Real-time Fourier velocity encoding: an in vivo evaluation.

Christopher K Macgowan1, Christian J Kellenberger, Jay S Detsky, Kevin Roman, Shi-Joon Yoo.   

Abstract

PURPOSE: To compare in vivo real-time Fourier velocity encoding (FVE), spectral-Doppler ultrasound, and phase-contrast (PC) magnetic-resonance (MR) imaging.
MATERIALS AND METHODS: In vivo velocity spectra were measured in the suprarenal and infrarenal aorta and the hepatic segment of the inferior vena cava of eight normal volunteers using FVE, and compared to similar measurements using Doppler ultrasound and gated PC MR imaging. In vivo waveforms were compared qualitatively according to flow pattern appearance (number, shape, and position of velocity peaks) and quantitatively according to peak velocity.
RESULTS: Good agreement was obtained between peak velocities measured in vitro using FVE and PC MR imaging (R(2) = 0.99, P = 2.10(-6), slope = 0.97 +/- 0.05). Qualitatively, the FVE and ultrasound measurements agreed closely in the majority of in vivo cases (excellent or good in 21/24 cases) while the PC MR method resolved fewer velocity peaks due to the inherent temporal averaging of cardiac-gated studies (excellent or good agreement with FVE in 13/24 cases). Quantitatively, the FVE measurement of peak velocity correlated strongly with both ultrasound (R(2) = 0.71, P = 2.10(-7), slope = 0.81 +/- 0.08) and PC MR (R(2) = 0.85, P = 2.10(-10), slope = 1.04 +/- 0.08).
CONCLUSION: Real-time MR assessment of blood-flow velocity correlated well with spectral Doppler ultrasound. Such new methods may allow hemodynamic information to be acquired in vessels inaccessible to ultrasound or in patients for whom respiratory compensation is not possible. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 15723365     DOI: 10.1002/jmri.20266

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Integrated physiological flow simulator and pulse sequence monitoring system for MRI.

Authors:  Pauline Wong; Martin J Graves; David J Lomas
Journal:  Med Biol Eng Comput       Date:  2008-02-22       Impact factor: 2.602

2.  Fetal dynamic phase-contrast MR angiography using ultrasound gating and comparison with Doppler ultrasound measurements.

Authors:  B P Schoennagel; J Yamamura; F Kording; R Fischer; P Bannas; G Adam; H Kooijman; C Ruprecht; K Fehrs; M Tavares de Sousa
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

Review 3.  4D flow imaging: current status to future clinical applications.

Authors:  Michael Markl; Susanne Schnell; Alex J Barker
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

4.  Reducing artifacts in one-dimensional Fourier velocity encoding for fast and pulsatile flow.

Authors:  Daeho Lee; Juan M Santos; Bob S Hu; John M Pauly; Adam B Kerr
Journal:  Magn Reson Med       Date:  2012-03-27       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.