Literature DB >> 28410677

Challenges in calculation of the gamma index in radiotherapy - Towards good practice.

M Hussein1, C H Clark2, A Nisbet3.   

Abstract

The gamma index (γ) is one of the most commonly used metrics for the verification of complex modulated radiotherapy. The mathematical definition of the γ is computationally expensive and various techniques have been reported to speed up the calculation either by mathematically refining the γ or employing various computational techniques. These techniques can cause variation in output with different software implementations. The γ has traditionally been used to compare a 2D measured plane against a 2D or 3D dose distribution. Recently, software algorithm and hardware improvements have led to the possibility of using measured 2D data from commercial detector arrays to reconstruct a 3D-dose distribution and perform a volumetric comparison against the treatment planning system (TPS). A limitation in this approach is that commercial detector arrays have so far been limited by their spatial resolution which may affect the accuracy of the reconstructed 3D volume and subsequently the γ calculation. Additionally, 3D versus 3D γ comparison adds a layer of complication in the calculation of the γ given the increase in the number of calculation points and the result cannot be as easily interpreted in the same way as 2D comparison. This review summarises and highlights the computational challenges of the γ calculation and sheds light on some of these issues by means of a bespoke MATLAB software to demonstrate the impact of interpolation, γ search distance, resolution and 2D and 3D calculations. Finally, a recommendation is made on the minimum information that should be reported when publishing γ results.
Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Keywords:  Detector arrays; Gamma index; IMRT; MATLAB; Quality assurance; VMAT

Mesh:

Year:  2017        PMID: 28410677     DOI: 10.1016/j.ejmp.2017.03.001

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  15 in total

1.  Dosimetric accuracy of dynamic couch rotation during volumetric modulated arc therapy (DCR-VMAT) for primary brain tumours.

Authors:  Gregory Smyth; Philip M Evans; Jeffrey C Bamber; Henry C Mandeville; A Rollo Moore; Liam C Welsh; Frank H Saran; James L Bedford
Journal:  Phys Med Biol       Date:  2019-04-05       Impact factor: 3.609

2.  Comparison of global and local gamma evaluation results using isodose levels.

Authors:  Liting Yu; Tanya Kairn; Jamie V Trapp; Scott B Crowe
Journal:  Phys Eng Sci Med       Date:  2021-02-08

3.  Monte Carlo Calculation of the Energy Spectrum of a 6 MeV Electron Beam using PENetration and Energy Loss of Positrons and Electrons Code.

Authors:  Danny Giancarlo Apaza Veliz; Jorge Homero Wilches Visbal; Felipe Chen Abrego; José Luis Vega Ramírez
Journal:  J Med Phys       Date:  2020-07-20

4.  Validation of Monte carlo Geant4 multithreading code for a 6 MV photon beam of varian linac on the grid computing.

Authors:  Assalmi Mustapha; Diaf El Yamani; Mansour Najim
Journal:  Rep Pract Oncol Radiother       Date:  2020-10-12

5.  Survey results of 3D-CRT and IMRT quality assurance practice.

Authors:  Hunter Mehrens; Paige Taylor; David S Followill; Stephen F Kry
Journal:  J Appl Clin Med Phys       Date:  2020-04-30       Impact factor: 2.102

6.  Improving accuracy for stereotactic body radiotherapy treatments of spinal metastases.

Authors:  James Rijken; Barry Jordan; Scott Crowe; Tanya Kairn; Jamie Trapp
Journal:  J Appl Clin Med Phys       Date:  2018-06-26       Impact factor: 2.102

7.  A comprehensive and clinical-oriented evaluation criteria based on DVH information and gamma passing rates analysis for IMRT plan 3D verification.

Authors:  Xin Yi; Wen-Li Lu; Jun Dang; Wei Huang; Hai-Xia Cui; Wan-Chun Wu; Ying Li; Qing-Feng Jiang
Journal:  J Appl Clin Med Phys       Date:  2020-05-20       Impact factor: 2.102

8.  Assessment of MRI-Based Attenuation Correction for MRI-Only Radiotherapy Treatment Planning of the Brain.

Authors:  Iiro Ranta; Jarmo Teuho; Jani Linden; Riku Klén; Mika Teräs; Mika Kapanen; Jani Keyriläinen
Journal:  Diagnostics (Basel)       Date:  2020-05-14

9.  Evaluation of Delta4DVH Anatomy in 3D Patient-Specific IMRT Quality Assurance.

Authors:  Du Tang; Zhen Yang; Xunzhang Dai; Ying Cao
Journal:  Technol Cancer Res Treat       Date:  2020 Jan-Dec

10.  Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer.

Authors:  Yuri Jeong; Jeong Geun Oh; Jeong Ku Kang; Sun Rock Moon; Kang Kyoo Lee
Journal:  Radiat Oncol J       Date:  2020-03-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.