Literature DB >> 30523455

Visualization of carotid vessel wall and atherosclerotic plaque: T1-SPACE vs. compressed sensing T1-SPACE.

Sachi Okuchi1, Yasutaka Fushimi2, Tomohisa Okada3, Akira Yamamoto1, Tsutomu Okada1, Takayuki Kikuchi4, Kazumichi Yoshida4, Susumu Miyamoto4, Kaori Togashi1.   

Abstract

OBJECTIVES: To compare visualization of carotid plaques and vessel walls between 3D T1-fast spin echo imaging with conventional SPACE (T1-SPACE) and with a prototype compressed sensing T1-SPACE (CS-T1-SPACE)
METHODS: This retrospective study was approved by the institutional review board. Participants comprised 43 patients (36 males, 7 females; mean age, 71 years) who underwent carotid MRI including T1-SPACE and CS-T1-SPACE. The quality of visualization for carotid plaques and vessel walls was evaluated using a 5-point scale, and signal intensity ratios (SRs) of the carotid plaques were measured and normalized to the adjacent sternomastoid muscle. Scores for the quality of visualization were compared between T1-SPACE and CS-T1-SPACE using the Wilcoxon signed-rank test. Statistical differences between SRs of plaques with T1-SPACE and CS-T1-SPACE were also evaluated using the Wilcoxon signed-rank test, and Spearman's correlation coefficient was calculated to investigate correlations.
RESULTS: Visualization scores were significantly higher for CS-T1-SPACE than for T1-SPACE when evaluating carotid plaques (p = 0.0212) and vessel walls (p < 0.001). The SR of plaques did not differ significantly between T1-SPACE and CS-T1-SPACE (p = 0.5971). Spearman's correlation coefficient was significant (0.884; p < 0.0001).
CONCLUSIONS: CS-T1-SPACE allowed better visualization scores and sharpness compared with T1-SPACE in evaluating carotid plaques and vessel walls, with a 2.5-fold accelerated scan time with comparable image quality. CS-T1-SPACE appears promising as a method for investigating carotid vessel walls, offering better image quality with a shorter acquisition time. KEY POINTS: • CS-T1-SPACE allowed better visualization compared with T1-SPACE in evaluating carotid plaques and vessel walls, with a 2.5-fold accelerated scan time with comparable image quality. • CS-T1-SPACE offers a promising method for investigating carotid vessel walls due to the better image quality with shorter acquisition time. • Physiological movements such as swallowing, arterial pulsations, and breathing induce motion artifacts in vessel wall imaging, and a shorter acquisition time can reduce artifacts from physiological movements.

Entities:  

Keywords:  Artifacts; Atherosclerosis; Carotid stenosis; Image reconstruction; Magnetic resonance imaging

Mesh:

Year:  2018        PMID: 30523455     DOI: 10.1007/s00330-018-5862-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  26 in total

1.  Advances in sensitivity encoding with arbitrary k-space trajectories.

Authors:  K P Pruessmann; M Weiger; P Börnert; P Boesiger
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Carotid intraplaque hemorrhage predicts recurrent symptoms in patients with high-grade carotid stenosis.

Authors:  Nishath Altaf; Shane T MacSweeney; John Gladman; Dorothee P Auer
Journal:  Stroke       Date:  2007-03-22       Impact factor: 7.914

4.  Sparse MRI: The application of compressed sensing for rapid MR imaging.

Authors:  Michael Lustig; David Donoho; John M Pauly
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

5.  Whole-heart imaging using undersampled radial phase encoding (RPE) and iterative sensitivity encoding (SENSE) reconstruction.

Authors:  R Boubertakh; C Prieto; P G Batchelor; S Uribe; D Atkinson; H Eggers; T S Sørensen; M S Hansen; R S Razavi; T Schaeffter
Journal:  Magn Reson Med       Date:  2009-11       Impact factor: 4.668

6.  Accelerating SENSE using compressed sensing.

Authors:  Dong Liang; Bo Liu; Jiunjie Wang; Leslie Ying
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

7.  Accelerated 3D MERGE carotid imaging using compressed sensing with a hidden Markov tree model.

Authors:  Mahender K Makhijani; Niranjan Balu; Kiyofumi Yamada; Chun Yuan; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2012-07-23       Impact factor: 4.813

8.  Incidence and risk factors of silent brain infarcts in the population-based Rotterdam Scan Study.

Authors:  Sarah E Vermeer; Tom Den Heijer; Peter J Koudstaal; Matthijs Oudkerk; Albert Hofman; Monique M B Breteler
Journal:  Stroke       Date:  2003-02       Impact factor: 7.914

9.  Dynamic and static magnetic resonance angiography of the supra-aortic vessels at 3.0 T: intraindividual comparison of gadobutrol, gadobenate dimeglumine, and gadoterate meglumine at equimolar dose.

