Literature DB >> 30617960

Digital vs. analog PET/CT: intra-subject comparison of the SUVmax in target lesions and reference regions.

Francisco Fuentes-Ocampo1, Diego Alfonso López-Mora2, Albert Flotats2, Gabriela Paillahueque3, Valle Camacho2, Joan Duch2, Alejandro Fernández2, Anna Domènech2, Montserrat Estorch2, Ignasi Carrió2.   

Abstract

PURPOSE: The purpose of this study was to assess whether digital photon counting technology in digital PET/CT influences the quantification of SUVmax in target lesions and regions of reference compared to analog PET/CT before an interchangeable use of either system in follow up studies.
METHODS: From January to June of 2018, 100 oncological patients underwent successive PET/CT imaging with digital and analog systems in the same day. Fifty-eight patients underwent analog imaging first and digital imaging thereafter, and 42 patients the other way round. SUVmax was measured in reference regions (liver and mediastinal blood pool) and in the most metabolically active target lesion in each patient. According to the sequence order of PET/CT acquisition, two groups of SUVmax values were obtained, i.e. group 1: analog PET/CT performed first; group 2: digital PET/CT performed first.
RESULTS: Mean SUVmax in the total sample (regardless of the order of PET/CT acquisition) in the target lesions with the analog PET/CT was 8.14 ± 6.39 and the digital 9.97 ± 6.14 (P = 0.000). Total mean SUVmax in the liver with the analog was 4.39 ± 2.59 and the digital 4.46 ± 3.18 (P = 0.477). Total mean SUVmax in the mediastinal blood pool with the analog was 2.30 ± 0.67 and the digital 2.54 ± 0.74 (P = 0.000). Group 1: mean SUVmax in the target lesions with the analog system was 6.64 ± 4.71 and the digital 9.48 ± 5.60 (P = 0.000). Mean liver SUVmax with the analog was 4.70 ± 2.90 and the digital 4.80 ± 3.72 (P = 0.088). Mediastinal blood pool SUVmax with the analog was 2.33 ± 0.66 and the digital 2.45 ± 0.73 (P = 0.041). Group 2: mean SUVmax in target lesions with the digital system was 10.63 ± 6.88 and the analog 10.16 ± 7.76 (P = 0.046). Mean liver SUVmax with the digital was 3.99 ± 2.20 and the analog 3.96 ± 2.04 (P = 0.218). Mediastinal blood pool SUVmax with the digital was 2.66 ± 0.75 and the analog 2.27 ± 0.68 (P = 0.000). No significant differences between both time delays were found.
CONCLUSIONS: Improved photon counting technology in the digital PET/CT, and the effect of delayed increased uptake and retention significantly increases SUVmax values. This has to be taken into account before interchangeable use of either system in follow up studies.

Entities:  

Keywords:  Analog PET/CT; Digital PET/CT; Intra-subject comparison; SUVmax

Mesh:

Substances:

Year:  2019        PMID: 30617960     DOI: 10.1007/s00259-018-4256-0

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  17 in total

1.  18F choline PET/CT in the preoperative staging of prostate cancer in patients with intermediate or high risk of extracapsular disease: a prospective study of 130 patients.

Authors:  Mohsen Beheshti; Larisa Imamovic; Gabriele Broinger; Reza Vali; Peter Waldenberger; Franz Stoiber; Michael Nader; Bernhard Gruy; Guenter Janetschek; Werner Langsteger
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

2.  Localization of primary prostate cancer with dual-phase 18F-fluorocholine PET.

Authors:  Sandi A Kwee; Hai Wei; Isabell Sesterhenn; David Yun; Marc N Coel
Journal:  J Nucl Med       Date:  2006-02       Impact factor: 10.057

Review 3.  Application of silicon photomultipliers to positron emission tomography.

Authors:  Emilie Roncali; Simon R Cherry
Journal:  Ann Biomed Eng       Date:  2011-02-15       Impact factor: 3.934

4.  Dynamic changes of FDG uptake and clearance in normal tissues.

Authors:  Gang Cheng; Abass Alavi; Esther Lim; Thomas J Werner; Catherine V Del Bello; Scott R Akers
Journal:  Mol Imaging Biol       Date:  2013-06       Impact factor: 3.488

5.  Influence of reconstruction iterations on 18F-FDG PET/CT standardized uptake values.

Authors:  Chris J Jaskowiak; Jesus A Bianco; Scott B Perlman; Jason P Fine
Journal:  J Nucl Med       Date:  2005-03       Impact factor: 10.057

6.  Effects of noise, image resolution, and ROI definition on the accuracy of standard uptake values: a simulation study.

Authors:  Ronald Boellaard; Nanda C Krak; Otto S Hoekstra; Adriaan A Lammertsma
Journal:  J Nucl Med       Date:  2004-09       Impact factor: 10.057

7.  Increasing uptake time in FDG-PET: standardized uptake values in normal tissues at 1 versus 3 h.

Authors:  Bennett B Chin; Edward D Green; Timothy G Turkington; Thomas C Hawk; R Edward Coleman
Journal:  Mol Imaging Biol       Date:  2008-11-27       Impact factor: 3.488

Review 8.  When should we recommend use of dual time-point and delayed time-point imaging techniques in FDG PET?

