Literature DB >> 23351817

Head-to-head comparison of prospectively triggered vs retrospectively gated coronary computed tomography angiography: Meta-analysis of diagnostic accuracy, image quality, and radiation dose.

Jan Menke1, Christina Unterberg-Buchwald, Wieland Staab, Jan Martin Sohns, Ali Seif Amir Hosseini, Alexander Schwarz.   

Abstract

BACKGROUND: In coronary computed tomography (CT) angiography (CTA) prospective electrocardiography triggering requires less radiation dose than retrospective electrocardiography gating but provides less cardiac phases for interpretation. This meta-analysis presents a concise and comprehensive head-to-head comparison of image quality, diagnostic accuracy, and radiation dose of prospectively triggered coronary CTA vs retrospectively gated CTA in patients with suspected or known coronary artery disease (CAD).
METHODS: In patients with CAD and without tachyarrhythmia, eligible studies (selected from 4 databases) compared prospectively triggered vs retrospectively gated CTA (performed with ≥64-slice CT or dual-source CT) in 2 groups having approximately similar patient characteristics, scored CTA image quality, and/or assessed how accurately CTA diagnoses ≥50% coronary stenoses compared with catheter angiography and reported the radiation dose. The data were meta-analyzed by random-effects models, with CIs provided in the text.
RESULTS: Among 3,330 patients from 20 included studies, 91.3% of CTAs (segments: 97.8%) had diagnostic quality with prospective triggering and 93.3% of CTAs (segments: 98.4%) with retrospective gating (P > .05). Among 664 patients from 5 studies, the pooled sensitivity/specificity of diagnostic CTAs was 98.7%/91.3% (segment level: 91.3%/97.7%) with prospective triggering and 96.9%/95.8% (segment level: 93.1%/97.6%) with retrospective gating (P > .05). The pooled effective dose was 3.5 mSv with prospective triggering and thus, by a factor of 3.5, lower than the pooled effective dose of retrospective gating, which was 12.3 mSv (P < .01).
CONCLUSIONS: In patients with CAD and without tachyarrhythmia, prospectively triggered coronary CTA provides image quality and diagnostic accuracy comparable with retrospectively gated CTA, but at a much lower radiation dose.
Copyright © 2013 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23351817     DOI: 10.1016/j.ahj.2012.10.026

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  33 in total

1.  Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol.

Authors:  Moritz H Albrecht; John W Nance; U Joseph Schoepf; Brian E Jacobs; Richard R Bayer; Sheldon E Litwin; Michael A Reynolds; Katharina Otani; Stefanie Mangold; Akos Varga-Szemes; Domenico De Santis; Marwen Eid; Georg Apfaltrer; Christian Tesche; Markus Goeller; Thomas J Vogl; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2017-11-27       Impact factor: 5.315

2.  Effects of two different anesthetic protocols on 64-MDCT coronary angiography in dogs.

Authors:  Randi Drees; Rebecca A Johnson; Marie Pinkerton; Alejandro Munoz Del Rio; Jimmy H Saunders; Christopher J François
Journal:  Vet Radiol Ultrasound       Date:  2014-07-26       Impact factor: 1.363

3.  Prognostic Performance of Prospective versus Retrospective Electrocardiographic Gating in Coronary Computed Tomographic Angiography.

Authors:  Pradnya Velankar; Kongkiat Chaikriangkrai; Ninad Dewal; Sayf Khaleel Bala; Belqis Elferjani; Sama Alchalabi; Su Min Chang
Journal:  Tex Heart Inst J       Date:  2018-08-01

4.  The associated factors for radiation dose variation in cardiac CT angiography.

Authors:  Ali B Alhailiy; Ernest U Ekpo; Peter L Kench; Elaine A Ryan; Patrick C Brennan; Mark McEntee
Journal:  Br J Radiol       Date:  2019-01-31       Impact factor: 3.039

5.  Initial exploration of coronary stent image subtraction using dual-layer spectral CT.

Authors:  Le Qin; ShengJia Gu; ChiHua Chen; Huan Zhang; ZhenBin Zhu; XingBiao Chen; Qun Han; FuHua Yan; WenJie Yang
Journal:  Eur Radiol       Date:  2019-01-21       Impact factor: 5.315

Review 6.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

Review 7.  Diagnostic accuracy and utility of coronary CT angiography with consideration of unevaluable results: A systematic review and multivariate Bayesian random-effects meta-analysis with intention to diagnose.

Authors:  Jan Menke; Jörg Kowalski
Journal:  Eur Radiol       Date:  2015-05-20       Impact factor: 5.315

8.  Defining the flow-limiting stenosis noninvasively for management of patients with coronary artery disease.

Authors:  Tiago A Magalhães; João A C Lima
Journal:  JACC Cardiovasc Interv       Date:  2013-12-11       Impact factor: 11.195

Review 9.  Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments.

Authors:  Sandeep S Hedgire; Vinit Baliyan; Brian B Ghoshhajra; Mannudeep K Kalra
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-24

10.  Evaluation of an adaptive detector collimation for prospectively ECG-triggered coronary CT angiography with third-generation dual-source CT.

Authors:  Michael Messerli; Patricia Dewes; Jan-Erik Scholtz; Christophe Arendt; Simon Wildermuth; Thomas J Vogl; Ralf W Bauer
Journal:  Eur Radiol       Date:  2017-12-07       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.