PURPOSE: To evaluate the diagnostic accuracy of ultrasonography of optic nerve sheath diameter (ONSD) for assessment of intracranial hypertension.
METHODS: Systematic review without language restriction based on electronic databases, with manual review of literature and conference proceedings until July 2010. Studies were eligible if they compared ultrasonography of ONSD with intracranial pressure (ICP) monitoring. Data were extracted independently by three authors. Random-effects meta-analysis and meta-regression were performed.
RESULTS: Six studies including 231 patients were reviewed. No significant heterogeneity was detected for sensitivity, specificity, positive and negative likelihood ratios or diagnostic odds ratio. For detection of raised intracranial pressure, pooled sensitivity was 0.90 [95% confidence interval (CI) 0.80-0.95; p for heterogeneity, p (het) = 0.09], pooled specificity was 0.85 (95% CI 0.73-0.93, p (het) = 0.13), and the pooled diagnostic odds ratio was 51 (95% CI 22-121). The area under the summary receiver-operating characteristic (SROC) curve was 0.94 (95% CI 0.91-0.96).
CONCLUSIONS: Ultrasonography of ONSD shows a good level of diagnostic accuracy for detecting intracranial hypertension. In clinical decision-making, this technique may help physicians decide to transfer patients to specialized centers or to place an invasive device when specific recommendations for this placement do not exist.

Entities:  

Mesh:

Year:  2011        PMID: 21505900     DOI: 10.1007/s00134-011-2224-2

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  57 in total

Review 1.  Outcomes analysis: intracranial pressure monitoring.

Authors:  J E Wilberger
Journal:  Clin Neurosurg       Date:  1997

2.  Quantifying heterogeneity in a meta-analysis.

Authors:  Julian P T Higgins; Simon G Thompson
Journal:  Stat Med       Date:  2002-06-15       Impact factor: 2.373

3.  Echographic correlation of optic nerve sheath size and cerebrospinal fluid pressure.

Authors:  S Galetta; S F Byrne; J L Smith
Journal:  J Clin Neuroophthalmol       Date:  1989-06

4.  Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients.

Authors:  Vivek S Tayal; Matthew Neulander; H James Norton; Troy Foster; Timothy Saunders; Michael Blaivas
Journal:  Ann Emerg Med       Date:  2006-09-25       Impact factor: 5.721

5.  [Diagnosis of elevated intracranial pressure in children with shunt under special consideration of transglobe sonography of the optic nerve].

Authors:  R Brzezinska; R Schumacher
Journal:  Ultraschall Med       Date:  2002-10       Impact factor: 6.548

6.  Relative risks of ventriculostomy infection and morbidity.

Authors:  C G Paramore; D A Turner
Journal:  Acta Neurochir (Wien)       Date:  1994       Impact factor: 2.216

7.  Optic nerve diameters and perimetric thresholds in idiopathic intracranial hypertension.

Authors:  T Salgarello; C Tamburrelli; B Falsini; A Giudiceandrea; A Colotto
Journal:  Br J Ophthalmol       Date:  1996-06       Impact factor: 4.638

8.  Optic nerve sheath ultrasound in the assessment of paediatric hydrocephalus.

Authors:  David McAuley; Anne Paterson; Louise Sweeney
Journal:  Childs Nerv Syst       Date:  2008-09-23       Impact factor: 1.475

9.  A transcranial Doppler method in the evaluation of cerebrovascular spasm.

Authors:  R Aaslid; P Huber; H Nornes
Journal:  Neuroradiology       Date:  1986       Impact factor: 2.804

10.  Predictive value of initial computerized tomography scan, intracranial pressure, and state of autoregulation in patients with traumatic brain injury.

Authors:  Magdalena Hiler; Marek Czosnyka; Peter Hutchinson; Marcella Balestreri; Peter Smielewski; Basil Matta; John D Pickard
Journal:  J Neurosurg       Date:  2006-05       Impact factor: 5.115

View more
  120 in total

1.  Prognostic value of intracranial pressure monitoring for the management of hypertensive intracerebral hemorrhage following minimally invasive surgery.

Authors:  Xiao-Ru Che; Yong-Jie Wang; Hai-Yan Zheng
Journal:  World J Emerg Med       Date:  2020

2.  Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis.

Authors:  Eun Jung Kim; Bon-Nyeo Koo; Seung Ho Choi; Kyoungun Park; Min-Soo Kim
Journal:  Surg Endosc       Date:  2017-06-21       Impact factor: 4.584

3.  Intracranial pressure and its surrogates.

Authors:  Anthony R Frattalone; Robert D Stevens
Journal:  Intensive Care Med       Date:  2011-04-20       Impact factor: 17.440

4.  Impact of controlled intraabdominal pressure on the optic nerve sheath diameter during laparoscopic procedures.

Authors:  Fernando Dip; David Nguyen; Armando Rosales; Morris Sasson; Emanuele Lo Menzo; Samuel Szomstein; Raul Rosenthal
Journal:  Surg Endosc       Date:  2015-04-22       Impact factor: 4.584

5.  Effect of acute high-intensity resistance exercise on optic nerve sheath diameter and ophthalmic artery blood flow pulsatility.

Authors:  W K Lefferts; W E Hughes; K S Heffernan
Journal:  J Hum Hypertens       Date:  2015-03-05       Impact factor: 3.012

6.  Modeling a potential SANS countermeasure by experimental manipulation of the translaminar pressure difference in mice.

Authors:  Guofu Shen; Schuyler S Link; Xiaofeng Tao; Benjamin J Frankfort
Journal:  NPJ Microgravity       Date:  2020-07-31       Impact factor: 4.415

7.  Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis.

Authors:  Chiara Robba; Gregorio Santori; Marek Czosnyka; Francesco Corradi; Nicola Bragazzi; Llewellyn Padayachy; Fabio Silvio Taccone; Giuseppe Citerio
Journal:  Intensive Care Med       Date:  2018-07-17       Impact factor: 17.440

8.  Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure.

Authors:  Ashish Agrawal; Roger Cheng; Julin Tang; Debbie Y Madhok
Journal:  Crit Care Med       Date:  2019-06       Impact factor: 7.598

9.  Higher optic nerve sheath diameters are associated with lower ocular blood flow velocities in glaucoma patients.

Authors:  Koen Willekens; Luís Abegão Pinto; Evelien Vandewalle; Carlos Marques-Neves; Ingeborg Stalmans
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-11-27       Impact factor: 3.117

10.  Association between optic nerve sheath diameter and mortality in patients with severe traumatic brain injury.

Authors:  Mypinder S Sekhon; Paul McBeth; Jie Zou; Lu Qiao; Leif Kolmodin; William R Henderson; Steve Reynolds; Donald E G Griesdale
Journal:  Neurocrit Care       Date:  2014-10       Impact factor: 3.210

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.