Literature DB >> 20141365

Work flow with digital intraoral radiography: a systematic review.

Ann Wenzel1, Anne Møystad.   

Abstract

OBJECTIVE: This systematic review evaluates the six most frequently emphasized advantages of working with digital radiography: less working time, lower radiation dose to the patient, fewer retakes and errors, wider dynamic range, easier access to patient information and easier image storage and communication. Moreover, some clinical aspects and possible disadvantages of digital imaging that were not foreseen at the beginning of the digital era, such as patient discomfort, damage to the receptor, degradation of the image, cross-contamination and viewing conditions, were assessed.
MATERIAL AND METHODS: The literature search used the PubMed database with no limits and was performed during June to August 2009. Search strategies are described in the text for each of the mentioned tasks. A hand search of task-specific journals supplemented the search strategies.
RESULTS: Time seems to be saved when switching from film to digital imaging in dental practice, a dose reduction may not be obtained, retakes and errors may be increased, the dynamic range may be wider with photostimulable storage phosphor (PSP) plates but not with sensors, the effect on patient information has not been well studied and storage and communication create new challenges with regard to handling large files and image compression. In addition, patient discomfort seems to be pronounced with sensors compared with PSP plates and film, the PSP plate may be scratched in clinical use and a two-layer barrier seems to be needed to prevent contamination of the receptor. The type of monitor may not be of major concern if the image is viewed in a room with subdued light.
CONCLUSIONS: Not all of the predicted advantages with digital compared to film-based radiography hold true in daily clinical work. Of particular interest is the relationship between number of images, retakes and the dose given to the patient.

Entities:  

Mesh:

Year:  2010        PMID: 20141365     DOI: 10.3109/00016350903514426

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  34 in total

1.  Effect of ambient light level at the monitor surface on digital radiographic evaluation of approximal carious lesions: an in vitro study.

Authors:  K Hellén-Halme; A Lith
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

2.  Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth.

Authors:  Elif Sogur; B Güniz Baksı; Kaan Orhan; S Candan Paksoy; Salih Dogan; Yılmaz S Erdal; Ali Mert
Journal:  Clin Oral Investig       Date:  2010-09-14       Impact factor: 3.573

3.  Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields.

Authors:  Anna Kelaranta; Marja Ekholm; Paula Toroi; Mika Kortesniemi
Journal:  Dentomaxillofac Radiol       Date:  2015-08-27       Impact factor: 2.419

4.  The usage of digital radiography and cone beam computed tomography among Turkish dentists.

Authors:  Semanur Dölekoğlu; E Fişekçioğlu; M İlgüy; D İlgüy
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

5.  Fractal analysis of periapical bone from lossy compressed radiographs: a comparison of two lossy compression methods.

Authors:  B Güniz Baksi; Aleš Fidler
Journal:  J Digit Imaging       Date:  2011-12       Impact factor: 4.056

6.  Efficacy of lead foil for reducing doses in the head and neck: a simulation study using digital intraoral systems.

Authors:  Y Nejaim; A I V Silva; D M Brasil; K F Vasconcelos; F Haiter Neto; F N Boscolo
Journal:  Dentomaxillofac Radiol       Date:  2015-06-18       Impact factor: 2.419

7.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

8.  Influence of the image file format of digital periapical radiographs on the diagnosis of external and internal root resorptions.

Authors:  Murilo Miranda-Viana; Daniela Verardi Madlum; Nicolly Oliveira-Santos; Hugo Gaêta-Araujo; Francisco Haiter-Neto; Matheus L Oliveira
Journal:  Clin Oral Investig       Date:  2021-01-26       Impact factor: 3.573

9.  Imaging evaluating of the implant/bone interface-an in vitro radiographic study.

Authors:  Michele M Vidor; Gabriela S Liedke; Mariana B Vizzotto; Heraldo L D da Silveira; Priscila F da Silveira; Cristiano W Araujo; Heloisa E D da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2017-03-28       Impact factor: 2.419

10.  Definition, classification and retrospective analysis of photostimulable phosphor image artefacts and errors in intraoral dental radiography.

Authors:  Armağan Çalışkan; A Pinar Sumer
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.