Literature DB >> 30671337

A comparative evaluation of cyclic fatigue resistance for different endodontic NiTi rotary files: An in-vitro study.

Akanksha Bhatt1, Balakrishnan Rajkumar2.   

Abstract

AIM: This in-vitro study evaluated and compared the flexural fatigue resistance for Hero Shapers, Hyflex CM, One Shape, Profile Vortex and Protaper Next rotary NiTi files. METHOD AND MATERIALS: Total 25 rotary NiTi files allocated to each experimental group were tested in a simulated constructed apparatus with an angle of curvature 60° & radius of curvature 5 mm. Each experimental file was coated with EDTA gel and was placed in endodomotor handpiece with rubber stopper at support steel cylinder and its end between two shaping steel cylinders on the simulated apparatus. File was then rotated at 400 rpm, 2.5 N/cm torque and simultaneously digital stop watch was started. Time taken (in seconds) until the file got fractured was recorded.
RESULTS: Time taken to fracture ranged from 7 to 58 s in different groups. Analysis of variance show a statistically significant intergroup difference (p < 0.001). Tukey HSD test showed the significant differences. The Weibull modulus values ranged from 7.31 to 24.19.
CONCLUSION: Cyclic flexural fatigue resistance was observed highest for Grp IV (Hyflex CM) and lowest for Grp I (Hero Shapers). CLINICAL SIGNIFICANCE: Hyflex CM rotary NiTi files can be used in curved root canals as they had superior resistance and long survival time which will be helpful in eliminating one of the reasons for file fracture (due to cyclic flexural fatigue) during the root canal treatment clinically where root canal possesses a sharp bend or curve.

Entities:  

Keywords:  Cyclic fatigue; Flexural fatigue; Rotary NiTi files; Static flexural fracture resistance

Year:  2019        PMID: 30671337      PMCID: PMC6327874          DOI: 10.1016/j.jobcr.2018.12.003

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  16 in total

1.  Influence of rotational speed, torque and operator's proficiency on ProFile failures.

Authors:  G M Yared; F E Bou Dagher; P Machtou
Journal:  Int Endod J       Date:  2001-01       Impact factor: 5.264

2.  Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments.

Authors:  Y Haïkel; R Serfaty; G Bateman; B Senger; C Allemann
Journal:  J Endod       Date:  1999-06       Impact factor: 4.171

3.  Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests.

Authors:  Uei-Ming Li; Bor-Shiunn Lee; Chin-Tsai Shih; Wan-Hong Lan; Chun-Pin Lin
Journal:  J Endod       Date:  2002-06       Impact factor: 4.171

4.  Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use.

Authors:  Peter Parashos; Ian Gordon; Harold H Messer
Journal:  J Endod       Date:  2004-10       Impact factor: 4.171

5.  Defects in ProTaper S1 instruments after clinical use: longitudinal examination.

Authors:  B Peng; Y Shen; G S P Cheung; T J Xia
Journal:  Int Endod J       Date:  2005-08       Impact factor: 5.264

6.  Failure mechanism of ProTaper Ni-Ti rotary instruments during clinical use: fractographic analysis.

Authors:  A P Spanaki-Voreadi; N P Kerezoudis; S Zinelis
Journal:  Int Endod J       Date:  2006-03       Impact factor: 5.264

7.  Comparison of defects in ProFile and ProTaper systems after clinical use.

Authors:  Ya Shen; Gary Shun-pan Cheung; Zhuan Bian; Bin Peng
Journal:  J Endod       Date:  2006-01       Impact factor: 4.171

Review 8.  Rotary NiTi instrument fracture and its consequences.

Authors:  Peter Parashos; Harold H Messer
Journal:  J Endod       Date:  2006-11       Impact factor: 4.171

9.  The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue.

Authors:  Spiros Zinelis; Myrsini Darabara; Toshiyuki Takase; Kaoru Ogane; George D Papadimitriou
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2007-04-11

10.  Defects in rotary nickel-titanium files after clinical use.

Authors:  B Sattapan; G J Nervo; J E Palamara; H H Messer
Journal:  J Endod       Date:  2000-03       Impact factor: 4.171

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.