Authors:  Gang Cheng; Drew A Torigian; Hongming Zhuang; Abass Alavi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-01-30       Impact factor: 9.236

9.  [18F]fluorocholine PET/CT imaging for the detection of recurrent prostate cancer at PSA relapse: experience in 100 consecutive patients.

Authors:  Marino Cimitan; Roberto Bortolus; Sandro Morassut; Vincenzo Canzonieri; Antonio Garbeglio; Tanja Baresic; Eugenio Borsatti; Annalisa Drigo; Mauro G Trovò
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-07-25       Impact factor: 10.057

10.  Dual-phase PET-CT to differentiate [18F]Fluoromethylcholine uptake in reactive and malignant lymph nodes in patients with prostate cancer.

Authors:  Daniela E Oprea-Lager; Andrew D Vincent; Reindert J A van Moorselaar; Winald R Gerritsen; Alfons J M van den Eertwegh; Jonas Eriksson; Ronald Boellaard; Otto S Hoekstra
Journal:  PLoS One       Date:  2012-10-31       Impact factor: 3.240

View more
  13 in total

1.  Digital PET/CT: a new intriguing chance for clinical nuclear medicine and personalized molecular imaging.

Authors:  Orazio Schillaci; Nicoletta Urbano
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-03-11       Impact factor: 9.236

2.  Small-voxel reconstructions significantly influence SUVs in PET imaging.

Authors:  Daniëlle Koopman; Pieter L Jager; Jorn A van Dalen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-03-13       Impact factor: 9.236

3.  Quantitative and qualitative evaluation of sequential PET/MRI using a newly developed mobile PET system for brain imaging.

Authors:  Mizue Suzuki; Yasutaka Fushimi; Tomohisa Okada; Takuya Hinoda; Ryusuke Nakamoto; Yoshiki Arakawa; Nobukatsu Sawamoto; Kaori Togashi; Yuji Nakamoto
Journal:  Jpn J Radiol       Date:  2021-02-28       Impact factor: 2.374

4.  Superior performance of 18F-fluorocholine digital PET/CT in the detection of parathyroid adenomas.

Authors:  Diego Alfonso López-Mora; Marina Sizova; Montserrat Estorch; Albert Flotats; Valle Camacho; Alejandro Fernández; Safae Abouzian; Francisco Fuentes-Ocampo; José Ignacio Pérez Garcia; Ana Isabel Chico Ballesteros; Joan Duch; Anna Domènech; Antonio Moral Duarte; Ignasi Carrió
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-01-09       Impact factor: 9.236

5.  Comparison of Image Quality and Semi-quantitative Measurements with Digital PET/CT and Standard PET/CT from Different Vendors.

Authors:  Sung Hoon Kim; Bong-Il Song; Hae Won Kim; Kyoung Sook Won
Journal:  Nucl Med Mol Imaging       Date:  2020-08-13

6.  Digital versus analogue PET in [68Ga]Ga-PSMA-11 PET/CT for recurrent prostate cancer: a matched-pair comparison.

Authors:  Ian Alberts; George Prenosil; Christos Sachpekidis; Thilo Weitzel; Kuangyu Shi; Axel Rominger; Ali Afshar-Oromieh
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-12-02       Impact factor: 9.236

7.  Monte Carlo simulation of digital photon counting PET.

Authors:  Julien Salvadori; Joey Labour; Freddy Odille; Pierre-Yves Marie; Jean-Noël Badel; Laëtitia Imbert; David Sarrut
Journal:  EJNMMI Phys       Date:  2020-04-25

8.  Digital PET/CT allows for shorter acquisition protocols or reduced radiopharmaceutical dose in [18F]-FDG PET/CT.

Authors:  Ian Alberts; Christos Sachpekidis; George Prenosil; Marco Viscione; Karl Peter Bohn; Clemens Mingels; Kuangyu Shi; Ali Ashar-Oromieh; Axel Rominger
Journal:  Ann Nucl Med       Date:  2021-02-07       Impact factor: 2.668

9.  Moving the goalposts while scoring-the dilemma posed by new PET technologies.

Authors:  Julian M M Rogasch; Ronald Boellaard; Lucy Pike; Peter Borchmann; Peter Johnson; Jürgen Wolf; Sally F Barrington; Carsten Kobe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-05-14       Impact factor: 9.236

10.  Results of a Prospective Trial to Compare 68Ga-DOTA-TATE with SiPM-Based PET/CT vs. Conventional PET/CT in Patients with Neuroendocrine Tumors.

Authors:  Lucia Baratto; Akira Toriihara; Negin Hatami; Carina M Aparici; Guido Davidzon; Craig S Levin; Andrei Iagaru
Journal:  Diagnostics (Basel)       Date:  2021-05-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.