A bilateral fixed-angle plate was the most rigid and stable osteosynthesis for horizontal patella fractures with the least amount of fracture gap dehiscence. Further biomechanical trials performed under cycling loading with fresh cadaver specimen should be done to figure out if a fixed-angle plate may be an alternative in the surgical treatment of patella fractures. Copyright 2009 Elsevier Ltd. All rights reserved.
Authors: Alexander Ellwein; Helmut Lill; Rony-Orijit DeyHazra; Tomas Smith; Jan Christoph Katthagen Journal: Int Orthop Date: 2019-04-30 Impact factor: 3.075
Authors: Simon Thelen; Johannes Schneppendahl; Ralf Baumgärtner; Christian Eichler; Jürgen Koebke; Marcel Betsch; Mohssen Hakimi; Joachim Windolf; Michael Wild Journal: Knee Surg Sports Traumatol Arthrosc Date: 2012-04-11 Impact factor: 4.342
Authors: Christian Eichler; Julia Schell; Jens Uener; Andreas Prescher; Martin Scaal; Julian Puppe; Mathias Warm Journal: Plast Reconstr Surg Glob Open Date: 2016-03-07
Authors: A Sauerwald; M Niggl; J Puppe; A Prescher; M Scaal; G K Noé; S Schiermeier; M Warm; C Eichler Journal: PLoS One Date: 2016-02-04 Impact factor: 3.240