Literature DB >> 23211552

Dynamic and static magnetic resonance angiography of the supra-aortic vessels at 3.0 T: intraindividual comparison of gadobutrol, gadobenate dimeglumine, and gadoterate meglumine at equimolar dose.

Jens Harald Kramer1, Elisabeth Arnoldi, Christopher J François, Andrew L Wentland, Konstantin Nikolaou, Bernd J Wintersperger, Thomas M Grist.   

Abstract

PURPOSE: The purpose of this study was the intraindividual comparison of a 1.0 M and two 0.5 M gadolinium-based contrast agents (GBCA) using equimolar dosing in dynamic and static magnetic resonance angiography (MRA) of the supra-aortic vessels.
MATERIALS AND METHODS: In this institutional review board-approved study, a total of 20 healthy volunteers (mean ± SD age, 29 ± 6 years) underwent 3 consecutive supra-aortic MRA examinations on a 3.0 T magnetic resonance system. The order of GBCA (Gadobutrol, Gadobenate dimeglumine, and Gadoterate meglumine) was randomized with a minimum interval of 48 hours between the examinations. Before each examination and 45 minutes after each examination, circulatory parameters were recorded. Total GBCA dose per MRA examination was 0.1 mmol/kg with a 0.03 mmol/kg and 0.07 mmol/kg split for dynamic and static MRA, respectively, injected at a rate of 2 mL/s. Two blinded readers qualitatively assessed static MRA data sets independently using pairwise rankings (superior, inferior, and equal). In addition, quantitative analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) evaluation as well as vessel sharpness analysis of static MRA using an in-house-developed semiautomated tool. Dynamic MRA was evaluated for maximal SNR. Statistical analysis was performed using the Cohen κ, the Wilcoxon rank sum tests, and mixed effects models.
RESULTS: No significant differences of hemodynamic parameters were observed. In static MRA, Gadobutrol was rated superior to Gadoterate meglumine (P < 0.05) and equal to Gadobenate dimeglumine (P = 0.06) with good to excellent reader agreement (κ, 0.66-0.83). In static MRA, SNR was significantly higher using 1.0 M Gadobutrol as compared with either 0.5 M agent (P < 0.05 and P < 0.05) and CNR was significantly higher as compared with Gadoterate meglumine (P < 0.05), whereas CNR values of Gadobutrol data sets were not significantly different as compared with Gadobenate dimeglumine (P = 0.13). Differences in CNR between Gadobenate dimeglumine and Gadoterate meglumine were not significant (P = 0.78). Differences in vessel sharpness between the different GBCAs were also not significant (P > 0.05). Maximal SNR in dynamic MRA using Gadobutrol was significantly higher than both comparators at the level of the proximal and distal internal carotid artery (P < 0.05 and P < 0.05; P < 0.05 and P < 0.05).
CONCLUSIONS: At equimolar doses, 1.0 M Gadobutrol demonstrates higher SNR/CNR than do Gadobenate dimeglumine and Gadoterate meglumine, with superior image quality as compared with Gadoterate meglumine for dynamic and static carotid MRA. Despite the shortened bolus with Gadobutrol, no blurring of vessel edges was observed.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23211552      PMCID: PMC3818529          DOI: 10.1097/RLI.0b013e31827752b4

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  35 in total

1.  Safety and effectiveness of single- versus triple-dose gadodiamide injection- enhanced MR angiography of the abdomen: a phase III double-blind multicenter study.

Authors:  S A Thurnher; A Capelastegui; F H Del Olmo; R F Dondelinger; C Gervás; A G Jassoy; P Keto; C Loewe; C N Ludman; L Marti-Bonmati; M Meusel; J P da Cruz; J P Pruvo; V M Sanjuan; T Vogl
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

2.  Carotid artery stenosis: contrast-enhanced MR angiography with two different scan times compared with digital subtraction angiography.

Authors:  P C Sundgren; P Sundén; A Lindgren; J Lanke; S Holtås; E-M Larsson
Journal:  Neuroradiology       Date:  2002-06-20       Impact factor: 2.804

3.  Thorax: low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution--initial results.

Authors:  J Paul Finn; Visveshwar Baskaran; James C Carr; Richard M McCarthy; F Scott Pereles; Randall Kroeker; Gerhard A Laub
Journal:  Radiology       Date:  2002-09       Impact factor: 11.105

4.  Cardiovascular disease in non-Western countries.

Authors:  K Srinath Reddy
Journal:  N Engl J Med       Date:  2004-06-10       Impact factor: 91.245

5.  How to compare the efficiency of albumin-bound and nonalbumin-bound contrast agents in vivo: the concept of dynamic relaxivity.

Authors:  Marc Port; Claire Corot; Xavier Violas; Philippe Robert; Isabelle Raynal; Georgia Gagneur
Journal:  Invest Radiol       Date:  2005-09       Impact factor: 6.016

6.  Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths.

Authors:  Martin Rohrer; Hans Bauer; Jan Mintorovitch; Martin Requardt; Hanns-Joachim Weinmann
Journal:  Invest Radiol       Date:  2005-11       Impact factor: 6.016

Review 7.  Emerging epidemic of cardiovascular disease in developing countries.

