Literature DB >> 22491707

Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures.

Simon Thelen1, Johannes Schneppendahl, Ralf Baumgärtner, Christian Eichler, Jürgen Koebke, Marcel Betsch, Mohssen Hakimi, Joachim Windolf, Michael Wild.   

Abstract

PURPOSE: A bilateral fixed-angle plate was biomechanically compared to the two currently preferred methods of osteosynthesis for transverse patella fractures. It was hypothesized that the new angle-stable implant would provide a secure and sustainable fracture fixation, superior to the established standard techniques.
METHODS: Twenty-one identical patellae made of polyurethane foam (Sawbones(®)), osteotomized to create a transverse two-part fracture, were fixed with modified anterior tension wiring, cannulated lag screws with anterior tension wiring or bilateral polyaxial 2.7-mm fixed-angle plates. The testing protocol consisted of 10,000 repetitive cycles using a non-destructive physiological load between 100 and 300 N at a simulated knee flexion of 60°.
RESULTS: All 21 Sawbone(®)-patellae sustained repetitive loading up to 10,000 cycles without failing. The anterior tension wire group displayed significant displacement of the fracture gap (0.7 ± 0.2 mm) during cyclic loading, while both lag screws with tension wiring and bilateral fixed-angle plates showed no fracture gap widening at all (p < 0.01).
CONCLUSION: The bilateral fixed-angle plate and cannulated lag screws with anterior tension wiring preserved a constantly reduced fracture gap over 10,000 tensile cycles in contrast to modified anterior tension wiring, which exhibited significant widening of the gap after initial loading. Results of in vitro testing indicate that bilateral fixed-angle plates provide sustainable fixation stability offering a promising new option in the treatment for transverse patella fractures.

Entities:  

Mesh:

Year:  2012        PMID: 22491707     DOI: 10.1007/s00167-012-1999-1

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  36 in total

1.  Fixed-angle plates in patella fractures - a pilot cadaver study.

Authors:  M Wild; Simon Thelen; P Jungbluth; M Betsch; D Miersch; J Windolf; M Hakimi
Journal:  Eur J Med Res       Date:  2011-01-27       Impact factor: 2.175

2.  Fatigue testing of cerclage stainless steel wire fixation.

Authors:  M P Bostrom; S E Asnis; J J Ernberg; T M Wright; V L Giddings; W S Berberian; A A Missri
Journal:  J Orthop Trauma       Date:  1994-10       Impact factor: 2.512

3.  Clinical experience of patellar fracture fixation using metal wire or non-absorbable polyester--a study of 37 cases.

Authors:  H S Gosal; P Singh; R E Field
Journal:  Injury       Date:  2001-03       Impact factor: 2.586

Review 4.  Patellar fractures in adults.

Authors:  J Stuart Melvin; Samir Mehta
Journal:  J Am Acad Orthop Surg       Date:  2011-04       Impact factor: 3.020

5.  Patellar strain and patellofemoral contact after bone-patellar tendon-bone harvest for anterior cruciate ligament reconstruction.

Authors:  N A Sharkey; S W Donahue; T S Smith; B K Bay; R A Marder
Journal:  Arch Phys Med Rehabil       Date:  1997-03       Impact factor: 3.966

6.  Fixed-angle plate osteosynthesis of the patella - an alternative to tension wiring?

Authors:  M Wild; C Eichler; S Thelen; P Jungbluth; J Windolf; M Hakimi
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-01-21       Impact factor: 2.063

7.  Fractures of the patella treated by operation.

Authors:  O Böstman; O Kiviluoto; S Santavirta; J Nirhamo; E Wilppula
Journal:  Arch Orthop Trauma Surg       Date:  1983

8.  Experimental investigation of the tension band in fractures of the patella.

Authors:  A P Fortis; Z Milis; V Kostopoulos; S Tsantzalis; P Kormas; N Tzinieris; Th Boudouris
Journal:  Injury       Date:  2002-07       Impact factor: 2.586

9.  Fractured patella: operative treatment using the tension band principle.

Authors:  L K Hung; K M Chan; Y N Chow; P C Leung
Journal:  Injury       Date:  1985-03       Impact factor: 2.586

10.  Biomechanical comparison of fixation methods in transverse patella fractures.

Authors:  T A Scilaris; J L Grantham; M J Prayson; M P Marshall; J J Hamilton; J L Williams
Journal:  J Orthop Trauma       Date:  1998 Jun-Jul       Impact factor: 2.512

View more
  13 in total

1.  [Plate osteosynthesis after patellar fracture - the technique and initial results of a prospective study].

Authors:  A Ellwein; H Lill; G Jensen; A Gruner; J C Katthagen
Journal:  Unfallchirurg       Date:  2017-09       Impact factor: 1.000

2.  Outcomes after locked plating of displaced patella fractures: a prospective case series.

Authors:  Alexander Ellwein; Helmut Lill; Rony-Orijit DeyHazra; Tomas Smith; Jan Christoph Katthagen
Journal:  Int Orthop       Date:  2019-04-30       Impact factor: 3.075

3.  A cortical screw based tension band construct for transverse patella fractures: An evolving strategy for addressing common modes of failure.

Authors:  Taylor Paziuk; Gerard Chang; Tyler Henry; James Krieg
Journal:  J Orthop       Date:  2022-02-17

4.  A New Antirotation Strategy of K-Wire Tension Band Therapy for Patellar Fracture.

Authors:  Fengpo Sun; Yawen Zhang; Quan Ji; Tongyi Zhang; Yi Zhu; Ze Zhang; Ruining Han; Liangyuan Wen
Journal:  Front Surg       Date:  2022-05-10

5.  A Modified Tension Band Fixation Technique for the Management of Patellar Fractures Using Crossed Pins and a Lateral Parapatellar Approach.

Authors:  Freideriki Poutoglidou; Matija Krkovic
Journal:  Cureus       Date:  2022-04-28

6.  Functional outcome and economic burden of operative management of patellar fractures: the pivotal role of onerous implants.

Authors:  M Reul; M Verschaeve; T Mennes; S Nijs; H Hoekstra
Journal:  Eur J Trauma Emerg Surg       Date:  2017-09-30       Impact factor: 3.693

7.  Outcome Analysis of Fixed Angle Locking Plate in Patella Fractures: A Single Centre Experience from North India.

Authors:  Saurabh Singh; Rishabh Surana; Alok Rai; Divyansh Sharma
Journal:  Indian J Orthop       Date:  2020-11-09       Impact factor: 1.251

8.  Suturing methods in prolapse surgery: a biomechanical analysis.

Authors:  J Hachenberg; A Sauerwald; A Prescher; C Eichler; H Brunke; S Ludwig; M Scaal
Journal:  Int Urogynecol J       Date:  2020-12-02       Impact factor: 2.894

9.  Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures.

Authors:  Tao Lin; Junbin Liu; Baojun Xiao; Dehao Fu; Shuhua Yang
Journal:  BMC Musculoskelet Disord       Date:  2015-10-06       Impact factor: 2.362

10.  Inframammary Fold Reconstruction: A Biomechanical Analysis.

Authors:  Christian Eichler; Julia Schell; Jens Uener; Andreas Prescher; Martin Scaal; Julian Puppe; Mathias Warm
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-03-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.