Literature DB >> 18314519

Correlation of visual axis and coronal axis measurements of the optic nerve sheath diameter.

David J Blehar1, Romolo J Gaspari, Anthony Montoya, Richard Calderon.   

Abstract

OBJECTIVE: There are several approaches to sonographic imaging and measurement of the optic nerve sheath diameter (ONSD). In this study, we sought to compare visual axis measurements of the optic nerve sheath (ONS) with traditional coronal axis measurements to assess for correlation.
METHODS: The ONS was visualized in 2 views on both eyes of healthy volunteers using an 8.5-MHz probe. Coronal axis views were obtained with the probe placed at the lateral canthus directed nasally posterior to the globe. Subsequent imaging was made along the midline visual axis. The diameter in this view was measured at several points posterior to the sclera (2, 3, 6, 9, 12, and 15 mm).
RESULTS: Twenty-seven subjects were enrolled (54 scans). There was a significant difference between ONSDs measured in each axis, with a coronal axis mean diameter of 3.4 mm and visual axis mean diameters at 2, 3, 6, 9, 12, and 15 mm of 4.28, 4.32, 5.15, 5.74, 6.39, and 7.42 mm, respectively (P < .05). The Pearson coefficient showed no correlation between coronal axis and visual axis measurements, with R values ranging from 0.51 to 0.69. There was a statistically significant increase in the ONSD as the nerve coursed posteriorly when measured in the visual axis.
CONCLUSIONS: Visual axis measurements do not reliably correlate with coronal axis measurements. The consistently larger diameter measured in the visual axis as well as the gradually increasing diameter posteriorly suggests measurement of an artifactual shadow rather than the true ONS.

Entities:  

Mesh:

Year:  2008        PMID: 18314519     DOI: 10.7863/jum.2008.27.3.407

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  12 in total

1.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

2.  Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure.

Authors:  Ashish Agrawal; Roger Cheng; Julin Tang; Debbie Y Madhok
Journal:  Crit Care Med       Date:  2019-06       Impact factor: 7.598

3.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Rebecca Gray; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

4.  Bedside optic nerve sheath diameter ultrasound for the evaluation of suspected pediatric ventriculoperitoneal shunt failure in the emergency department.

Authors:  M Kennedy Hall; David M Spiro; Alfredo Sabbaj; Christopher L Moore; Katharine L Hopkins; Garth D Meckler
Journal:  Childs Nerv Syst       Date:  2013-06-01       Impact factor: 1.475

5.  Ultrasonographic measurement of the optic nerve sheath diameter and its association with eyeball transverse diameter in 585 healthy volunteers.

Authors:  Dong Hwan Kim; Jin-Sun Jun; Ryul Kim
Journal:  Sci Rep       Date:  2017-11-21       Impact factor: 4.379

Review 6.  Optic Nerve and Cerebral Edema in the Course of Diabetic Ketoacidosis.

Authors:  Łukasz Szmygel; Wojciech Kosiak; Katarzyna Zorena; Małgorzata Myśliwiec
Journal:  Curr Neuropharmacol       Date:  2016       Impact factor: 7.363

7.  Diagnostic and prognostic value of the optic nerve sheath diameter with respect to the intracranial pressure and neurological outcome of patients following hemicraniectomy.

Authors:  Yuzhi Gao; Qiang Li; Chunshuang Wu; Shaoyun Liu; Mao Zhang
Journal:  BMC Neurol       Date:  2018-12-05       Impact factor: 2.474

8.  Using MRI of the optic nerve sheath to detect elevated intracranial pressure.

Authors:  Heidi Harbison Kimberly; Vicki E Noble
Journal:  Crit Care       Date:  2008-09-24       Impact factor: 9.097

9.  Optic Nerve Sheath Diameter Measurement During Diabetic Ketoacidosis: A Pilot Study.

Authors:  Kelly R Bergmann; Donna M Milner; Constantinos Voulgaropoulos; Gretchen J Cutler; Anupam B Kharbanda
Journal:  West J Emerg Med       Date:  2016-07-25

10.  Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter.

Authors:  Uday Yanamandra; Amul Gupta; Sushma Yanamandra; Subrat Kumar Das; Sagarika Patyal; Velu Nair
Journal:  J Neurosci Rural Pract       Date:  2018 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.