Literature DB >> 30808011

Dosimetric accuracy of dynamic couch rotation during volumetric modulated arc therapy (DCR-VMAT) for primary brain tumours.

Gregory Smyth1, Philip M Evans, Jeffrey C Bamber, Henry C Mandeville, A Rollo Moore, Liam C Welsh, Frank H Saran, James L Bedford.   

Abstract

Radiotherapy treatment plans using dynamic couch rotation during volumetric modulated arc therapy (DCR-VMAT) reduce the dose to organs at risk (OARs) compared to coplanar VMAT, while maintaining the dose to the planning target volume (PTV). This paper seeks to validate this finding with measurements. DCR-VMAT treatment plans were produced for five patients with primary brain tumours and delivered using a commercial linear accelerator (linac). Dosimetric accuracy was assessed using point dose and radiochromic film measurements. Linac-recorded mechanical errors were assessed by extracting deviations from log files for multi-leaf collimator (MLC), couch, and gantry positions every 20 ms. Dose distributions, reconstructed from every fifth log file sample, were calculated and used to determine deviations from the treatment plans. Median (range) treatment delivery times were 125 s (123-133 s) for DCR-VMAT, compared to 78 s (64-130 s) for coplanar VMAT. Absolute point doses were 0.8% (0.6%-1.7%) higher than prediction. For coronal and sagittal films, respectively, 99.2% (96.7%-100%) and 98.1% (92.9%-99.0%) of pixels above a 20% low dose threshold reported gamma  <1 for 3% and 3 mm criteria. Log file analysis showed similar gantry rotation root-mean-square error (RMSE) for VMAT and DCR-VMAT. Couch rotation RMSE for DCR-VMAT was 0.091° (0.086-0.102°). For delivered dose reconstructions, 100% of pixels above a 5% low dose threshold reported gamma  <1 for 2% and 2 mm criteria in all cases. DCR-VMAT, for the primary brain tumour cases studied, can be delivered accurately using a commercial linac.

Entities:  

Mesh:

Year:  2019        PMID: 30808011      PMCID: PMC6877349          DOI: 10.1088/1361-6560/ab0a8e

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  41 in total

1.  Continuous arc rotation of the couch therapy for the delivery of accelerated partial breast irradiation: a treatment planning analysis.

Authors:  Simona F Shaitelman; Leonard H Kim; Di Yan; Alvaro A Martinez; Frank A Vicini; Inga S Grills
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-30       Impact factor: 7.038

2.  Monte Carlo based, patient-specific RapidArc QA using Linac log files.

Authors:  Tony Teke; Alanah M Bergman; William Kwa; Bradford Gill; Cheryl Duzenli; I Antoniu Popescu
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

3.  A modular approach to intensity-modulated arc therapy optimization with noncoplanar trajectories.

Authors:  Dávid Papp; Thomas Bortfeld; Jan Unkelbach
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

Review 4.  Challenges in calculation of the gamma index in radiotherapy - Towards good practice.

Authors:  M Hussein; C H Clark; A Nisbet
Journal:  Phys Med       Date:  2017-03-14       Impact factor: 2.685

5.  Dynamic trajectory-based couch motion for improvement of radiation therapy trajectories in cranial SRT.

Authors:  R Lee MacDonald; Christopher G Thomas
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

6.  Quality control procedures for dynamic treatment delivery techniques involving couch motion.

Authors:  Victoria Y Yu; Benjamin P Fahimian; Lei Xing; Dimitre H Hristov
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

7.  Dynamic intensity-modulated non-coplanar arc radiotherapy (INCA) for head and neck cancer.

Authors:  Jerôme Krayenbuehl; J Bernard Davis; I Frank Ciernik
Journal:  Radiother Oncol       Date:  2006-10-19       Impact factor: 6.280

8.  Machine-specific quality assurance procedure for stereotactic treatments with dynamic couch rotations.

Authors:  Byron Wilson; Ermias Gete
Journal:  Med Phys       Date:  2017-10-23       Impact factor: 4.071

9.  Trajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy.

Authors:  Gregory Smyth; Jeffrey C Bamber; Philip M Evans; James L Bedford
Journal:  Phys Med Biol       Date:  2013-11-21       Impact factor: 3.609

10.  Quality control of VMAT synchronization using portal imaging.

Authors:  James L Bedford; Honorata Chajecka-Szczygielska; Michael D R Thomas
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

View more
  4 in total

1.  Many-isocenter optimization for robotic radiotherapy.

Authors:  Qihui Lyu; Ryan Neph; Victoria Y Yu; Dan Ruan; Salime Boucher; Ke Sheng
Journal:  Phys Med Biol       Date:  2020-02-10       Impact factor: 3.609

2.  Organ-at-risk sparing with dynamic trajectory radiotherapy for head and neck cancer: comparison with volumetric arc therapy on a publicly available library of cases.

Authors:  Jenny Bertholet; Paul-Henry Mackeprang; Silvan Mueller; Gian Guyer; Hannes A Loebner; Yanick Wyss; Daniel Frei; Werner Volken; Olgun Elicin; Daniel M Aebersold; Michael K Fix; Peter Manser
Journal:  Radiat Oncol       Date:  2022-07-15       Impact factor: 4.309

3.  Dosimetric accuracy of delivering SBRT using dynamic arcs on Cyberknife.

Authors:  James L Bedford; Simeon Nill; Uwe Oelfke
Journal:  Med Phys       Date:  2020-03-03       Impact factor: 4.071

4.  Treatment planning optimization with beam motion modeling for dynamic arc delivery of SBRT using Cyberknife with multileaf collimation.

Authors:  James L Bedford; Henry S Tsang; Simeon Nill; Uwe Oelfke
Journal:  Med Phys       Date:  2019-10-22       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.