Literature DB >> 30982341

Influence of the incorporation of a lead foil to intraoral digital receptors on the image quality and root fracture diagnosis.

Amanda Farias Gomes1, Yuri Nejaim1, Rocharles Cavalcante Fontenele1, Francisco Haiter-Neto1, Deborah Queiroz Freitas1.   

Abstract

OBJECTIVE: To evaluate the quality of images obtained with the addition of a lead foil to intraoral digital receptors.
METHODS: Radiographic images of 34 single-rooted human teeth - 19 with vertical root fracture (VRF) and 15 of the control group - were obtained with and without the addition of a lead foil, using the VistaScan, Express, Digora Optime and Digora Toto systems. Images were evaluated by five observers regarding the diagnosis of VRF, using a 5-point scale. In a second moment, an observer preference analysis related to the presence of the lead foil was performed. Images of an acrylic phantom were also obtained with and without the addition of a lead foil, and the quantities of uniformity, grey value and standard deviation of grey values were obtained.
RESULTS: There were no significant differences in the VRF diagnostic values, considering the presence of the lead foil. Regarding the image quality preference, the observers preferred images acquired with the lead foil for all systems tested, but with greater values for Digora Optime (61.33%) and Express (61.33%). The presence of the lead foil did influence the image uniformity in all systems tested ( p < 0.05). Moreover, the lead foil increased the mean of grey values for Digora Optime and Express images ( p < 0.05), however it did not influence the SD in any of the digital systems ( p > 0.05).
CONCLUSION: The addition of a lead foil to intraoral digital receptors produces a positive effect in the image quality objectively detected by means of uniformity and subjective visual preference.

Entities:  

Keywords:  Dental digital radiography; image enhancement; tooth fractures.

Mesh:

Year:  2019        PMID: 30982341      PMCID: PMC6747444          DOI: 10.1259/dmfr.20180369

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  23 in total

1.  Performance evaluation and testing of digital intra-oral radiographic systems.

Authors:  P Doyle; L Finney
Journal:  Radiat Prot Dosimetry       Date:  2006-02-03       Impact factor: 0.972

2.  The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics.

Authors:  Bart Vandenberghe; Marius Bud; Asti Sutanto; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2009-05-19       Impact factor: 3.573

3.  Evaluation of image quality parameters of representative intraoral digital radiographic systems.

Authors:  Hema Udupa; Peter Mah; Stephen B Dove; William D McDavid
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2013-12

Review 4.  Work flow with digital intraoral radiography: a systematic review.

Authors:  Ann Wenzel; Anne Møystad
Journal:  Acta Odontol Scand       Date:  2010-03       Impact factor: 2.331

5.  The usage of digital radiography and cone beam computed tomography among Turkish dentists.

Authors:  Semanur Dölekoğlu; E Fişekçioğlu; M İlgüy; D İlgüy
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

6.  Effect of combined digital imaging parameters on endodontic file measurements.

Authors:  Matheus Lima de Oliveira; Geraldo Camilo de Souza Pinto; Glaucia Maria Bovi Ambrosano; Guilherme Monteiro Tosoni
Journal:  J Endod       Date:  2012-07-10       Impact factor: 4.171

7.  High resolution charge-coupled device sensor vs. medium resolution photostimulable phosphor plate digital receptors for detection of root fractures in vitro.

Authors:  Ann Wenzel; Lise-Lotte Kirkevang
Journal:  Dent Traumatol       Date:  2005-02       Impact factor: 3.333

8.  Comparison of digital with conventional radiography in detection of vertical root fractures in endodontically treated maxillary premolars: an ex vivo study.

Authors:  Igor Tsesis; Kivanc Kamburoğlu; Alexander Katz; Aviad Tamse; Israel Kaffe; Anda Kfir
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-03-04

9.  The 'Sharpen' filter improves the radiographic detection of vertical root fractures.

Authors:  H A R Nascimento; A C A Ramos; F S Neves; S L de-Azevedo-Vaz; D Q Freitas
Journal:  Int Endod J       Date:  2014-07-07       Impact factor: 5.264

Review 10.  Vertical root fractures and their management.

Authors:  Sandhya Anand Khasnis; Krishnamurthy Haridas Kidiyoor; Anand Basavaraj Patil; Smita Basavaraj Kenganal
Journal:  J Conserv Dent       Date:  2014-03
View more
  2 in total

1.  Does the addition of a lead foil to digital radiographic receptors influence image contrast and approximal caries lesions diagnosis?

Authors:  Rocharles Cavalcante Fontenele; Yuri Nejaim; Amanda Farias Gomes; Hugo Gaêta-Araujo; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2020-02-06       Impact factor: 2.419

2.  Benefits of using a photostimulable phosphor plate protective device.

Authors:  Graziela de Moura; Mariana Boessio Vizzotto; Priscila Fernanda da Silveira Tiecher; Nádia Assein Arús; Heraldo Luis Dias da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2021-01-08       Impact factor: 3.525

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.