Literature DB >> 30730198

Comparison of BALP, CTX-I, and IL-4 levels around miniscrew implants during orthodontic tooth movement between two different amounts of force.

Mine Gecgelen Cesur, V Ozgen Ozturk, Beral Afacan, F Burcu Sirin, Afra Alkan, Torun Ozer.   

Abstract

OBJECTIVES: To evaluate the Interleukin-4 (IL-4), bone-specific alkaline phosphatase (BALP), and C-telopeptide of type I collagen (CTX-I) levels in peri-miniscrew crevicular fluid (PMCF) during orthodontic tooth movement between 75 and 150 g of distalization force.
MATERIALS AND METHODS: Thirty miniscrews were placed bilaterally between the maxillary second premolars and first molars. The right and the left maxillary canines were moved distally using either 75 or 150 g of force. PMCF samples were collected before loading (T0); at 2 hours (T1) and 24 hours (T2) later; and on days 7 (T3), 14 (T4), 21 (T5), 30 (T6), and 90 (T7) after force application. Enzyme-linked immunosorbent assay kits were used to determine BALP, CTX-I, and IL-4 levels.
RESULTS: There was no significant difference between the force groups at all time points with respect to BALP, CTX-I, and IL-4 levels (P > .05). There was no significant difference among time points for the two force groups in terms of BALP and IL-4 levels (P > .05). The CTX-I level at T3 was significantly higher than at T0 for both force groups (P < .05).
CONCLUSIONS: Both 75 g and 150 g of orthodontic force are within optimal force limits, and there is no difference in biochemical markers of bone turnover.

Entities:  

Keywords:  Miniscrew; Orthodontic force; Peri-miniscrew crevicular fluid

Mesh:

Substances:

Year:  2019        PMID: 30730198      PMCID: PMC8117201          DOI: 10.2319/071718-520.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  27 in total

1.  IL-4 inhibits TNF-α-mediated osteoclast formation by inhibition of RANKL expression in TNF-α-activated stromal cells and direct inhibition of TNF-α-activated osteoclast precursors via a T-cell-independent mechanism in vivo.

Authors:  Toshiya Fujii; Hideki Kitaura; Keisuke Kimura; Zaki Weli Hakami; Teruko Takano-Yamamoto
Journal:  Bone       Date:  2012-07-06       Impact factor: 4.398

2.  OPG and RANKL levels around miniscrew implants during orthodontic tooth movement.

Authors:  Sukru Enhos; Ilknur Veli; Omer Cakmak; Faruk Izzet Ucar; Arzu Alkan; Tancan Uysal
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-08       Impact factor: 2.650

3.  Is there an optimal force level for sutural expansion?

Authors:  Sean Shih-Yao Liu; Lynne A Opperman; Hee-Moon Kyung; Peter H Buschang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-04       Impact factor: 2.650

4.  A clinical investigation of the concepts of differential and optimal force in canine retraction.

Authors:  C H Boester; L E Johnston
Journal:  Angle Orthod       Date:  1974-04       Impact factor: 2.079

5.  A laminagraphic study of cuspid retraction versus molar anchorage loss.

Authors:  R C Paulson; T M Speidel; R J Isaacson
Journal:  Angle Orthod       Date:  1970-01       Impact factor: 2.079

6.  Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage.

Authors:  Shouichi Miyawaki; Isao Koyama; Masahide Inoue; Katsuaki Mishima; Toshio Sugahara; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-10       Impact factor: 2.650

7.  Intrusion of multiradicular teeth and related root resorption with mini-screw implant anchorage: a radiographic evaluation.

Authors:  Roberto Carrillo; P Emile Rossouw; Pedro F Franco; Lynne A Opperman; Peter H Buschang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-11       Impact factor: 2.650

8.  Comparison of rate of canine retraction with conventional molar anchorage and titanium implant anchorage.

Authors:  Badri Thiruvenkatachari; Pavithranand Ammayappan; Rajasigamani Kandaswamy
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-07       Impact factor: 2.650

9.  Effect of interleukin-4 on orthodontic tooth movement and associated root resorption.

Authors:  Zaki Hakami; Hideki Kitaura; Keisuke Kimura; Masahiko Ishida; Haruki Sugisawa; Hiroto Ida; Saeed Jafari; Teruko Takano-Yamamoto
Journal:  Eur J Orthod       Date:  2014-07-29       Impact factor: 3.075

10.  The integration of orthodontic miniscrews under mechanical loading: a pre-clinical study in rabbit.

Authors:  B Giuliano Maino; Alberto Di Blasio; Davide Spadoni; Francesca Ravanetti; Carlo Galli; Antonio Cacchioli; Christos Katsaros; Mauro Gandolfini
Journal:  Eur J Orthod       Date:  2017-10-01       Impact factor: 3.075

View more
  2 in total

1.  Tissue-specific biomarkers in gingival crevicular fluid are correlated with external root resorption caused by constant mechanical load: an in vivo study.

Authors:  Gui-Yue Huang; Sung-Hwan Choi; Hwi-Dong Jung; Hyun Sil Kim; Chung-Ju Hwang; Kee-Joon Lee
Journal:  Clin Oral Investig       Date:  2021-04-06       Impact factor: 3.573

Review 2.  Profiles of inflammation factors and inflammatory pathways around the peri-miniscrew implant.

Authors:  Wendan He; Huazhang Zhu; Chufeng Liu
Journal:  Histol Histopathol       Date:  2021-04-09       Impact factor: 2.303

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.