Literature DB >> 11590639

Advances in sensitivity encoding with arbitrary k-space trajectories.

K P Pruessmann1, M Weiger, P Börnert, P Boesiger.   

Abstract

New, efficient reconstruction procedures are proposed for sensitivity encoding (SENSE) with arbitrary k-space trajectories. The presented methods combine gridding principles with so-called conjugate-gradient iteration. In this fashion, the bulk of the work of reconstruction can be performed by fast Fourier transform (FFT), reducing the complexity of data processing to the same order of magnitude as in conventional gridding reconstruction. Using the proposed method, SENSE becomes practical with nonstandard k-space trajectories, enabling considerable scan time reduction with respect to mere gradient encoding. This is illustrated by imaging simulations with spiral, radial, and random k-space patterns. Simulations were also used for investigating the convergence behavior of the proposed algorithm and its dependence on the factor by which gradient encoding is reduced. The in vivo feasibility of non-Cartesian SENSE imaging with iterative reconstruction is demonstrated by examples of brain and cardiac imaging using spiral trajectories. In brain imaging with six receiver coils, the number of spiral interleaves was reduced by factors ranging from 2 to 6. In cardiac real-time imaging with four coils, spiral SENSE permitted reducing the scan time per image from 112 ms to 56 ms, thus doubling the frame-rate. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11590639     DOI: 10.1002/mrm.1241

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  323 in total

1.  POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.

Authors:  Mei-Lan Chu; Hing-Chiu Chang; Hsiao-Wen Chung; Trong-Kha Truong; Mustafa R Bashir; Nan-kuei Chen
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

2.  Reconstruction of dynamic image series from undersampled MRI data using data-driven model consistency condition (MOCCO).

Authors:  Julia V Velikina; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2014-11-14       Impact factor: 4.668

3.  Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI.

Authors:  Ricardo Otazo; Daniel Kim; Leon Axel; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

4.  Low rank alternating direction method of multipliers reconstruction for MR fingerprinting.

Authors:  Jakob Assländer; Martijn A Cloos; Florian Knoll; Daniel K Sodickson; Jürgen Hennig; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

5.  Reason's Enemy Is Not Emotion: Engagement of Cognitive Control Networks Explains Biases in Gain/Loss Framing.

Authors:  Rosa Li; David V Smith; John A Clithero; Vinod Venkatraman; R McKell Carter; Scott A Huettel
Journal:  J Neurosci       Date:  2017-03-06       Impact factor: 6.167

6.  TURBINE-MRE: A 3D hybrid radial-Cartesian EPI acquisition for MR elastography.

Authors:  Yi Sui; Arvin Arani; Joshua D Trzasko; Matthew C Murphy; Phillip J Rossman; Kevin J Glaser; Kiaran P McGee; Armando Manduca; Richard L Ehman; Philip A Araoz; John Huston
Journal:  Magn Reson Med       Date:  2020-08-01       Impact factor: 4.668

7.  Self-gated MRI of multiple beat morphologies in the presence of arrhythmias.

Authors:  Francisco Contijoch; Srikant Kamesh Iyer; James J Pilla; Paul Yushkevich; Joseph H Gorman; Robert C Gorman; Harold Litt; Yuchi Han; Walter R T Witschey
Journal:  Magn Reson Med       Date:  2016-08-31       Impact factor: 4.668

8.  A GRAPPA algorithm for arbitrary 2D/3D non-Cartesian sampling trajectories with rapid calibration.

Authors:  Tianrui Luo; Douglas C Noll; Jeffrey A Fessler; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2019-05-03       Impact factor: 4.668

9.  Reducing contrast contamination in radial turbo-spin-echo acquisitions by combining a narrow-band KWIC filter with parallel imaging.

Authors:  Daniel Neumann; Felix A Breuer; Michael Völker; Tobias Brandt; Mark A Griswold; Peter M Jakob; Martin Blaimer
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

10.  Accelerated whole-heart coronary MRA using motion-corrected sensitivity encoding with three-dimensional projection reconstruction.

Authors:  Jianing Pang; Behzad Sharif; Reza Arsanjani; Xiaoming Bi; Zhaoyang Fan; Qi Yang; Kuncheng Li; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.