| Literature DB >> 30518315 |
Yuzhi Gao1, Qiang Li1, Chunshuang Wu1, Shaoyun Liu1, Mao Zhang2.
Abstract
BACKGROUND: In cases showing cerebrospinal fluid (CSF) redistribution as a compensatory mechanism in acute intracranial hypertension, the optic nerve sheath diameter (ONSD) can be used to estimate intracranial pressure (ICP). However, it remains unclear whether the ONSD can be applied in patients with skull defects after a craniectomy, because the primary injury or surgical craniectomy may alter the dynamics of the CSF circulation or structure of the optical nerve sheath. This study explored the value of the ONSD in patients after a hemicraniectomy.Entities:
Keywords: Hemicraniectomy; Intracranial pressure; Neurological outcome; Optical nerve sheath diameter
Mesh:
Year: 2018 PMID: 30518315 PMCID: PMC6280512 DOI: 10.1186/s12883-018-1202-5
Source DB: PubMed Journal: BMC Neurol ISSN: 1471-2377 Impact factor: 2.474
Fig. 1Illustration of ONSD performance and B-mode image of ONSD measurement. A linear high frequency probe placed on the closed eye in transverse visual axis plane, and then adjusted the depth and angle of ultrasound to show the image of ONSD clearly, measure the width of ONSD at 3 mm behind the globe. ONSD optical nerve sheath diameter
Fig. 2Flowchart of the included patients. ICP intracranial pressure; ONSD optical nerve sheath diameter; GOS Glasgow outcome score
Baseline characteristics
| Neurological outcome (6 months) | ||||
|---|---|---|---|---|
| All | Unfavorable GOS 1–3 | Favorable GOS4–5 | ||
| Number of patients | 33 | 20 (60.6%) | 13 (39.4%) | – |
| Age, y | 46.6 ± 14.9 | 47.9 ± 15.0 | 46.5 ± 14.1 | 0.552 |
| Sex (male), n (%) | 25 (75.8%) | 15 (45.5%) | 10 (30.3%) | 0.619 |
| Causes of surgery, n (%) | 0.474 | |||
| Traumatic brain injury | 31 (93.9%) | 14 (42.4%) | 17 (51.5%) | – |
| Hemorrhage stroke | 2 (6.1%) | 2 (6.1%) | 0 | – |
| Initial Glasgow coma score (GCS) | 0.008 | |||
| 3–8 | 22 (66.7%) | 17 (51.5%) | 5 (15.2%) | – |
| ≥ 9 | 11 (33.3%) | 3 (9.1%) | 8 (24.2%) | |
| Initial Pupil light reflex (n %) | 0.039 | |||
| Both react | 20 (60.6%) | 9 (27.3%) | 11 (33.3%) | |
| 1 reacts | 3 (9.1%) | 2 (6.1%) | 1 (3.0%) | |
| None reacts | 10 (30.3%) | 9 (27.3%) | 1 (3.0%) | |
| Helsinki CT score | 6 ± 3 | 7 ± 2 | 4 ± 3 | 0.013 |
| ICU duration (day) | 8 (6–12) | 9 (8–13) | 7 (3–12) | 0. 079 |
| Hospital discharge (day) | 19 ± 9 | 17 ± 8 | 22 ± 10 | 0.134 |
| Data during ocular ultrasound performed within 6 h after craniectomy | ||||
| ICP (mmHg) | 22 (9–27) | 26 (24–32) | 14 (9–16) | 0.668 |
| MAP (mmHg) | 89 (81–97) | 89 (82–97) | 86 (80–96) | 0.337 |
| CPP (mmHg) | 68 ± 18 | 69 ± 20 | 67 ± 16 | 0.812 |
| Ipsilateral ONSD (mm) | 5.9 ± 0.7 | 6.0 ± 0.7 | 5.8 ± 0.5 | 0.164 |
| Contralateral ONSD (mm) | 5.8 ± 0.7 | 6.1 ± 0.7 | 5.5 ± 0.7 | 0.018 |
CT computerized tomography, ICU intensive care unit, ICP intracranial pressure, MAP mean arterial pressure, CPP cerebral perfusion pressure, ONSD optic nerve sheath diameter, GOS glasgow outcome score, GOS 1 dead, GOS 2 vegetative state, GOS 3 severe disability, GOS 4 moderate disability, GOS 5 back to normal life with or without mild disability
Fig. 3Bilateral ONSD measurements agreement and difference. Bland-Altman plots display the agreement of ipsilateral ONSD and contralateral ONSD measured 3 mm behind the globe by ocular ultrasound. Continuous lines depict the mean of differences; dashed lines denote limits of agreement (mean ± 1.96 times of standard deviation)
Fig. 4Scatter diagrams of bilateral ONSDs and ICP. There was no significant correlation between bilateral ONSDs and ICP respectively (p > 0.05). ONSD optical nerve sheath diameter; ICP intracranial pressure
Parameters in prediction of six months unfavorable outcome (GOS 1–3)
| Cutoff | AUC | 95% CI | Sens/Spec(%) | PPV/NPV(%) | ||
|---|---|---|---|---|---|---|
| Unfavorable outcome (GOS 1–3) | ||||||
| Ipsilateral ONSD (mm) | 6.2 | 0.642 | 0.457–0.801 | 45/84.6 | 81.8/50 | 0.15 |
| 6.5 | 15/100 | 100/43.3 | ||||
| Contralateral ONSD (mm) | 5.5 | 0.717 | 0.534–0.860 | 70/69.2 | 73.7/57.1 | 0.02 |
| 6.6 | 20/100 | 100/44.8 | ||||
| ICP (mmHg) | 17 | 0.638 | 0.453–0.798 | 70/53.9 | 70/53.8 | 0.17 |
| 33 | 10/100 | 100/41.9 | ||||
| Helsinki CT score | 5 | 0.831 | 0.660–0.938 | 85/69.2 | 81/75 | < 0.001 |
|
|
|
| ||||
ONSD optic nerve sheath diameter, ICP intracranial pressure, GOS glasgow outcome score, AUC area under curve, 95% CI 95% confidence intervals, Sens sensitivity, Spec specificity, PPV positive prediction value, NPV negative prediction value