Literature DB >> 30617486

Fetal dynamic phase-contrast MR angiography using ultrasound gating and comparison with Doppler ultrasound measurements.

B P Schoennagel1, J Yamamura2, F Kording2, R Fischer2,3, P Bannas2, G Adam2, H Kooijman4, C Ruprecht2, K Fehrs2, M Tavares de Sousa5.   

Abstract

OBJECTIVES: To investigate the feasibility of fetal phase-contrast (PC)-MR angiography of the descending aorta (AoD) using an MR-compatible Doppler ultrasound sensor (DUS) for fetal cardiac gating and to compare velocimetry with Doppler ultrasound measurements.
METHODS: In this prospective study, 2D PC-MR angiography was performed in 12 human fetuses (mean gestational age 32.8 weeks) using an MR-compatible DUS for gating of the fetal heart at 1.5 T. Peak flow velocities in the fetal AoD were compared with Doppler ultrasound measurements performed on the same day. Reproducibility of PC-MR measurements was tested by repeated PC-MR in five fetuses.
RESULTS: Dynamic PC-MR angiography in the AoD was successfully performed in all fetuses using the DUS, with an average fetal heart rate of 140 bpm (range 129-163). Time-velocity curves revealed typical arterial blood flow patterns. PC-MR mean flow velocity and mean flux were 21.2 cm/s (range 8.6-36.8) and 8.4 ml/s (range 3.2-14.6), respectively. A positive association between PC-MR mean flux and stroke volume with gestational age was obtained (r = 0.66, p = 0.02 and r = 0.63, p = 0.03). PC-MR and Doppler ultrasound peak velocities revealed a highly significant correlation (r = 0.8, p < 0.002). Peak velocities were lower for PC-MR with 69.1 cm/s (range 39-125) compared with 96.7 cm/s (range 60-142) for Doppler ultrasound (p < 0.001). Reproducibility of PC-MR was high (p > 0.05).
CONCLUSION: The MR-compatible DUS for fetal cardiac gating allows for PC-MR angiography in the fetal AoD. Comparison with Doppler ultrasound revealed a highly significant correlation of peak velocities with underestimation of PC-MR velocities. This new technique for direct fetal cardiac gating indicates the potential of PC-MR angiography for assessing fetal hemodynamics. KEY POINTS: • The developed MR-compatible Doppler ultrasound sensor allows direct fetal cardiac gating and can be used for prenatal dynamic cardiovascular MRI. • The MR-compatible Doppler ultrasound sensor was successfully applied to perform intrauterine phase-contrast MR angiography of the fetal aorta, which revealed a highly significant correlation with Doppler ultrasound measurements. • As fetal flow hemodynamics is an important parameter in the diagnosis and management of fetal pathologies, fetal phase-contrast MR angiography may offer an alternative imaging method in addition to Doppler ultrasound and develop as a second line tool in the evaluation of fetal flow hemodynamics.

Entities:  

Keywords:  Blood flow velocity; Fetal research; Magnetic resonance angiography; Ultrasonography, Doppler

Mesh:

Year:  2019        PMID: 30617486     DOI: 10.1007/s00330-018-5940-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  41 in total

1.  The application of color power angiography to the longitudinal quantification of blood flow volume in the fetal middle cerebral arteries, ascending aorta, descending aorta, and renal arteries during gestation.

Authors:  J C Konje; K Abrams; S C Bell; R C de Chazal; D J Taylor
Journal:  Am J Obstet Gynecol       Date:  2000-02       Impact factor: 8.661

Review 2.  Blood flow measurement by magnetic resonance imaging in congenital heart disease.

Authors:  A J Powell; T Geva
Journal:  Pediatr Cardiol       Date:  2000 Jan-Feb       Impact factor: 1.655

3.  Quantification of blood flow in the carotid arteries: comparison of Doppler ultrasound and three different phase-contrast magnetic resonance imaging sequences.

Authors:  J Seitz; M Strotzer; T Wild; W R Nitz; M Völk; M Lenhart; S Feuerbach
Journal:  Invest Radiol       Date:  2001-11       Impact factor: 6.016

4.  Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation.

