Literature DB >> 22570506

Virtual nonenhanced dual-energy CT urography with tin-filter technology: determinants of detection of urinary calculi in the renal collecting system.

Stefanie Mangold1, Christoph Thomas, Michael Fenchel, Morten Vuust, Bernhard Krauss, Dominik Ketelsen, Ilias Tsiflikas, Claus D Claussen, Martin Heuschmid.   

Abstract

PURPOSE: To retrospectively determine which features of urinary calculi are associated with their detection after virtual elimination of contrast medium at dual-energy computed tomographic (CT) urography by using a novel tin filter.
MATERIALS AND METHODS: The institutional ethics committee approved this retrospective study, with waiver of informed consent. A total of 152 patients were examined with single-energy nonenhanced CT and dual-energy CT urography in the excretory phase (either 140 and 80 kV [n=44] or 140 and 100 kV [n=108], with tin filtration at 140 kV). The contrast medium in the renal pelvis and ureters was virtually removed from excretory phase images by using postprocessing software, resulting in virtual nonenhanced (VNE) images. The sensitivity regarding the detection of calculi on VNE images compared with true nonenhanced (TNE) images was determined, and interrater agreement was evaluated by using the Cohen k test. By using logistic regression, the influences of image noise, attenuation, and stone size, as well as attenuation of the contrast medium, on the stone detection rate were assessed. Threshold values with maximal sensitivity and specificity were calculated by means of receiver operating characteristic analyses.
RESULTS: Eighty-seven stones were detected on TNE images; 46 calculi were identified on VNE images (sensitivity, 52.9%). Interrater agreement revealed a κ value of 0.95 with TNE images and 0.91 with VNE data. Size (long-axis diameter, P=.005; short-axis diameter, P=.041) and attenuation (P=.0005) of the calculi and image noise (P=.0031) were significantly associated with the detection rate on VNE images. As threshold values, size larger than 2.9 mm, maximum attenuation of the calculi greater than 387 HU, and image noise less than 20 HU were found.
CONCLUSION: After virtual elimination of contrast medium, large (>2.9 mm) and high-attenuation (>387 HU) calculi can be detected with good reliability; smaller and lower attenuation calculi might be erased from images, especially with increased image noise. © RSNA, 2012.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22570506     DOI: 10.1148/radiol.12110851

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  15 in total

1.  Urinary stone detection and characterisation with dual-energy CT urography after furosemide intravenous injection: preliminary results.

Authors:  Diomidis Botsikas; Catrina Hansen; Salvatore Stefanelli; Christoph D Becker; Xavier Montet
Journal:  Eur Radiol       Date:  2013-10-02       Impact factor: 5.315

2.  Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT.

Authors:  Julian L Wichmann; Andrew D Hardie; U Joseph Schoepf; Lloyd M Felmly; Jonathan D Perry; Akos Varga-Szemes; Stefanie Mangold; Damiano Caruso; Christian Canstein; Thomas J Vogl; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

3.  Initial exploration of coronary stent image subtraction using dual-layer spectral CT.

Authors:  Le Qin; ShengJia Gu; ChiHua Chen; Huan Zhang; ZhenBin Zhu; XingBiao Chen; Qun Han; FuHua Yan; WenJie Yang
Journal:  Eur Radiol       Date:  2019-01-21       Impact factor: 5.315

4.  [Imaging for diagnostics of urolithiasis including dual-energy CT].

Authors:  F Strittmatter; C Gratzke; A Graser; C G Stief; T R C Johnson
Journal:  Urologe A       Date:  2013-04       Impact factor: 0.639

5.  Can virtual non-enhanced CT be used to replace true non-enhanced CT for the detection of palpable cervical lymph nodes? A preliminary study.

Authors:  Yaying Yang; Xiaoxia Jia; Yamin Deng; Jiuhong Chen; Long Jiang Zhang
Journal:  Jpn J Radiol       Date:  2014-04-19       Impact factor: 2.374

6.  Dual energy CT in patients with acute abdomen; is it possible for virtual non-enhanced images to replace true non-enhanced images?

Authors:  A Lan Im; Young Hwan Lee; Dong Ho Bang; Kwon Ha Yoon; Sang Hyun Park
Journal:  Emerg Radiol       Date:  2013-07-03

7.  Dual-energy computed tomography after endovascular aortic aneurysm repair: the role of hard plaque imaging for endoleak detection.

Authors:  R Müller-Wille; T Borgmann; W A Wohlgemuth; F Zeman; K Pfister; E M Jung; P Heiss; A G Schreyer; B Krauss; C Stroszczynski; C Dornia
Journal:  Eur Radiol       Date:  2014-06-26       Impact factor: 5.315

8.  Limited added utility of performing follow-up contrast-enhanced CT in patients undergoing initial non-enhanced CT for evaluation of flank pain in the emergency department.

Authors:  Monica D Agarwal; Robin B Levenson; Bettina Siewert; Marc A Camacho; Vassilios Raptopoulos
Journal:  Emerg Radiol       Date:  2014-08-01

Review 9.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Joel G Fletcher
Journal:  Radiology       Date:  2015-09       Impact factor: 11.105

10.  Single-phase DECT with VNCT compared with three-phase CTU in patients with haematuria.

Authors:  Jung Jae Park; Byung Kwan Park; Chan Kyo Kim
Journal:  Eur Radiol       Date:  2016-02-16       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.