Literature DB >> 21550065

Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma.

Aaron Strumwasser1, Rita O Kwan, Louise Yeung, Emily Miraflor, Alex Ereso, Frederico Castro-Moure, Atul Patel, Javid Sadjadi, Gregory P Victorino.   

Abstract

BACKGROUND: Intracranial pressure (ICP) is currently measured with invasive monitoring. Sonographic optic nerve sheath diameter (ONSD) may provide a noninvasive estimate of ICP. Our hypothesis was that bedside ONSD accurately estimates ICP in acutely injured patients. The specific aims were (1) to determine the accuracy of ONSD in estimating elevated ICP, (2) to correlate ONSD and ICP in unilateral and bilateral head injuries, and (3) to determine the effect of ICP monitor placement on ONSD measurements.
MATERIALS AND METHODS: A blinded prospective study of adult trauma patients requiring ICP monitoring was performed at a University-based urban trauma center. The ONSD was measured by ultrasound pre- and post-placement of an ICP monitor (Camino Bolt or Ventriculostomy).
RESULTS: One-hundred fourteen measurements were obtained in 10 trauma patients requiring ICP monitoring. Pre- and post-ONSD were compared with side of injury in the presence of an ICP monitor. ROC analysis demonstrated ONSD poorly estimates elevated ICP (AUC = 0.36). Overall sensitivity, specificity, PPV, NPV, and accuracy for estimating ICP with ONSD were 36%, 38%, 40%, 16%, and 37%. Poor correlation of ONSD to ICP was observed with unilateral (R(2) = 0.45, P < 0.01) and bilateral (R(2) = 0.21, P = 0.01) injuries. ICP monitor placement did not affect ONSD measurements on the right (P = 0.5), left (P = 0.4), or right and left sides combined (P = 0.3).
CONCLUSIONS: Sonographic ONSD as a surrogate for elevated ICP in lieu of invasive monitoring is not reliable due to poor accuracy and correlation.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21550065     DOI: 10.1016/j.jss.2011.03.009

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  29 in total

1.  Optic nerve sheath diameter as criteria for endoscopic third ventriculostomy failure in children.

Authors:  Llewellyn C Padayachy; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2015-06-18       Impact factor: 1.475

2.  Detection and characterization of tree shrew retinal venous pulsations: An animal model to study human retinal venous pulsations.

Authors:  Michael Dattilo; A Thomas Read; Brian C Samuels; C Ross Ethier
Journal:  Exp Eye Res       Date:  2019-06-06       Impact factor: 3.467

3.  Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis.

Authors:  Chiara Robba; Gregorio Santori; Marek Czosnyka; Francesco Corradi; Nicola Bragazzi; Llewellyn Padayachy; Fabio Silvio Taccone; Giuseppe Citerio
Journal:  Intensive Care Med       Date:  2018-07-17       Impact factor: 17.440

4.  Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure.

Authors:  Ashish Agrawal; Roger Cheng; Julin Tang; Debbie Y Madhok
Journal:  Crit Care Med       Date:  2019-06       Impact factor: 7.598

5.  Noninvasive Intracranial Pressure Assessment in Acute Liver Failure.

Authors:  Venkatakrishna Rajajee; Craig A Williamson; Robert J Fontana; Anthony J Courey; Parag G Patil
Journal:  Neurocrit Care       Date:  2018-10       Impact factor: 3.210

Review 6.  Noninvasive methods of detecting increased intracranial pressure.

Authors:  Wen Xu; Patrick Gerety; Tomas Aleman; Jordan Swanson; Jesse Taylor
Journal:  Childs Nerv Syst       Date:  2016-06-28       Impact factor: 1.475

Review 7.  Non-invasive detection of intracranial pressure related to the optic nerve.

Authors:  Jian Li; Chao Wan
Journal:  Quant Imaging Med Surg       Date:  2021-06

8.  Optic nerve ultrasound for the detection of raised intracranial pressure.

Authors:  Venkatakrishna Rajajee; Monique Vanaman; Jeffrey James Fletcher; Teresa Lee Jacobs
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

9.  Intracranial pressure in the American Alligator (Alligator mississippiensis): reptilian meninges and orthostatic gradients.

Authors:  Tatyana Kondrashova; Joshua Blanchard; Lucas Knoche; James Potter; Bruce A Young
Journal:  J Comp Physiol A Neuroethol Sens Neural Behav Physiol       Date:  2019-12-06       Impact factor: 1.836

10.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Rebecca Gray; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475