Authors:  Jens Harald Kramer; Elisabeth Arnoldi; Christopher J François; Andrew L Wentland; Konstantin Nikolaou; Bernd J Wintersperger; Thomas M Grist
Journal:  Invest Radiol       Date:  2013-03       Impact factor: 6.016

10.  Swallowing, arterial pulsation, and breathing induce motion artifacts in carotid artery MRI.

Authors:  Loic Boussel; Gwenael Herigault; Alejandro de la Vega; Michel Nonent; Philippe Charles Douek; Jean Michel Serfaty
Journal:  J Magn Reson Imaging       Date:  2006-03       Impact factor: 4.813

View more
  7 in total

1.  Compressed sensing MRI of different organs: ready for clinical daily practice?

Authors:  Bénédicte Marie Anne Delattre; Sana Boudabbous; Catrina Hansen; Angeliki Neroladaki; Anne-Lise Hachulla; Maria Isabel Vargas
Journal:  Eur Radiol       Date:  2019-07-01       Impact factor: 5.315

2.  Evaluation of cerebral arteriovenous shunts: a comparison of parallel imaging time-of-flight magnetic resonance angiography (TOF-MRA) and compressed sensing TOF-MRA to digital subtraction angiography.

Authors:  Akihiko Sakata; Yasutaka Fushimi; Tomohisa Okada; Satoshi Nakajima; Takuya Hinoda; Peter Speier; Michaela Schmidt; Christoph Forman; Kazumichi Yoshida; Hiroharu Kataoka; Susumu Miyamoto; Yuji Nakamoto
Journal:  Neuroradiology       Date:  2020-10-15       Impact factor: 2.804

3.  Joint intracranial and carotid vessel wall imaging in 5 minutes using compressed sensing accelerated DANTE-SPACE.

Authors:  Sen Jia; Lei Zhang; Lijie Ren; Yulong Qi; Jinhao Ly; Na Zhang; Ye Li; Xin Liu; Hairong Zheng; Dong Liang; Yiu-Cho Chung
Journal:  Eur Radiol       Date:  2019-08-01       Impact factor: 5.315

4.  Application of 3D T1-SPACE combined with 3D-TOF sequence for follow-up evaluation of stent-assisted coil embolization for intracranial aneurysm.

Authors:  Qiuji Shao; Qiang Li; Qiaowei Wu; Tianxiao Li; Li Li; Kaitao Chang; Yingkun He
Journal:  J Interv Med       Date:  2021-02-27

Review 5.  Vessel wall MR imaging in neuroradiology.

Authors:  Yasutaka Fushimi; Kazumichi Yoshida; Masakazu Okawa; Takakuni Maki; Satoshi Nakajima; Akihiko Sakata; Sachi Okuchi; Takuya Hinoda; Mitsunori Kanagaki; Yuji Nakamoto
Journal:  Radiol Med       Date:  2022-07-30       Impact factor: 6.313

6.  Evaluation of 3D multi-contrast carotid vessel wall MRI: a comparative study.

Authors:  Hanyu Wei; Miaoqi Zhang; Yunduo Li; Xihai Zhao; Gador Canton; Jie Sun; Dongxiang Xu; Zechen Zhou; Shuo Chen; Marina S Ferguson; Thomas S Hatsukami; Rui Li; Chun Yuan
Journal:  Quant Imaging Med Surg       Date:  2020-01

7.  Dark blood cardiovascular magnetic resonance of the heart, great vessels, and lungs using electrocardiographic-gated three-dimensional unbalanced steady-state free precession.

Authors:  Robert R Edelman; Nondas Leloudas; Jianing Pang; Ioannis Koktzoglou
Journal:  J Cardiovasc Magn Reson       Date:  2021-11-01       Impact factor: 5.364

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.