OPG and RANKL levels around miniscrew implants during orthodontic tooth movement.

Sukru Enhos1, Ilknur Veli, Omer Cakmak, Faruk Izzet Ucar, Arzu Alkan, Tancan Uysal.   

Abstract

INTRODUCTION: The aim of this study was to determine the peri-miniscrew implant crevicular fluid receptor activator of nuclear factor-кB ligand (RANKL) and osteoprotegerin (OPG) levels around loaded and unloaded miniscrew implants at different time intervals.
METHODS: Twenty loaded and 16 unloaded miniscrew implants were included in this study. All miniscrew implants were placed bilaterally between the maxillary second premolars and first molars as anchorage units for canine distalization. Peri-miniscrew implant crevicular fluid was taken from the mesiobuccal aspects of the loaded and unloaded miniscrew implants before loading; at 24, 48, and 168 hours; and on day 30 after force application. Enzyme-linked immunosorbent assay kits were used to determine RANKL and OPG levels in the peri-miniscrew implant crevicular fluid samples. Wilcoxon, Mann-Whitney U, and Spearman correlation tests were used for statistical evaluations at the P <0.05 level.
RESULTS: Although the total amount of OPG was not different between the groups, the total amount of RANKL was significantly elevated in the loaded miniscrew implant group (P <0.05) at all time periods. Peri-miniscrew implant crevicular fluid volume was the highest at 48 hours in the loaded group. Also, the OPG/RANKL ratio in the peri-miniscrew implant crevicular fluid was significantly decreased in the loaded miniscrew implant group.
CONCLUSIONS: The OPG and RANKL levels vary around loaded and unloaded miniscrew implants as a result of force application.
Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23910201     DOI: 10.1016/j.ajodo.2013.02.028

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  6 in total

1.  Comparison of BALP, CTX-I, and IL-4 levels around miniscrew implants during orthodontic tooth movement between two different amounts of force.

Authors:  Mine Gecgelen Cesur; V Ozgen Ozturk; Beral Afacan; F Burcu Sirin; Afra Alkan; Torun Ozer
Journal:  Angle Orthod       Date:  2019-02-07       Impact factor: 2.079

2.  Evaluation of RANK, RANKL and OPG Levels in Gingival Crevicular Fluid After Surgically Assisted Rapid Maxillary Expansion.

Authors:  Onur Berkün; Yavuz Fındık; Orhan Akpınar; Zuhal Yetkin Ay; Timuçin Baykul
Journal:  J Maxillofac Oral Surg       Date:  2021-01-04

3.  Levels of TGF-β1 in peri-miniscrew implant crevicular fluid.

Authors:  Avinash Kaur; Om Prakash Kharbanda; Moganty R Rajeswari; Dinesh Kalyanasundaram
Journal:  J Oral Biol Craniofac Res       Date:  2020-03-06

Review 4.  Profiles of inflammation factors and inflammatory pathways around the peri-miniscrew implant.

Authors:  Wendan He; Huazhang Zhu; Chufeng Liu
Journal:  Histol Histopathol       Date:  2021-04-09       Impact factor: 2.303

Review 5.  A review of biomarkers in peri-miniscrew implant crevicular fluid (PMICF).

Authors:  Avinash Kaur; Om P Kharbanda; Priyanka Kapoor; Dinesh Kalyanasundaram
Journal:  Prog Orthod       Date:  2017-11-27       Impact factor: 2.750

6.  Expression and Presence of OPG and RANKL mRNA and Protein in Human Periodontal Ligament with Orthodontic Force.

Authors:  Liliana Otero; Dabeiba Adriana García; Liseth Wilches-Buitrago
Journal:  Gene Regul Syst Bio       Date:  2016-01-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.