Literature DB >> 28339580

The integration of orthodontic miniscrews under mechanical loading: a pre-clinical study in rabbit.

B Giuliano Maino1, Alberto Di Blasio1, Davide Spadoni2, Francesca Ravanetti3, Carlo Galli1, Antonio Cacchioli3, Christos Katsaros4, Mauro Gandolfini1.   

Abstract

INTRODUCTION: Orthodontic miniscrews are an increasingly popular choice to achieve absolute anchorage. The temporary use of miniscrews and their recent introduction have limited the debate over the biological aspect of the materials to that of the surface that permeates the field of dental implants. The aim of the present study was to investigate the integration of grade 5 titanium mini-implants with machined or sand blasted acid etched surface (SAE) under mechanical load in a rabbit tibia model of implant integration.
METHODS: A total of 64 miniscrews (Ti6Al4V) of 1.5 mm diameter and 6.5 mm length were inserted in the proximal medial surface of each tibia in eight male rabbits aged 6 months. Each tibia received four miniscrews. A 100 g nickel-titanium coil spring (Neosentalloy) was applied between two miniscrews along the main axis while two miniscrews were left unloaded. The removal torque was measured for loaded and unloaded miniscrews after 12 weeks. Two miniscrews were harvested for histology.
RESULTS: Removal torque was significantly higher for SAE mini-implants than for machined screws, under both loading conditions. Although no difference in bone to implant contact was observed among the groups, cortical area significantly decreased with both surfaces under loading.
CONCLUSIONS: Our data indicate that SAE miniscrews have higher bone retention than MA miniscrews, although the effects of mechanical loading of these devices on cortical bone require further investigations.
© The Author 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28339580     DOI: 10.1093/ejo/cjw069

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  3 in total

1.  Comparison of BALP, CTX-I, and IL-4 levels around miniscrew implants during orthodontic tooth movement between two different amounts of force.

Authors:  Mine Gecgelen Cesur; V Ozgen Ozturk; Beral Afacan; F Burcu Sirin; Afra Alkan; Torun Ozer
Journal:  Angle Orthod       Date:  2019-02-07       Impact factor: 2.079

Review 2.  Implant-bone-interface: Reviewing the impact of titanium surface modifications on osteogenic processes in vitro and in vivo.

Authors:  Theresia Stich; Francisca Alagboso; Tomáš Křenek; Tomáš Kovářík; Volker Alt; Denitsa Docheva
Journal:  Bioeng Transl Med       Date:  2021-07-12

3.  Effect of surface treatment on the mechanical stability of orthodontic miniscrews.

Authors:  Yousef Al-Thomali; Sakeenabi Basha; Roshan Noor Mohamed
Journal:  Angle Orthod       Date:  2022-01-01       Impact factor: 2.079

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.