Authors:  Joachim Lotz; Christian Meier; Andreas Leppert; Michael Galanski
Journal:  Radiographics       Date:  2002 May-Jun       Impact factor: 5.333

5.  Color and conventional image-directed Doppler ultrasonography: accuracy and sources of error in quantitative blood flow measurements.

Authors:  C Ranke; P Hendrickx; U Roth; F Brassel; A Creutzig; K Alexander
Journal:  J Clin Ultrasound       Date:  1992 Mar-Apr       Impact factor: 0.910

6.  Real-time Fourier velocity encoding: an in vivo evaluation.

Authors:  Christopher K Macgowan; Christian J Kellenberger; Jay S Detsky; Kevin Roman; Shi-Joon Yoo
Journal:  J Magn Reson Imaging       Date:  2005-03       Impact factor: 4.813

7.  Brain hydrodynamics study by phase-contrast magnetic resonance imaging and transcranial color doppler.

Authors:  Olivier Balédent; Loïc Fin; Louis Khuoy; Khalid Ambarki; Anne-Cécile Gauvin; Catherine Gondry-Jouet; Marc-Etienne Meyer
Journal:  J Magn Reson Imaging       Date:  2006-11       Impact factor: 4.813

8.  New and improved Israeli reference of birth weight, birth length, and head circumference by gestational age: a hospital-based study.

Authors:  Shmuel Davidson; Nir Sokolover; Avi Erlich; Aviva Litwin; Nehama Linder; Lea Sirota
Journal:  Isr Med Assoc J       Date:  2008-02       Impact factor: 0.892

9.  Assessment of coronary flow reserve with fast cine phase contrast magnetic resonance imaging: comparison with measurement by Doppler guide wire.

Authors:  M Shibata; H Sakuma; N Isaka; K Takeda; C B Higgins; T Nakano
Journal:  J Magn Reson Imaging       Date:  1999-10       Impact factor: 4.813

10.  The impact of maternal obesity on midtrimester sonographic visualization of fetal cardiac and craniospinal structures.

Authors:  I Hendler; S C Blackwell; E Bujold; M C Treadwell; H M Wolfe; R J Sokol; Y Sorokin
Journal:  Int J Obes Relat Metab Disord       Date:  2004-12
View more
  5 in total

1.  Fetal Physiologically Based Pharmacokinetic Models: Systems Information on Fetal Cardiac Output and Its Distribution to Different Organs during Development.

Authors:  Khaled Abduljalil; Xian Pan; Ruth Clayton; Trevor N Johnson; Masoud Jamei
Journal:  Clin Pharmacokinet       Date:  2021-01-24       Impact factor: 6.447

Review 2.  Fetal Cardiac MRI: A Review of Technical Advancements.

Authors:  Christopher W Roy; Joshua F P van Amerom; Davide Marini; Mike Seed; Christopher K Macgowan
Journal:  Top Magn Reson Imaging       Date:  2019-10

3.  Doppler ultrasound cardiac gating of intracranial flow at 7T.

Authors:  Karin Markenroth Bloch; Fabian Kording; Johannes Töger
Journal:  BMC Med Imaging       Date:  2020-12-09       Impact factor: 1.930

Review 4.  Inorganic Nanomaterial for Biomedical Imaging of Brain Diseases.

Authors:  Wenxian Du; Lingling Zhou; Qiang Zhang; Xin Liu; Xiaoer Wei; Yuehua Li
Journal:  Molecules       Date:  2021-12-03       Impact factor: 4.411

5.  Fetal whole heart blood flow imaging using 4D cine MRI.

Authors:  Thomas A Roberts; Joshua F P van Amerom; Alena Uus; David F A Lloyd; Milou P M van Poppel; Anthony N Price; Jacques-Donald Tournier; Chloe A Mohanadass; Laurence H Jackson; Shaihan J Malik; Kuberan Pushparajah; Mary A Rutherford; Reza Razavi; Maria Deprez; Joseph V Hajnal
Journal:  Nat Commun       Date:  2020-10-05       Impact factor: 14.919

  5 in total