Authors:  K S Reddy; S Yusuf
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

8.  Does higher gadolinium concentration play a role in the morphologic assessment of brain tumors? Results of a multicenter intraindividual crossover comparison of gadobutrol versus gadobenate dimeglumine (the MERIT Study).

Authors:  Z Seidl; J Vymazal; M Mechl; M Goyal; M Herman; C Colosimo; M Pasowicz; R Yeung; B Paraniak-Gieszczyk; B Yemen; N Anzalone; A Citterio; G Schneider; S Bastianello; J Ruscalleda
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-01       Impact factor: 3.825

9.  Carotid artery stenosis: intraindividual correlations of 3D time-of-flight MR angiography, contrast-enhanced MR angiography, conventional DSA, and rotational angiography for detection and grading.

Authors:  Nicoletta Anzalone; Francesco Scomazzoni; Renata Castellano; Laura Strada; Claudio Righi; Letterio S Politi; Miles A Kirchin; Roberto Chiesa; Giuseppe Scotti
Journal:  Radiology       Date:  2005-06-13       Impact factor: 11.105

10.  Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla.

Authors:  Jörg Pintaske; Petros Martirosian; Hansjörg Graf; Gunter Erb; Klaus-Peter Lodemann; Claus D Claussen; Fritz Schick
Journal:  Invest Radiol       Date:  2006-03       Impact factor: 6.016

View more
  12 in total

Review 1.  Gadolinium contrast agents for CNS imaging: current concepts and clinical evidence.

Authors:  E Kanal; K Maravilla; H A Rowley
Journal:  AJNR Am J Neuroradiol       Date:  2014-05-22       Impact factor: 3.825

Review 2.  Gadobutrol: a review of its use for contrast-enhanced magnetic resonance imaging in adults and children.

Authors:  Lesley J Scott
Journal:  Clin Drug Investig       Date:  2013-04       Impact factor: 2.859

3.  Dynamic contrast-enhanced MR imaging of the prostate: intraindividual comparison of gadoterate meglumine and gadobutrol.

Authors:  Chau Hung Lee; Balamurugan Vellayappan; Matthias Taupitz; Bernd Hamm; Patrick Asbach
Journal:  Eur Radiol       Date:  2019-07-01       Impact factor: 5.315

4.  Prospective intraindividual comparison of gadoterate and gadobutrol for cervical and intracranial contrast-enhanced magnetic resonance angiography.

Authors:  Philip Hoelter; Stefan Lang; Marina Weibart; Manuel Schmidt; Michael F X Knott; Tobias Engelhorn; Marco Essig; Stephan Kloska; Arnd Doerfler
Journal:  Neuroradiology       Date:  2017-09-14       Impact factor: 2.804

5.  Comparison of the Relaxivities of Macrocyclic Gadolinium-Based Contrast Agents in Human Plasma at 1.5, 3, and 7 T, and Blood at 3 T.

Authors:  Pavol Szomolanyi; Martin Rohrer; Thomas Frenzel; Iris M Noebauer-Huhmann; Gregor Jost; Jan Endrikat; Siegfried Trattnig; Hubertus Pietsch
Journal:  Invest Radiol       Date:  2019-09       Impact factor: 6.016

6.  Visualization of carotid vessel wall and atherosclerotic plaque: T1-SPACE vs. compressed sensing T1-SPACE.

Authors:  Sachi Okuchi; Yasutaka Fushimi; Tomohisa Okada; Akira Yamamoto; Tsutomu Okada; Takayuki Kikuchi; Kazumichi Yoshida; Susumu Miyamoto; Kaori Togashi
Journal:  Eur Radiol       Date:  2018-12-06       Impact factor: 5.315

7.  Ferumoxytol-enhanced ultrashort TE MRA and quantitative morphometry of the human kidney vasculature.

Authors:  Liam Timms; Tianyi Zhou; Yue Lyu; Ju Qiao; Vishala Mishra; Rita Maria Lahoud; Gayatri Veeramani Jayaraman; Andrew S Allegretti; David Drew; Ravi T Seethamraju; Mukesh Harisinghani; Srinivas Sridhar
Journal:  Abdom Radiol (NY)       Date:  2021-03-05

8.  Positive contrast high-resolution 3D-cine imaging of the cardiovascular system in small animals using a UTE sequence and iron nanoparticles at 4.7, 7 and 9.4 T.

Authors:  Aurélien J Trotier; William Lefrançois; Kris Van Renterghem; Jean-Michel Franconi; Eric Thiaudière; Sylvain Miraux
Journal:  J Cardiovasc Magn Reson       Date:  2015-07-07       Impact factor: 5.364

Review 9.  Gadobutrol in India-A Comprehensive Review of Safety and Efficacy.

Authors:  Jan Endrikat; Nicoletta Anzalone
Journal:  Magn Reson Insights       Date:  2017-09-11

10.  Prostate Cancer Detection with Multiparametric MRI: A Comparison of 1 M-Concentration Gadobutrol with 0.5 M-Concentration Gadolinium-Based Contrast Agents.

Authors:  Takeshi Hara; Takeshi Ogata; Hiroko Wada; Takayuki Yabuki; Susumu Kanazawa
Journal:  Curr Urol       Date:  2018-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.