Literature DB >> 15660754

High resolution charge-coupled device sensor vs. medium resolution photostimulable phosphor plate digital receptors for detection of root fractures in vitro.

Ann Wenzel1, Lise-Lotte Kirkevang.   

Abstract

The aim of this study was to compare the diagnostic accuracy of a high resolution charge-coupled device (CCD) sensor and a medium resolution photostimulable phosphor (PSP) plate for detecting experimentally induced root fractures and further, to evaluate differences between images taken with various horizontal and vertical angles. Forty-seven extracted single-rooted human teeth mounted in a dry human skull were used in the experiment. The teeth were radiographed, before and after root fractures were induced, with two digital receptors: the Digora PSP system (approx. 8 lp mm(-1)) and the RVG-ui(TM), a CCD sensor with a high-resolution mode (15-20 lp mm(-1)). Four images were taken with each of the receptors of each tooth: one orthogonal exposure (O-images), one exposure with a vertical angle of 15 degrees by which the root was imaged elongated (L-images), and two eccentric exposures with a horizontal angle of 15 degrees mesially and distally. Three observers marked a fracture line if detected, in each image. Three sessions were held, one assessing the O-images, one the L-images, and one in which all four images of the same tooth were displayed simultaneously (X-images). The RVG-ui images obtained higher sensitivities than the Digora PSP images (P <0.05). Sensitivity was statistically significantly higher for the X-images than for both the O-images and the L-images (P <0.05). Based on the observed means, specificities were significantly different neither between the angles, nor between the images from the two digital systems taken with the same angle (P >0.05). It may be speculated that the difference in spatial resolution between the two digital systems accounts for the differences in their sensitivity.

Entities:  

Mesh:

Year:  2005        PMID: 15660754     DOI: 10.1111/j.1600-9657.2004.00258.x

Source DB:  PubMed          Journal:  Dent Traumatol        ISSN: 1600-4469            Impact factor:   3.333


  8 in total

1.  Assessment of vertical root fractures using three imaging modalities: cone beam CT, intraoral digital radiography and film.

Authors:  J Kambungton; A Janhom; S Prapayasatok; S Pongsiriwet
Journal:  Dentomaxillofac Radiol       Date:  2012-02       Impact factor: 2.419

2.  Detection of experimentally induced root fractures on digital and conventional radiographs: an in vitro study.

Authors:  Athena Kondylidou-Sidira; Anastasia Fardi; Michaela Giannopoulou; Nikolaos Parisis
Journal:  Odontology       Date:  2012-01-15       Impact factor: 2.634

3.  Comparison of intraoral radiography and cone-beam computed tomography for the detection of horizontal root fractures: an in vitro study.

Authors:  Hakan Avsever; Kaan Gunduz; Kaan Orhan; Ismail Uzun; Bilal Ozmen; Erol Egrioglu; Muhammed Midilli
Journal:  Clin Oral Investig       Date:  2013-02-09       Impact factor: 3.573

4.  Influence of the incorporation of a lead foil to intraoral digital receptors on the image quality and root fracture diagnosis.

Authors:  Amanda Farias Gomes; Yuri Nejaim; Rocharles Cavalcante Fontenele; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2019-05-08       Impact factor: 2.419

5.  Diagnosis of alveolar and root fractures: an in vitro study comparing CBCT imaging with periapical radiographs.

Authors:  Solange Kobayashi-Velasco; Fernanda Cristina Sales Salineiro; Ivan Onone Gialain; Marcelo Gusmão Paraiso Cavalcanti
Journal:  J Appl Oral Sci       Date:  2017 Mar-Apr       Impact factor: 2.698

6.  Accuracy of digital image enhancement in detection of vertical and horizontal root fracture.

Authors:  Maryam Ghazizadeh; Mahnaz Sheikhi; Maedeh Aminian; Mohammad Moein Ghazizadeh
Journal:  Dent Res J (Isfahan)       Date:  2020-08-14

7.  In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT).

Authors:  Erdogan Fisekcioglu; Semanur Dolekoglu; Mehmet Ilguy; Nilufer Ersan; Dilhan Ilguy
Journal:  Iran J Radiol       Date:  2014-01-30       Impact factor: 0.212

8.  In Vitro Comparison of Cone Beam Computed Tomography with Digital Periapical Radiography for Detection of Vertical Root Fracture in Posterior Teeth.

Authors:  Mehrdad Abdinian; Hamid Razavian; Nastaran Jenabi
Journal:  J Dent (Shiraz)       Date:  2016-06
  8 in total