Literature DB >> 10530246

Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments.

Y Haïkel1, R Serfaty, G Bateman, B Senger, C Allemann.   

Abstract

The absence of adequate testing standards for engine-driven nickel-titanium (NiTi) instruments necessitates further study of these instruments in all areas. This study examined three groups of engine-driven rotary NiTi endodontic instruments (Profile, Hero, and Quantec) and assessed the times for dynamic fracture in relation to the radius of curvature to which the instruments were subjected during preparation, with the instrument diameter determined by size and taper and the mode by which the fracture occurred. Ten instruments were randomly selected representing each size and taper for each group and for each radius of curvature: 600 in total. The instruments were rotated at 350 rpm and introduced into a tempered steel curve that simulated a canal. Two radii of curvature of canals were used: 5 and 10 mm. Time at fracture was noted for all files, and the fracture faces of each file were analyzed with scanning electron microscopy. Radius of curvature was found to be the most significant factor in determining the fatigue resistance of the files. As radius of curvature decreased, fracture time decreased. Taper of files was found to be significant in determining fracture time. As diameter increased, fracture time decreased. In all cases, fracture was found to be of a ductile nature, thus implicating cyclic fatigue as a major cause of failure and necessitating further analyses and setting of standards in this area.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10530246     DOI: 10.1016/S0099-2399(99)80274-X

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  18 in total

1.  Influence of axial movement on fatigue of ProFile Ni-Ti rotary instruments: an in vitro evaluation.

Authors:  Marie-Chantal Avoaka; Youssef Haïkel
Journal:  Bosn J Basic Med Sci       Date:  2010-05       Impact factor: 3.363

2.  Postoperative pain after endodontic treatment of necrotic teeth submitted to large apical preparation using oscillatory kinematics.

Authors:  Ricardo Machado; Daniel Comparin; Sérgio-Aparecido Ignácio; Ulisses-Xavier-da Silva Neto
Journal:  J Clin Exp Dent       Date:  2022-02-01

3.  Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files.

Authors:  Tyler Sobotkiewicz; Xiangya Huang; Markus Haapasalo; Christophe Mobuchon; Ahmed Hieawy; Jinghao Hu; Huimin Zhou; Zhejun Wang; Ya Shen
Journal:  Clin Oral Investig       Date:  2020-06-02       Impact factor: 3.573

4.  A comparative evaluation of cyclic fatigue resistance for different endodontic NiTi rotary files: An in-vitro study.

Authors:  Akanksha Bhatt; Balakrishnan Rajkumar
Journal:  J Oral Biol Craniofac Res       Date:  2019-01-02

5.  An in vitro cyclic fatigue resistance comparison of conventional and new generation nickel-titanium rotary files.

Authors:  Celia Ruiz-Sánchez; Vicente Faus-Matoses; Teresa Alegre-Domingo; Ignacio Faus-Matoses; Vicente-José Faus-Llácer
Journal:  J Clin Exp Dent       Date:  2018-08-01

6.  Shot peening increases resistance to cyclic fatigue fracture of endodontic files.

Authors:  Javier Nino-Barrera; Jose Sanchez-Aleman; Manuel Acosta-Humanez; Luis Gamboa-Martinez; Carlos Cortes-Rodriguez
Journal:  Sci Rep       Date:  2021-06-21       Impact factor: 4.379

7.  Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions.

Authors:  Ok-In Cho; Antheunis Versluis; Gary Sp Cheung; Jung-Hong Ha; Bock Hur; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2013-02-26

8.  An in vitro comparison of cyclic fatigue resistance of ProTaper universal and GT series X files.

Authors:  Ramiro Montenegro-Santillán; Teresa Alegre-Domingo; Vicente Faus-Matoses; Vicente Faus-Llácer
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-05-01

9.  Influence of cervical preflaring on apical transportation in curved root canals instrumented by reciprocating file systems.

Authors:  Neisiana Barbieri; Denise Piotto Leonardi; Marina Samara Baechtold; Gisele Maria Correr; Marilisa Carneiro Leão Gabardo; João César Zielak; Flares Baratto-Filho
Journal:  BMC Oral Health       Date:  2015-11-23       Impact factor: 2.757

10.  Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system.

Authors:  Károly Krajczár; Enikő Varga; Gyula Marada; Sára Jeges; Vilmos Tóth
Journal:  J Clin Exp Dent       Date:  2016-04-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.