Literature DB >> 22980188

Effect of combined digital imaging parameters on endodontic file measurements.

Matheus Lima de Oliveira1, Geraldo Camilo de Souza Pinto, Glaucia Maria Bovi Ambrosano, Guilherme Monteiro Tosoni.   

Abstract

INTRODUCTION: This study assessed the effect of the combination of a dedicated endodontic filter, spatial resolution, and contrast resolution on the determination of endodontic file lengths.
METHODS: Forty extracted single-rooted teeth were x-rayed with K-files (ISO size 10 and 15) in the root canals. Images were acquired using the VistaScan system (Dürr Dental, Beitigheim-Bissingen, Germany) under different combining parameters of spatial resolution (10 and 25 line pairs per millimeter [lp/mm]) and contrast resolution (8- and 16-bit depths). Subsequently, a dedicated endodontic filter was applied on the 16-bit images, creating 2 additional parameters. Six observers measured the length of the endodontic files in the root canals using the software that accompanies the system. The mean values of the actual file lengths and the measurements of the radiographic images were submitted to 1-way analysis of variance and the Tukey test at a level of significance of 5%. The intraobserver reproducibility was assessed by the intraclass correlation coefficient.
RESULTS: All combined image parameters showed excellent intraobserver agreement with intraclass correlation coefficient means higher than 0.98. The imaging parameter of 25 lp/mm and 16 bit associated with the use of the endodontic filter did not differ significantly from the actual file lengths when both file sizes were analyzed together or separately (P > .05). When the size 15 file was evaluated separately, only 8-bit images differed significantly from the actual file lengths (P ≤ .05).
CONCLUSIONS: The combination of an endodontic filter with high spatial resolution and high contrast resolution is recommended for the determination of file lengths when using storage phosphor plates.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2012        PMID: 22980188     DOI: 10.1016/j.joen.2012.06.006

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  5 in total

1.  Effect of Contrast Inversion Enhancement on the Accuracy of Endodontic File Length Determination in Digital Radiography.

Authors:  Nastaran Farhadi; Ali Shokraneh; Mojdeh Mehdizadeh
Journal:  J Clin Diagn Res       Date:  2015-05-01

2.  Exploring digital filters for internal root resorption: how can we improve the diagnosis of small lesions?

Authors:  Priscila Fernanda da Silveira Tiecher; Nádia Assein Arús; Eduarda Adams Hilgert; Heloisa Emilia Dias da Silveira; Mathias Pante Fontana; Heraldo Luís Dias da Silveira; Mariana Boessio Vizzotto
Journal:  Dentomaxillofac Radiol       Date:  2021-11-23       Impact factor: 3.525

3.  Influence of the incorporation of a lead foil to intraoral digital receptors on the image quality and root fracture diagnosis.

Authors:  Amanda Farias Gomes; Yuri Nejaim; Rocharles Cavalcante Fontenele; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2019-05-08       Impact factor: 2.419

4.  The influence of different scan resolutions on the detection of proximal caries lesions.

Authors:  Liana Matos Ferreira; Polyane Mazucatto Queiroz; Gustavo Machado Santaella; Ann Wenzel; Francisco Carlos Groppo; Francisco Haiter-Neto
Journal:  Imaging Sci Dent       Date:  2019-06-24

5.  Evaluation of the combined assessment of two digital enhancement filters in periapical radiographs obtained with different projection angles in the detection of simulated dental root fractures.

Authors:  Victor Aquino Wanderley; Matheus L Oliveira; Ana Lidia Pinheiro Silva; Guilherme Monteiro Tosoni
Journal:  Oral Radiol       Date:  2021-06-30       Impact factor: 1.852

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.