BACKGROUND: To evaluate the detection rate and image quality in CT-body-packer-screening at different radiation-dose levels and to determine a dose threshold that enables a reliable detection of incorporated body packs and incidental findings with a maximum of dose saving.Entities:
Keywords: CT dose; Drug abuse; Image analysis; Low dose CT
Mesh:
Substances:
Year: 2018 PMID: 30526681 PMCID: PMC6284291 DOI: 10.1186/s40001-018-0356-3
Source DB: PubMed Journal: Eur J Med Res ISSN: 0949-2321 Impact factor: 2.175
The overall estimated dose results (CTDIvol, DLP, and effective dose), due to dose level at 100% and the estimated dose savings at 50%, 10, 5%, and 1% of initial dose
| CTDIvol (mGy) mean ± SD | DLP (mGycm) mean ± SD | Eff. dose (mSv) mean ± SD | |
|---|---|---|---|
| Full dose (%) | |||
| 100 | 2.96 ± 1.83 | 140 ± 88.1 | 2.10 ± 1.32 |
| Estimated dose savings (%) | |||
| 50 | 1.05 ± 0.66 | ||
| 10 | 0.21 ± 0.13 | ||
| 5 | 0.11 ± 0.07 | ||
| 1 | 0.02 ± 0.01 | ||
Fig. 1A 22-year-old body packer, who was examined with 80 kVp and automated tube current modulation (tube current time product: 88 mAs, effective dose at 100%: 1.16 mSv). The axial reconstructions (soft tissue window, window level 40/300) with stepwise reduced dose levels (100%, 50%, 10%, 5%, and 1%) show multiple liquid body packets (white arrows) which are hyperattenuating compared to the surrounding bowel content. While differentiation of bowel and that of urinary bladder decrease within stepwise dose reduction, liquid cocaine remains easily detectable with only 1% of initial radiation dose (effective dose: 0.01 mSv)
Fig. 2A 58-year-old individual suspected of body packing. CT examination was performed at 80 kVp with ATCM (tube current time product: 81 mAs, dose level 100% effective dose at 100%: 1.09 mSv). Axial CT scans (soft tissue window, window level 40/300) with stepwise dose reduction (100%, 50%, 10%, 5%, and 1%). In this case at 1% of initial dose (0.02 mSv), one additional false-positive solid body packet was rated by reader one (white arrow)
Fig. 3A 40-year-old body packer, who was examined with 80 kVp and automated tube current modulation (tube current time product: 134 mAs, effective dose at 100%: 1.97 mSv). The axial reconstructions (soft tissue window, window level 40/300) with stepwise dose reduction (100%, 50%, 10%, 5%, and 1%) show multiple solid body packets (white curved arrows), which remained easily detectable at only 1% of initial dose (0.02 mSv). The liver cyst (white arrows) was missed by all readers at dose level 5% and 1%