Literature DB >> 30714011

An endoscopic surgical technique for treating radiculopathy secondary to S1 nerve compression from a pedicle screw: technical note.

Ralf Wagner1, Albert E Telfeian2.   

Abstract

Pedicle screw instrumentation is a widely used technique for fixating the spine in fusion surgery. One of the complications associated with pedicle screw placement is when a screw breaches the pedicle medially and causes the patient radicular pain or numbness or weakness. Revising a breached pedicle screw in a patient who has undergone a multilevel fusion surgery often requires that the patient undergo a very invasive revision surgical procedure. Here the authors present a technical note on decompressing an S1 nerve compressed by a breached pedicle screw by performing an endoscopic surgical approach through a 1-cm incision and drilling down the threads of the pedicle screw, directly decompressing the nerve without removing the screw.

Entities:  

Keywords:  Endoscopic spine surgery; laminectomy; minimally-invasive spine; pedicle screw; radiculopathy

Year:  2018        PMID: 30714011      PMCID: PMC6330589          DOI: 10.21037/jss.2018.11.03

Source DB:  PubMed          Journal:  J Spine Surg        ISSN: 2414-4630


  17 in total

1.  Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases.

Authors:  Jonathan S Hott; Vivek R Deshmukh; Jeffrey D Klopfenstein; Volker K H Sonntag; Curtis A Dickman; Robert F Spetzler; Stephen M Papadopoulos
Journal:  Neurosurgery       Date:  2004-05       Impact factor: 4.654

2.  Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement.

Authors:  Yoshimoto Ishikawa; Tokumi Kanemura; Go Yoshida; Zenya Ito; Akio Muramoto; Shuichiro Ohno
Journal:  J Neurosurg Spine       Date:  2010-11

3.  Clinical accuracy of computer-assisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws.

Authors:  Bheeshma Ravi; Ali Zahrai; Raja Rampersaud
Journal:  Spine (Phila Pa 1976)       Date:  2011-01-01       Impact factor: 3.468

4.  A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws.

Authors:  Gregory P Lekovic; Eric A Potts; Dean G Karahalios; Graham Hall
Journal:  J Neurosurg Spine       Date:  2007-10

5.  Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion.

Authors:  Yasuo Ito; Yoshihisa Sugimoto; Masao Tomioka; Yasuhiro Hasegawa; Kie Nakago; Yukihisa Yagata
Journal:  J Neurosurg Spine       Date:  2008-11

Review 6.  The accuracy of pedicle screw placement using intraoperative image guidance systems.

Authors:  Alexander Mason; Renee Paulsen; Jason M Babuska; Sharad Rajpal; Sigita Burneikiene; E Lee Nelson; Alan T Villavicencio
Journal:  J Neurosurg Spine       Date:  2013-12-20

7.  Transforaminal endoscopic solution to disk reherniation post-mini-TLIF: case report.

Authors:  Albert E Telfeian
Journal:  Clin Neurol Neurosurg       Date:  2015-02-11       Impact factor: 1.876

8.  Learning curve of 3D fluoroscopy image-guided pedicle screw placement in the thoracolumbar spine.

Authors:  Yu-Mi Ryang; Jimmy Villard; Thomas Obermüller; Benjamin Friedrich; Petra Wolf; Jens Gempt; Florian Ringel; Bernhard Meyer
Journal:  Spine J       Date:  2014-10-12       Impact factor: 4.166

9.  Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion.

Authors:  Yoshimoto Ishikawa; Tokumi Kanemura; Go Yoshida; Akiyuki Matsumoto; Zenya Ito; Ryoji Tauchi; Akio Muramoto; Shuichiro Ohno; Yusuke Nishimura
Journal:  J Neurosurg Spine       Date:  2011-07-15

Review 10.  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques.

Authors:  Ioannis D Gelalis; Nikolaos K Paschos; Emilios E Pakos; Angelos N Politis; Christina M Arnaoutoglou; Athanasios C Karageorgos; Avraam Ploumis; Theodoros A Xenakis
Journal:  Eur Spine J       Date:  2011-09-07       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.